Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Growatt
  4. MIN 6000TL-XH2

Hybrid inverter · Growatt · CEC approved July 2024

Growatt MIN 6000TL-XH2

CEC listing: MIN 6000TL-XH2 (AS4777-2 2020)

A 6 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
6kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MIN 6000TL-XH2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6kW
How much solar it can turn into usable power at once
Max efficiency
98.4%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Shenzhen Growatt New Energy Co Ltd stands behind it

Full datasheet

Every figure on file for the Growatt MIN 6000TL-XH2, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power2.5 kW
Efficiency
Max efficiency98.4%
European efficiency97.1%
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
10 July 2024
Approval expiry
10 July 2027
Status
Active
Listed for STCs
Yes

About Growatt

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
132
CEC-approved batteries
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
25.5 kWh
Annual yield
9,308 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.growatt.com.au
12 years on the CEC list

How it compares

The Growatt MIN 6000TL-XH2 against the closest-power inverters from other brands.

Specification
Growatt MIN 6000TL-XH2Growatt
Energizer FORCE 6.0HSEnergizer
Energizer Force 6.0HT+Energizer
Rated power?6 kW6 kW6 kW
Max efficiency?98.4%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Growatt MIN 6000TL-XH2

The warranty covers defects in materials and workmanship for a period of 10 years, but excludes damages due to improper installation or use. To make a claim, contact customer service with your inverter's serial number and description of the issue.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modification of the inverter, or operating conditions outside specified parameters.
Environment limits
None stated.
Read the official warranty document (PDF)

Fault & error codes — Growatt MIN 6000TL-XH2

From the install manual

10 documented

Showing 10 of 10. The official install manual is the authoritative source — always confirm before acting.

  • 200criticalCall your installer
    Manual (PDF)

    AFCI Tripped

    Likely cause
    An electric arc has occurred in the PV system
    What to do
    Disconnect all power supply connections to the inverter. Turn off the battery input switch; turn off the inverter's AC output breaker; turn the inverter's PV input DC switch to the position 'OFF', and wait until the error message disappears.
  • 425criticalCall your installer
    Manual (PDF)

    AFCI Self-Test Failed

    Likely cause
    AFCI self-test is unsuccessful
    What to do
    Disconnect all power supply connections to the inverter and contact Growatt.
  • 201warningCall your installer
    Manual (PDF)

    Residual I High

    Likely cause
    Leakage current is excessively high
    What to do
    Restart the inverter. If the error message still exists, contact Growatt.
  • 202warningCall your installer
    Manual (PDF)

    PV Voltage High

    Likely cause
    The DC input voltage exceeds the specified upper threshold
    What to do
    Disconnect the DC switch immediately. Check the voltage of each PV string with a multimeter. If the voltage of PV string is lower than 550V, contact Growatt.
  • 203warningCall your installer
    Manual (PDF)

    PV Insulation Resistance Low

    Likely cause
    Insulation problem
    What to do
    Check if the panel enclosure is grounded properly. Check if the inverter is grounded properly. Check if the DC breaker gets wet. Check the impedance between PV(+) and PV(-) and the ground, which must be more than 25KΩ or 550KΩ according to VDE0126 standards. If the error message persists, contact Growatt.
  • 300warningCall your installer
    Manual (PDF)

    AC V Outrange

    Likely cause
    Utility grid voltage is out of permissible range
    What to do
    Switch off the DC switch. Check the AC wiring, especially the neutral and ground wire. Check if the grid voltage complies with local grid standard. Restart the inverter, if the problem persists, contact Growatt.
  • 302warning
    Manual (PDF)

    No AC Connection

    Likely cause
    No AC connection
    What to do
    Check AC wiring. Check the status of the AC breaker.
  • 303warningCall your installer
    Manual (PDF)

    PE Abnormal

    Likely cause
    The voltage difference between the Neutral and PE is above 30V
    What to do
    Check the voltage of Neutral and PE cables. Check AC wiring. Restart the inverter, if the error message persists, contact Growatt.
  • 304warningCall your installer
    Manual (PDF)

    AC F Outrange

    Likely cause
    Utility grid frequency is out of permissible range
    What to do
    Switch off the DC switch. Check the AC wiring, especially the neutral and ground wires. Check if the grid frequency complies with local grid standard. Restart the inverter, if the problem persists, contact Growatt.
  • 407warningCall your installer
    Manual (PDF)

    Auto Test Failure

    Likely cause
    Self-test fails
    What to do
    Restart the inverter, repeat the Auto Test, if the problem persists, contact Growatt.

More Shenzhen Growatt New Energy Co Ltd inverters

Growatt SPH6000 (AS4777-2 2020)

6 kW · 1φ

MIN 6000TL-X (AS4777-2 2020)

6 kW · 1φ

MIN 6000TL-XA (AS4777-2 2020)

6 kW · 1φ

MIN 6000TL-XH (AS4777-2 2020)

6 kW · 1φ

MOD 6000TL3-X (AS4777-2 2020)

6 kW · 1φ

SPA 6000TL-AU (AS4777-2 2020)

6 kW · 1φ

View all Shenzhen Growatt New Energy Co Ltd inverters

More from Growatt

Other CEC-approved products from Growatt available in Australia.

Growatt Batteries

ALP 10.0L-E1

10 kWh · LFP

ALP 10.0L-E2

10 kWh · LFP

ALP 15.0L-E1

15 kWh · LFP

ALP 15.0L-E2

15 kWh · LFP

ALP 20.0L-E1

20 kWh · LFP

ALP 20.0L-E2

20 kWh · LFP

View all Growatt batteries
View full Growatt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?