Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Growatt
  4. MIN 9000TL-X2

Solar inverter · Growatt · CEC approved September 2024

Growatt MIN 9000TL-X2

CEC listing: MIN 9000TL-X2 (AS4777-2 2020)

A 9 kW single-phase solar inverter.

Rated power
9kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MIN 9000TL-X2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
9kW
How much solar it can turn into usable power at once
Max efficiency
98.1%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
10yr
How long Shenzhen Growatt New Energy Co Ltd stands behind it

Full datasheet

Every figure on file for the Growatt MIN 9000TL-X2, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power7 kW
Efficiency
Max efficiency98.1%
Physical
Weight18.2 kg
IP ratingIP66
Operating temperature-30°C to 60°C
Installation requirements
Cable gauge6 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
2 Sept 2024
Approval expiry
2 Sept 2027
Status
Active
Listed for STCs
Yes

About Growatt

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
132
CEC-approved batteries
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
38.3 kWh
Annual yield
13,961 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.growatt.com.au
12 years on the CEC list

How it compares

The Growatt MIN 9000TL-X2 against the closest-power inverters from other brands.

Specification
Growatt MIN 9000TL-X2Growatt
Energizer Force 9.0HS+Energizer
Energizer Force 9.0SEnergizer
Rated power?9 kW9 kW9 kW
Max efficiency?98.1%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Growatt MIN 9000TL-X2

This warranty covers manufacturing defects for a period of 10 years. To make a claim, please contact Growatt customer service with the relevant details.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, and damage due to moisture or dust penetration
Environment limits
None specified
Read the official warranty document (PDF)

Fault & error codes — Growatt MIN 9000TL-X2

From the install manual

9 documented

Showing 9 of 9. The official install manual is the authoritative source — always confirm before acting.

  • 203criticalCall your installer
    Manual (PDF)

    PV Isolation Low

    Likely cause
    Insulation problem
    What to do
    1. Check if the panel enclosure is grounded properly. 2. Check if the inverter is grounded properly. 3. Check if the DC breaker gets wet. 4. Check the impedance of PV(+) & PV(-) between ground (must be more than 30KΩ), if the error message displays despite passing checks, contact Growatt.
  • 407critical
    Manual (PDF)

    Auto Test Failed

    Likely cause
    Auto test didn't pass
    What to do
    Restart inverter, repeat auto test; if the problem continues, contact Growatt.
  • 200warningCall your installer
    Manual (PDF)

    AFCI fault

    Likely cause
    High power discharge of electricity between two or more conductors
    What to do
    1. After shutdown, check the connection of PV terminals. 2. Restart the inverter. 3. If the error message still exists, contact Growatt.
  • 201warningCall your installer
    Manual (PDF)

    Residual I High

    Likely cause
    Leakage current too high
    What to do
    1. Restart the inverter. 2. If the error message still exists, contact Growatt.
  • 202warningCall your installer
    Manual (PDF)

    PV Voltage High

    Likely cause
    The DC input voltage is exceeding the maximum tolerable value
    What to do
    1. Disconnect the DC switch immediately. 2. Check the voltage of each PV string with a multimeter. 3. If the voltage of the PV string is lower than expected, contact Growatt.
  • 300warningCall your installer
    Manual (PDF)

    AC V Outrange

    Likely cause
    Utility grid voltage is out of permissible range
    What to do
    1. Please switch off the DC switch. 2. Check AC wiring, especially neutral and ground wire. 3. Check grid voltage to ensure it complies with local grid standard. Restart the inverter; if the problem persists, contact Growatt.
  • 303warningCall your installer
    Manual (PDF)

    PE abnormal

    Likely cause
    Voltage of Neutral and PE above 30V
    What to do
    1. Check the voltage of Neutral and PE. 2. Check AC wiring. 3. Restart inverter; if the error message still exists, contact the manufacturer.
  • 304warningCall your installer
    Manual (PDF)

    AC F Outrange

    Likely cause
    Utility grid frequency out of permissible range
    What to do
    1. Please switch off the DC switch. 2. Check AC wiring, especially neutral and ground wire. 3. Check grid frequency; if the issue persists, contact Growatt.
  • 302info
    Manual (PDF)

    No AC connection

    Likely cause
    No AC connection
    What to do
    1. Check AC wiring. 2. Check the status of the AC breaker.

More Shenzhen Growatt New Energy Co Ltd inverters

MIN 9000TL-X (AS4777-2 2020)

9 kW · 1φ

MOD 9000TL3-X-AU (AS4777-2 2020)

9 kW · 1φ

MIN 10000TL-X2 (AS4777-2 2020)

9.99 kW · 1φ

SPM 10000TL-HU (AS4777-2 2020)

9.999 kW · 1φ

MIN 8000TL-X (AS4777-2 2020)

8 kW · 1φ

MIN 8000TL-X(E) (AS4777-2 2020)

8 kW · 1φ

View all Shenzhen Growatt New Energy Co Ltd inverters

More from Growatt

Other CEC-approved products from Growatt available in Australia.

Growatt Batteries

ALP 10.0L-E1

10 kWh · LFP

ALP 10.0L-E2

10 kWh · LFP

ALP 15.0L-E1

15 kWh · LFP

ALP 15.0L-E2

15 kWh · LFP

ALP 20.0L-E1

20 kWh · LFP

ALP 20.0L-E2

20 kWh · LFP

View all Growatt batteries
View full Growatt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?