Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Ningbo Sunways Technologies
  4. STH-12KTL-HT-P

Hybrid inverter · Ningbo Sunways Technologies · CEC approved July 2026

Ningbo Sunways Technologies STH-12KTL-HT-P

CEC listing: STH-12KTL-HT-P (AS4777-2 2020)

A 12 kW three-phase hybrid inverter that is battery-ready.

Rated power
12kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

STH-12KTL-HT-P: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
12kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Ningbo Sunways Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Ningbo Sunways Technologies STH-12KTL-HT-P, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.6%
European efficiency97%
Physical
IP ratingIP66
Installation requirements
Top clearance0 mm
Side clearance0 mm
AC breaker20 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalNo

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
23 July 2026
Approval expiry
23 July 2029
Status
Active
Listed for STCs
Yes

About Ningbo Sunways Technologies

Years on the CEC list
4 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
51.0 kWh
Annual yield
18,615 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The Ningbo Sunways Technologies STH-12KTL-HT-P against the closest-power inverters from other brands.

Specification
Ningbo Sunways Technologies STH-12KTL-HT-PNingbo Sunways Technologies
Energizer Force 12.0HT+Energizer
Afore AF12K-THAfore
Rated power?12 kW12 kW12 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Ningbo Sunways Technologies STH-12KTL-HT-P

This warranty covers defects in the solar inverter for up to 10 years. Warranty void if not installed by an accredited installer. Claims can be made through the provided support details.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, or tampering.
Environment limits
None specified.
Read the official warranty document (PDF)

Fault & error codes — Ningbo Sunways Technologies STH-12KTL-HT-P

From the install manual

16 documented

Showing 16 of 16. The official install manual is the authoritative source — always confirm before acting.

  • AC Transducer FaultwarningCall your installer
    Manual (PDF)

    Fault with AC transducer detected.

    Likely cause
    AC measurement issues.
    What to do
    Restart the inverter. If the problem persists, contact installer or manufacturer for support.
  • Bus Voltage FaultwarningCall your installer
    Manual (PDF)

    Bus voltage exceeds allowed levels.

    Likely cause
    Input voltage over limitation.
    What to do
    Check if the input voltage is exceeding the limitation. Seek help from the installer or manufacturer if necessary.
  • DCI FaultwarningCall your installer
    Manual (PDF)

    DC injection fault detected.

    Likely cause
    Inverter malfunction or issue in the DC connection.
    What to do
    Restart the inverter. If the issue persists, contact your installer or manufacturer.
  • E2 FaultwarningCall your installer
    Manual (PDF)

    Error code E2 indicating a fault.

    Likely cause
    Hardware failure or communication issue.
    What to do
    Restart the inverter. For further assistance, contact your installer or manufacturer.
  • Flash FaultwarningCall your installer
    Manual (PDF)

    Software flash corruption fault.

    Likely cause
    Corrupted firmware.
    What to do
    Restart the inverter. If the problem continues, reach out to your installer or manufacturer.
  • GFCI Device FaultwarningCall your installer
    Manual (PDF)

    Fault detected in GFCI device.

    Likely cause
    Ground fault or leakage current.
    What to do
    Restart the inverter. If the issue continues, seek help from the installer or manufacturer.
  • GFCI FaultwarningCall your installer
    Manual (PDF)

    Ground Fault Circuit Interrupter fault.

    Likely cause
    Ground fault or leakage current detected.
    What to do
    Restart the inverter. If the problem continues, seek help from the installer or manufacturer.
  • Grid Frequency Faultwarning
    Manual (PDF)

    Grid frequency is out of allowed range.

    Likely cause
    Incorrect AC cable or connection issues.
    What to do
    Check whether the AC cable is correct and well connected. Consider changing to a different country with wider protection range if allowed.
  • Grid Voltage Faultwarning
    Manual (PDF)

    Grid voltage is out of allowed range.

    Likely cause
    High impedance of the AC cable causing voltage increase.
    What to do
    Check if the impedance of the AC cable is too high. Consider using a thicker AC cable.
  • Inverter Over TemperaturewarningCall your installer
    Manual (PDF)

    Inverter is overheated.

    Likely cause
    High input voltage or poor ventilation.
    What to do
    Check the input voltage and ensure proper ventilation. Contact installer or manufacturer if necessary.
  • ISO Over LimitationwarningCall your installer
    Manual (PDF)

    Isolation measurement exceeds limits.

    Likely cause
    Inverter fault or incorrect wiring.
    What to do
    Restart the inverter. If the issue persists, contact your installer or manufacturer.
  • Mains Lostwarning
    Manual (PDF)

    Power supply is lost.

    Likely cause
    Check the mains supply connection or AC breaker status.
    What to do
    Check whether the mains supply is lost. Check whether the AC breaker and terminal are well connected.
  • PV Over Voltagewarning
    Manual (PDF)

    Voltage from PV input exceeds limits.

    Likely cause
    Too many PV panels connected in string.
    What to do
    Reduce the number of PV panels to keep open-circuit voltage lower than the maximum allowed input voltage.
  • Relay Check FailwarningCall your installer
    Manual (PDF)

    Relay status check failed.

    Likely cause
    Malfunction in the relay mechanism.
    What to do
    Restart the inverter. Consult with your installer or manufacturer if the issue does not resolve.
  • SCI FaultwarningCall your installer
    Manual (PDF)

    Serial Communication Interface fault.

    Likely cause
    Communication failure or malfunction.
    What to do
    Restart the inverter. If the issue persists, contact your installer or manufacturer.
  • SPI FaultwarningCall your installer
    Manual (PDF)

    Signal Processing Interface fault.

    Likely cause
    Hardware or firmware issues.
    What to do
    Restart the inverter. For persistent issues, seek assistance from installer or manufacturer.

More Ningbo Sunways Technologies Co Ltd inverters

STH-10KTL-HT-P (AS4777-2 2020)

10 kW · 3φ

STT-15KTL-P (AS4777-2 2020)

15 kW · 3φ

STH-8KTL-HT-P (AS4777-2 2020)

8 kW · 3φ

STT-17KTL-P (AS4777-2 2020)

17 kW · 3φ

STT-5KTL (AS4777-2 2020)

5 kW · 3φ

STT-5KTL-P (AS4777-2 2020)

5 kW · 3φ

View all Ningbo Sunways Technologies Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?