Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Ningbo Sunways Technologies
  4. STT-5KTL

Solar inverter · Ningbo Sunways Technologies · CEC approved March 2026

Ningbo Sunways Technologies STT-5KTL

CEC listing: STT-5KTL (AS4777-2 2020)

A 5 kW three-phase solar inverter.

Rated power
5kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

STT-5KTL: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
98.1%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Solar
Runs solar only
Warranty
5yr
How long Ningbo Sunways Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Ningbo Sunways Technologies STT-5KTL, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.1%
European efficiency98.2%
Physical
IP ratingIP65
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker20 A
Cable gauge4 mm²
Earthing methodPE
DNSP pre-approvalNo
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
4 Mar 2026
Approval expiry
20 July 2027
Status
Active
Listed for STCs
Yes

About Ningbo Sunways Technologies

Years on the CEC list
4 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The Ningbo Sunways Technologies STT-5KTL against the closest-power inverters from other brands.

Specification
Ningbo Sunways Technologies STT-5KTLNingbo Sunways Technologies
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?98.1%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Ningbo Sunways Technologies STT-5KTL

The warranty covers defects for 5 years. It excludes damages from non-authorized modification and must be claimed with the original purchase receipt.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, tampering, use of non-Sunways components or firmware.
Environment limits
Damages caused by unpredictable factors such as earthquake, stormy weather, flood, lightning, fire and pests.
Read the official warranty document (PDF)

Fault & error codes — Ningbo Sunways Technologies STT-5KTL

From the install manual

19 documented

Showing 19 of 19. The official install manual is the authoritative source — always confirm before acting.

  • AC Transducer FaultcriticalCall your installer
    Manual (PDF)

    AC transducer anomaly.

    Likely cause
    Possible electronic failure.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • Bus Voltage FaultcriticalCall your installer
    Manual (PDF)

    BUS voltage is over-high.

    Likely cause
    Investigate potential issues causing high bus voltage.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • DCI FaultcriticalCall your installer
    Manual (PDF)

    DC Injection High.

    Likely cause
    Higher DC component in AC output.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • E2 FaultcriticalCall your installer
    Manual (PDF)

    Internal storage anomaly.

    Likely cause
    Could be caused by a strong external magnetic field.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • Flash FaultcriticalCall your installer
    Manual (PDF)

    Internal storage anomaly.

    Likely cause
    Could be caused by a strong external magnetic field.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • GFCI Device FaultcriticalCall your installer
    Manual (PDF)

    GFCI device anomaly.

    Likely cause
    Possible electronic failure.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • GFCI FaultcriticalCall your installer
    Manual (PDF)

    Excessive leakage current.

    Likely cause
    The ground current is too high or PV cable has a short circuit to ground.
    What to do
    Check PV cable for shorts to ground.
  • Grid Frequency FaultcriticalCall your installer
    Manual (PDF)

    Grid over frequency or under-frequency.

    Likely cause
    Check whether the safety regulation settings are correct. Check the frequency of the grid.
    What to do
    Contact local grid company for resolution.
  • Grid Voltage FaultcriticalCall your installer
    Manual (PDF)

    Grid overvoltage or undervoltage.

    Likely cause
    Check whether the safety regulation setting is correct. Check the voltage of the grid.
    What to do
    Contact local grid company for resolution.
  • Relay Check FailcriticalCall your installer
    Manual (PDF)

    Self-checking of relay fails.

    Likely cause
    Neutral & ground cables are not connected well on AC side.
    What to do
    Check connections between neutral and ground.
  • SCI FaultcriticalCall your installer
    Manual (PDF)

    Internal communication fails.

    Likely cause
    Could be caused by a strong external magnetic field.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • SPI FaultcriticalCall your installer
    Manual (PDF)

    Internal communication fails.

    Likely cause
    Could be caused by a strong external magnetic field.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • External Fan FaultwarningCall your installer
    Manual (PDF)

    External fan anomaly.

    Likely cause
    Fan blocked by foreign matters.
    What to do
    Stop inverter and check fan functionality.
  • Internal Fan FaultwarningCall your installer
    Manual (PDF)

    Internal fan anomaly.

    Likely cause
    Fan malfunction or failure.
    What to do
    Restart inverter, if fault recurs contact Sunways.
  • Inverter Over TemperaturewarningCall your installer
    Manual (PDF)

    Temperature anomaly inside the inverter.

    Likely cause
    Inverter is directly exposed to sunlight.
    What to do
    Reduce ambient temperature around inverter.
  • ISO Over LimitationwarningCall your installer
    Manual (PDF)

    Low system insulation resistance.

    Likely cause
    Check whether the PV panels and cables are broken or leaking.
    What to do
    Inspect PV system for leaks.
  • Mains LostwarningCall your installer
    Manual (PDF)

    Grid power outage, AC switch or circuit is disconnected.

    Likely cause
    Check whether the mains supply is lost. Check whether the AC breaker and terminals are well connected.
    What to do
    Verify AC supply and connections.
  • No Displaywarning
    Manual (PDF)

    No Display

    Likely cause
    Check whether cables are all firmly connected and DC switch is on. Check whether the input voltage meets the working voltage.
    What to do
    Check cables and mains supply.
  • PV Over VoltagewarningCall your installer
    Manual (PDF)

    PV over voltage is too high.

    Likely cause
    Input voltage is too high.
    What to do
    Reduce number of PV panels connected.

More Ningbo Sunways Technologies Co Ltd inverters

STT-5KTL-P (AS4777-2 2020)

5 kW · 3φ

STH-8KTL-HT-P (AS4777-2 2020)

8 kW · 3φ

STH-10KTL-HT-P (AS4777-2 2020)

10 kW · 3φ

STH-12KTL-HT-P (AS4777-2 2020)

12 kW · 3φ

STT-15KTL-P (AS4777-2 2020)

15 kW · 3φ

STT-17KTL-P (AS4777-2 2020)

17 kW · 3φ

View all Ningbo Sunways Technologies Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?