Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Star Charge
  4. SI803SENA00

Hybrid inverter · Star Charge · CEC approved August 2025

Star Charge SI803SENA00

CEC listing: SI803SENA00 (AS4777-2 2020)

An 8 kW single-phase hybrid inverter that is battery-ready.

Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SI803SENA00: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
1yr
How long Wanbang Digital Energy Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Star Charge SI803SENA00, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
12 Aug 2025
Approval expiry
12 Aug 2028
Status
Active
Listed for STCs
Yes

About Star Charge

Years on the CEC list
1 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
6
CEC-approved batteries
5
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

1 years on the CEC list

How it compares

The Star Charge SI803SENA00 against the closest-power inverters from other brands.

Specification
Star Charge SI803SENA00Star Charge
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty1 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualOpens in a new tab
  • Compliance certificatePDF, opens in a new tab

1-year inverter warranty

Star Charge SI803SENA00

This warranty covers defects in material or workmanship for one year if installed and maintained correctly. Exclusions include improper installation, modifications, and misuse. Claims must be submitted within 60 days of discovering a defect.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Warranty voids if the Product is improperly installed, modified after sale, used with non-specified replacement parts, or misused. Also voided if used for commercial purposes, not maintained per guidelines, or operated outside manufacturer’s water pressures or temperatures.
Environment limits
This limited warranty will not cover any Product used for outdoor installations unless a weather cover that complies with manufacturer requirements is utilized.
Read the official warranty document (PDF)

Fault & error codes — Star Charge SI803SENA00

From the install manual

22 documented

Showing 22 of 22. The official install manual is the authoritative source — always confirm before acting.

  • F-104criticalCall your installer
    Manual (PDF)

    Inverter grid-connected relay fault

    Likely cause
    N/A
    What to do
    Contact Customer service.
  • F-110criticalCall your installer
    Manual (PDF)

    Leakage current detection unit fault

    Likely cause
    Check for PV cable breakage or improper grounding.
    What to do
    Restart inverter.
  • F-111criticalCall your installer
    Manual (PDF)

    Leakage current fault

    Likely cause
    Check if PV strings are grounded properly.
    What to do
    Contact Customer service.
  • F-112criticalCall your installer
    Manual (PDF)

    DC insulation fault

    Likely cause
    Improper grounding or shorts.
    What to do
    Wait until inverter restores normal work.
  • F-113criticalCall your installer
    Manual (PDF)

    Leakage current detection consistency error (Major)

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-114criticalCall your installer
    Manual (PDF)

    Frequency detection consistency error (Major)

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-115criticalCall your installer
    Manual (PDF)

    Power grid voltage detection consistency error (Major)

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-123criticalCall your installer
    Manual (PDF)

    Secondary memory failure

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-124criticalCall your installer
    Manual (PDF)

    Clock failure

    Likely cause
    N/A
    What to do
    Contact Customer service.
  • F-125criticalCall your installer
    Manual (PDF)

    Internal communication failure

    Likely cause
    N/A
    What to do
    Contact Customer service.
  • F-129criticalCall your installer
    Manual (PDF)

    Main memory failure

    Likely cause
    N/A
    What to do
    Contact Customer service.
  • F-100warning
    Manual (PDF)

    Over temperature

    Likely cause
    Check heatsink for obstructions/ventilation.
    What to do
    Check the ambient temperature around the inverter.
  • F-101warningCall your installer
    Manual (PDF)

    High DC input voltage

    Likely cause
    Disconnect the DC switch, remove the DC connector, measure the voltage of the PV string.
    What to do
    Re-layout the PV module string if voltage exceeds specification.
  • F-103warningCall your installer
    Manual (PDF)

    Unconnected grid

    Likely cause
    Check the AC main switch and power supply.
    What to do
    Measure grid connection specifications and reconnect.
  • F-105warningCall your installer
    Manual (PDF)

    Grid frequency fault

    Likely cause
    Grid frequency abnormal.
    What to do
    Wait for grid frequency to return to normal or contact service.
  • F-106warningCall your installer
    Manual (PDF)

    Grid voltage fault

    Likely cause
    Inconsistent grid voltage.
    What to do
    Check grid layout and reconnect.
  • F-107warningCall your installer
    Manual (PDF)

    DC component over range

    Likely cause
    Exceeds DC input specifications.
    What to do
    Restart inverter.
  • F-108warningCall your installer
    Manual (PDF)

    Current sensor fault

    Likely cause
    N/A
    What to do
    Wait until inverter restores normal work.
  • F-109warningCall your installer
    Manual (PDF)

    Fail safe

    Likely cause
    Check cable connection of CT or meter.
    What to do
    Restart inverter.
  • F-116infoCall your installer
    Manual (PDF)

    Leakage current detection consistency error (Minor)

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-117infoCall your installer
    Manual (PDF)

    Frequency detection consistency error (Minor)

    Likely cause
    N/A
    What to do
    Restart inverter.
  • F-118infoCall your installer
    Manual (PDF)

    Power grid voltage detection consistency error (Minor)

    Likely cause
    N/A
    What to do
    Restart inverter.

More Wanbang Digital Energy Co Ltd inverters

AD20074EU1923 (AS4777-2 2020)

7.4 kW · 1φ

SI603SENA00 (AS4777-2 2020)

6 kW · 1φ

SI503SENA00 (AS4777-2 2020)

5 kW · 1φ

AD20110EU1993 (AS4777-2 2020)

11 kW · 3φ

SI105TENT05 (AS4777-2 2020)

100 kW · 3φ

View all Wanbang Digital Energy Co Ltd inverters

More from Star Charge

Other CEC-approved products from Star Charge available in Australia.

Star Charge Batteries

vBox-10

9.3 kWh · LFP

vBox-14

12.4 kWh · LFP

vBox-17

15.6 kWh · LFP

vBox-20

18.6 kWh · LFP

vBox-7

6.2 kWh · LFP

View all Star Charge batteries
View full Star Charge manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?