Growatt · manufacturer profile
The APX HV stack and the ALP LV packs
Inverter manufacturer
Updated 2 November 2026 · Checked against Growatt's Australian warranty cards and datasheets, the CEC register (16 November 2026) and Synergy's list (30 October 2026) · By Solar Battery Perth
In short
Growatt makes hybrid inverters and two home batteries built in 5 kWh steps, both with LFP cells (lithium iron phosphate). The APX HV stacks 5 kWh modules under a Growatt power module, from 5 to 30 kWh, in a single-phase and a three-phase version. The ALP LV stacks 5 kWh packs on a wall or floor, from 5 to 50 kWh. Both carry a 10-year warranty while the system stays on Growatt's monitoring platform, and 3 years without it. Growatt New Energy Australia Pty Ltd in Silverwater, New South Wales, is the Australian company on the warranty cards. A battery system needs an inverter with a battery-storage (DER-Storage) listing on Synergy's Supported Solutions List to be eligible for the WA Battery Scheme. Other scheme conditions apply. The MOD-XH and MID-XH hybrids the three-phase APX datasheet names were on Synergy's list dated 30 October 2026, with the WA scheme flag. A three-phase APX on one of them pairs with an inverter listed for battery storage on Synergy's list. The MIN TL-XH2 hybrid the single-phase APX manual names was on the same list with the WA scheme flag. A single-phase APX on it pairs with an inverter listed for battery storage on Synergy's list. The SPM and SPH TL-HUB hybrids Growatt's inverter documents pair with the ALP were on the same list with the WA scheme flag. An ALP on one of them pairs with an inverter listed for battery storage on Synergy's list.
Specifications and pricing change. Confirm them with the manufacturer.
The company
Growatt says it was founded in Shenzhen in 2011 and set up its Australian arm the same year. Inverters came first, by Growatt's own account: a 5000MTL inverter in 2012, then home storage in 2015 and the ARK modular battery in 2020. In 2025, Growatt says, it launched an APX 2.0 battery alongside new MOD-XU and MID-HU hybrids. None of those 2025 products has a row on the Australian register yet, so the batteries on this page are the APX and the ALP.
The warranty behind both batteries is given by Growatt New Energy Technology Co., Ltd in Shenzhen. The Australian company on the cards is Growatt New Energy Australia Pty Ltd, at Silverwater in New South Wales. The older ALP card and the 2024 terms print a Homebush West address for the same company. So the current card is the one to keep.
Report a fault within 14 days to the supplier, usually your installer. The installer or the owner then sends Growatt's claim form, within a month of the fault. Growatt New Energy Australia is the local company on the card.
From Growatt's Australian APX battery warranty card, dated 12 February 2026.
Two batteries, two ways to stack 5 kWh. The APX grows in both directions on a three-phase supply: every module adds storage and adds output, up to 30 kWh and 15 kW at six modules. The ALP holds more, up to 50 kWh in ten packs. Its output settles from two packs up: 5 kW on the E1 and 6.5 kW on the E2.
The APX also takes new modules beside old ones. Both Australian APX datasheets say modules at different ages and charge levels can share one system, because each module manages its own energy. The ALP manual is stricter: packs in one stack come from the same batch and model, and an old pack is never mixed with a new one.
The warranty has one condition that matters more than the rest. The 10 years only hold while the system is monitored on Growatt's platform. Without that monitoring the battery warranty is 3 years. So the internet connection is part of the product.
The Clean Energy Council (CEC) approved both Australian APX versions on 23 April 2026, listed to 31 December 2027. On those rows the usable capacity equals the nominal 5 kWh a module. Older APX rows from 2023 and 2024 sit on the register under codes without the AU suffix, at 90% usable. Two of them were listed only to 1 November and 30 November 2026. So a quote carrying one of those older codes needs a fresh check that it is still listed. The ALP E1 packs were approved on 12 September 2025, and the two largest sizes on 5 February 2026. The E2 followed on 16 January 2026. All are listed to 31 December 2027. Growatt's hybrids on the register are the single-phase MIN TL-XH2, SPH TL-HU, SPH TL-HUB and SPM TL-HU, and the three-phase MOD-XH and MID-XH. The first-generation MIN 2500-6000TL-XH rows ended on 8 January 2025. That matters in the pairing chapter below.
APX 5.0P-S0 AU to 30.0P-S0 AU: one to six 5 kWh modules, 5 to 30 kWh. Output 2.5 kW at one module and 6.2 kW from three up. IP66, wall or floor
CEC approved
APX 5.0P-S2 AU to 30.0P-S2 AU: one to six 5 kWh modules, 5 to 30 kWh. Output 2.5 to 15 kW, rising with every module. IP66, wall or floor
CEC approved
ALP 5.0L-E1 to 50.0L-E1: one to ten 5 kWh packs, 5 to 50 kWh, 3.5 kW at one pack and 5 kW from two up, IP66
CEC approved
ALP 5.0L-E2 to 50.0L-E2: one to ten 5 kWh packs, 5 to 50 kWh, 3.5 kW at one pack and 6.5 kW from two up, IP66
CEC approved
The APX is a column. Up to six 5 kWh LFP modules stack under a Growatt power module, the unit that controls the stack, on a base or a wall bracket. Each module weighs 50 kg and is 690 mm wide. A one-module three-phase system weighs 68 kg and stands 660 mm tall. Six modules weigh 318 kg and stand over two metres, so the 25 and 30 kWh sizes split into two columns side by side.
The two versions differ in output. The three-phase S2 AU gives 2.5 kW with one module and adds 2.5 kW per module, up to 15 kW at six. For 60 seconds it can give more: 4 kW with one module and 20 kW with five or six. The single-phase S0 AU gives 2.5 kW with one module, 5 kW with two and 6.2 kW from three up, with a 60-second peak of 10 kW. So on a single-phase supply, modules four to six add storage and not output.
On the Australian datasheets the full 5 kWh of each module is usable. That is 100% depth of discharge (the share of the battery the system lets you use). The three-phase manual rates the module at 4,800 cycles at 25 °C, down to 60% of capacity. The single-phase documents we read give no cycle figure. Neither version prints a round-trip efficiency.
Both versions are rated IP66, which is dust-tight and sealed against strong water jets, and go on a wall or the floor. The datasheets give an operating range of -10 to 50 °C. The warranty card asks for more than the rating suggests: no outdoor use without proper shelter, and never under direct sunlight.
The ALP is a stack of low-voltage 5 kWh LFP packs, up to ten in parallel on a floor base or a wall mount. Each pack is 44 kg and 295 mm tall. Two packs make 10 kWh at 88 kg, and ten make 50 kWh at 440 kg, standing just under three metres. A stack that tall belongs on a floor.
Output settles early. One pack gives 3.5 kW. From two packs up, the E1 gives 5 kW, with a 6.2 kW maximum, whatever the size. The E2 does the same at 6.5 kW, with a 7.5 kW maximum. So the ALP is the battery for a home that wants more hours of storage rather than more kilowatts at once.
Growing an ALP has rules. The manual says packs in one stack come from the same batch, model and maker. An old pack is never mixed with a new one, and a pack under 300 cycles counts as new. An added pack goes in within a year of the first, and within its own six-month shelf life. So the first quote should carry the size the household expects to need.
The packs are rated IP66 and the manual allows indoor or outdoor installation. Outdoors, the manual asks for an awning to keep off direct sun and rain. The operating range is -10 to 50 °C, with 15 to 30 °C recommended. The warranty card for the E1 is tighter, at 0 to 45 °C at all times. No ALP document we read gives a cycle rating or a round-trip efficiency.
It depends on the supply. The three-phase APX datasheet names four inverter lines as compatible: MOD 3-10KTL3-XH, MID 11-30KTL3-XH, MOD 3-15KTL3-HU and MID 29.9-50KTL3-HU. The single-phase APX datasheet names one: the MIN 2500-6000TL-XH. That is the first-generation MIN, whose register rows ended on 8 January 2025. The single-phase APX manual pairs it with both the MIN TL-XH and the newer MIN TL-XH2, which is on the register today. The MIN TL-XH2 datasheet also lists the APX HV as a compatible battery.
The battery voltage tells the same story. The single-phase version runs at 450 V nominal, between 380 and 550 V. The three-phase version runs at 650 V, between 600 and 980 V. The two are not interchangeable, so the quote has to name the version that matches the home's supply.
The ALP datasheet has no compatible-inverter row. Its manual names the inverter only as the unit it talks to. Growatt's inverter documents name the ALP instead: the single-phase SPM 8000-10000TL-HU datasheet takes the ALP 5.0L-E1 or E2, and the SPH TL-HUB and SPA TL-AUB documents call for the ALP 5.0L-E1. The APX warranty card also says the battery is covered only with Growatt storage devices.
Both batteries use cobalt-free LFP cells and carry an IP66 enclosure. Beyond that, the documents we read say little. The ALP E2 datasheet lists an aerosol unit and a heating film without describing either. No other Growatt document we read describes a fire suppression system, a cell-level safety design or a backup switch time.
Both batteries carry 10 years from the date of purchase, and no more than 10 years and 3 months from the day Growatt delivers them. The warranty does not transfer to a new owner. The 10 years hold only while the system is monitored on Growatt's platform. Without that, the battery warranty is 3 years. Ten years is also the term the federal energy department says many battery makers offer.
The capacity promise is split in two. The Australian APX card is dated 12 February 2026. On it, the battery keeps at least 70% of its nominal energy for the first 5 years, then at least 50% for the next 5. The ALP card for the 5 to 40 kWh E1 sizes promises 70% then 60%. Both cards cap use at 300 full discharges a year, and measure it against 1,350 kWh a year for each 5 kWh module (300 discharges of 90%). Above that the warranted energy drops, and a drop past 30% ends the performance warranty.
One thing to know. Growatt's 2024 Australian battery terms print different figures: 70% for all 10 years, a 14.9 MWh (megawatt-hour) energy allowance per 5 kWh module, and shorter windows for installing and claiming. The cards above name the Australian APX and ALP system codes, while the 2024 terms name only the module and controller codes. So this page follows the cards. The card that comes with the quote is the one that governs it. No card we read names the 45 and 50 kWh E1 sizes or the E2 packs, so ask Growatt which terms cover those.
Four conditions matter most. The battery is installed within 6 months of leaving Growatt, and a claim form goes in within a month of the fault. The APX stays under shelter and out of direct sun, with the air around it between -10 and 50 °C at all times. The ALP card is tighter, at 0 to 45 °C at all times. The APX card also covers the battery only with Growatt storage devices.
The installer or the owner lodges a claim with Growatt, online at warranty.growatt.com or by email. The APX card says its terms are governed by the law of the People's Republic of China, in Shenzhen. It also carries the Australian Consumer Law guarantee statement. So your consumer guarantees apply regardless.
On the Australian cards, 10 years, with 70% of nominal energy promised for the first 5 and 50% (APX) or 60% (ALP E1) for the next 5. That holds at up to 300 full discharges a year. The three-phase APX manual adds a lab figure of 4,800 cycles at 25 °C, down to 60% of capacity. The single-phase APX and the ALP carry no cycle figure in the documents we read.
Showing: Western Australia, Synergy network. Other states: not covered yet
A battery system needs an inverter with a battery-storage (DER-Storage) listing on Synergy's Supported Solutions List to be eligible for the WA Battery Scheme. Other scheme conditions apply. The MOD-XH and MID-XH hybrids the three-phase APX datasheet names were on Synergy's list dated 30 October 2026, with the WA scheme flag. A three-phase APX on one of them pairs with an inverter listed for battery storage on Synergy's list. The MIN TL-XH2 hybrid the single-phase APX manual names was on the same list with the WA scheme flag. A single-phase APX on it pairs with an inverter listed for battery storage on Synergy's list. The SPM and SPH TL-HUB hybrids Growatt's inverter documents pair with the ALP were on the same list with the WA scheme flag. An ALP on one of them pairs with an inverter listed for battery storage on Synergy's list.
Synergy's list names inverters, not batteries. So a Growatt battery counts through the hybrid on the quote. For a single-phase home, the APX datasheet names the first-generation MIN TL-XH and the APX manual adds the MIN TL-XH2.
Growatt's inverters on Synergy's list are marked activation-ready for a Synergy VPP program (list dated 30 October 2026). The scheme also asks the household to join a virtual power plant (VPP). That is a program that lets a retailer call on home batteries when the grid needs them. Synergy's own VPP is Battery Rewards. A VPP run by the battery supplier is an allowed alternative, under the scheme's conditions. No Growatt document we read names a VPP its batteries join in WA. So that is a question for the installer.
The rest of the scheme's conditions are set out on our WA battery rebate page, and our Synergy approved products guide shows how to read the list.
Growatt says it launched an APX 2.0 battery in 2025, with new MOD-XU and MID-HU hybrids. No APX 2.0 row was on the CEC battery register in our 20 October 2026 snapshot, and no MOD-HU or MID-HU row was on Synergy's list dated 30 October 2026. So for a Perth buyer the APX 2.0 is not yet on the register, and the APX on a quote today is the range above.
A Growatt battery is sized in 5 kWh steps, and the home's supply decides which one. On three-phase, the APX adds output with every module and takes new modules beside old. On single-phase, the APX output stops at 6.2 kW and runs on a MIN TL-XH or TL-XH2 hybrid. The ALP holds up to 50 kWh and runs at 5 or 6.5 kW. Both need Growatt's monitoring to keep the 10-year warranty, and both need shelter from direct sun. A battery system needs an inverter with a battery-storage (DER-Storage) listing on Synergy's Supported Solutions List to be eligible for the WA Battery Scheme. Other scheme conditions apply. The MOD-XH and MID-XH hybrids the three-phase APX datasheet names were on Synergy's list dated 30 October 2026, with the WA scheme flag. A three-phase APX on one of them pairs with an inverter listed for battery storage on Synergy's list. The MIN TL-XH2 hybrid the single-phase APX manual names was on the same list with the WA scheme flag. A single-phase APX on it pairs with an inverter listed for battery storage on Synergy's list. The SPM and SPH TL-HUB hybrids Growatt's inverter documents pair with the ALP were on the same list with the WA scheme flag. An ALP on one of them pairs with an inverter listed for battery storage on Synergy's list.
Ask for the battery version (S0 AU or S2 AU, or E1 or E2) and the inverter, each by model code, in writing. In our 20 October 2026 snapshot of the CEC register, the Australian APX rows and every ALP row are listed to 31 December 2027. The older APX S1 row without the AU suffix was listed only to 1 November 2026, and the S2 row only to 30 November 2026. On Synergy's list dated 30 October 2026, the MIN TL-XH2, SPM, SPH TL-HUB, MOD-XH and MID-XH hybrids carry the WA scheme flag.
Solar Battery Perth is independent. We're not owned by an energy retailer or a manufacturer. Installers quote the actual price.
For checking
| Warranty | 10 years on the APX HV and ALP LV while monitored, 3 years withoutGrowatt's Australian battery warranty cards |
|---|---|
| Batteries | LFP (lithium iron phosphate), 4.5-50 kWh usable |
| Approved now | 44 batteries and 53 inverters on the CEC (Clean Energy Council) register |
| Support in Australia | Office. Contact details |
| Local support | Yes, support handled through Australian channelsSource: Australian warranty, checked 8 Oct 2026Confirmed |
| CEC listings | 97 approved right now · 86 delistedApproved |
| Documents |
Each product type at a glance. The full lists, grouped by series, are below.
Pick a type to open its full list, grouped by series.
Grouped by series. Open a series for each variant, or a model for full specs.
44 CEC-approved batteries, 7 not currently listed · grouped into 3 series · showing first 50 of 51
APX 10.0P-S0
APX 10.0P-S0 AU
APX 10.0P-S2
APX 10.0P-S2 AU
APX 15.0P-S0
APX 15.0P-S0 AU
APX 15.0P-S2
APX 15.0P-S2 AU
APX 20.0P-S0
APX 20.0P-S0 AU
APX 20.0P-S2
APX 20.0P-S2 AU
APX 25.0P-S0
APX 25.0P-S0 AU
APX 25.0P-S2
APX 25.0P-S2 AU
APX 30.0P-S0
APX 30.0P-S0 AU
APX 30.0P-S2
APX 30.0P-S2 AU
APX 5.0P-S0
APX 5.0P-S0 AU
APX 5.0P-S2
APX 5.0P-S2 AU
APX 10.0P-S1
APX 15.0P-S1
APX 20.0P-S1
APX 25.0P-S1
APX 30.0P-S1
APX 5.0P-S1
Based on manufacturer specifications and CEC-approved configurations. Always confirm system design with your installer.
Grouped by series. Open a series for each variant, or a model for full specs.
53 CEC-approved inverters, 79 not currently listed · grouped into 9 series · showing first 50 of 132
MIN 10000TL-X2 (AS4777-2 2020)
MIN 2500TL-XH2 (AS4777-2 2020)
MIN 3000TL-XH2 (AS4777-2 2020)
MIN 3600TL-XH2 (AS4777-2 2020)
MIN 4200TL-XH2 (AS4777-2 2020)
MIN 4600TL-XH2 (AS4777-2 2020)
MIN 5000TL-XH2 (AS4777-2 2020)
MIN 6000TL-XH2 (AS4777-2 2020)
MIN 7000TL-X2 (AS4777-2 2020)
MIN 8000TL-X2 (AS4777-2 2020)
MIN 9000TL-X2 (AS4777-2 2020)
MIN 10000TL-X (AS4777-2 2020)
MIN 2500TL-X (AS4777-2 2020)
MIN 2500TL-XA (AS4777-2 2020)
MIN 2500TL-XH (AS4777-2 2020)
MIN 3000TL-X (AS4777-2 2020)
MIN 3000TL-XA (AS4777-2 2020)
MIN 3000TL-XH (AS4777-2 2020)
MIN 3600TL-X (AS4777-2 2020)
MIN 3600TL-XA (AS4777-2 2020)
MIN 3600TL-XH (AS4777-2 2020)
MIN 4200TL-X (AS4777-2 2020)
MIN 4200TL-XA (AS4777-2 2020)
MIN 4200TL-XH (AS4777-2 2020)
MIN 4600TL-X (AS4777-2 2020)
MIN 4600TL-XA (AS4777-2 2020)
MIN 4600TL-XH (AS4777-2 2020)
MIN 5000TL-X (AS4777-2 2020)
MIN 5000TL-XA (AS4777-2 2020)
MIN 5000TL-XH (AS4777-2 2020)
MIN 6000TL-X (AS4777-2 2020)
MIN 6000TL-XA (AS4777-2 2020)
MIN 6000TL-XH (AS4777-2 2020)
MIN 7000TL-X (AS4777-2 2020)
MIN 7000TL-X(E) (AS4777-2 2020)
MIN 8000TL-X (AS4777-2 2020)
MIN 8000TL-X(E) (AS4777-2 2020)
MIN 9000TL-X (AS4777-2 2020)
What has happened to Growatt on the CEC register.
Each block is one register event. Tap a year to see its events in the list below.
ARK Battery Series Launch
Modular LFP battery system for residential applications
⚡ 20 Inverter Models Listed
Inverter range expanded to 20 CEC-approved models.
⚡ 50 Inverter Models Listed
Inverter range expanded to 50 CEC-approved models.
ACCC recall: SPH Series Solar Power Inverters
The Emergency Power Supply (EPS) port plug can be removed by hand without a tool. If the plug is removed or not connected during installation, there is access to live hazardous voltage, with a risk of serious injury or death from electric shock.
🔋 50 Battery Listings
Battery range expanded to 50 CEC-approved listings.
On the APX, yes. Both Australian datasheets allow new and old modules in one system, up to six in a column. On the ALP the manual is strict: same batch and model, no old pack beside a new one, and the added pack goes in within a year of the first.
Yes, for the full warranty. The 10 years hold only while the system is monitored on Growatt's platform, and without that the battery warranty is 3 years.
Under shelter, yes. Both batteries are rated IP66, and the ALP manual allows outdoor use with an awning. The warranty cards exclude outdoor use without proper shelter and any spot in direct sun. The APX card allows -10 to 50 °C and the ALP E1 card 0 to 45 °C, at all times.
The Australian cards promise 70% of nominal energy for 5 years, then 50% (APX) or 60% (ALP E1) for another 5, at up to 300 full discharges a year. The three-phase APX manual rates the module at 4,800 cycles in the lab, which is not a warranty term.
Growatt's home batteries use LFP cells. LFP (lithium iron phosphate) is the most common residential chemistry in WA for its long cycle life and stability in Perth's heat.
Solar Battery Perth lists 44 CEC-approved Growatt battery models with specs, indicative pricing and warranty detail. Compare them against other brands to find the best fit for your Perth home.
Growatt has 53 CEC-approved inverter models from 2.5-29.9 kW (single and three phase). Compare them against other brands by size, phase and battery compatibility.
Growatt's 53 inverter models include 27 hybrid and 10 battery inverters, which connect a home battery directly. Confirm which batteries each model supports with your installer.
Are you Growatt?
Help us keep this profile up to date.
How the WA Battery Scheme works, and why eligibility follows the inverter on the quote.
What Synergy's Supported Solutions List covers, and how our inverter library shows which models are on it.
How the inverter paired with a battery sets its charge rate, discharge rate and backup power.
The product safety alerts we track for home batteries and inverters, brand by brand.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.
Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.