Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Tbb Power
  4. Apollo Matrix 5.0S

Solar inverter · Tbb Power · CEC approval expired

Tbb Power Apollo Matrix 5.0S

A 5 kW single-phase solar inverter.

Rated power
5kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Apollo Matrix 5.0S: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
95.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
3yr
How long TBB POWER CO LTD stands behind it

Full datasheet

Every figure on file for the Tbb Power Apollo Matrix 5.0S, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency95%
DC input & MPPT
MPPT trackers2
Physical
IP ratingIP21

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
6 June 2023
Approval expiry
6 June 2026
Status
Not listed
Listed for STCs
No (not listed)

About Tbb Power

Years on the CEC list
3 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Tbb Power Apollo Matrix 5.0S against the closest-power inverters from other brands.

Specification
Tbb Power Apollo Matrix 5.0STbb Power
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?95.0%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty3 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty terms and installation guidePDF, opens in a new tab

3-year inverter warranty

Tbb Power Apollo Matrix 5.0S

The Apollo Matrix solar hybrid inverter is covered under a 3-year warranty, where you can claim for defects or performance failures. The warranty excludes non-accredited installations and modifications. To make a claim, contact the customer support service with proof of purchase.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Warranty void if not installed by a qualified professional or if modifications are made to the inverter.
Environment limits
None stated
Read the official warranty document (PDF)

Fault & error codes — Tbb Power Apollo Matrix 5.0S

From the install manual

15 documented

Showing 15 of 15. The official install manual is the authoritative source — always confirm before acting.

  • 101critical
    Manual (PDF)

    DC bus is over voltage

    Likely cause
    Check the battery voltage.
    What to do
    Check the battery voltage.
  • 102critical
    Manual (PDF)

    DC bus is under voltage

    Likely cause
    Check the battery connection and voltage.
    What to do
    Check the battery connection and voltage.
  • 103critical
    Manual (PDF)

    Hardware protection to prevent DC bus over voltage

    Likely cause
    Check the battery voltage and charger output voltage
    What to do
    Check the battery voltage and charger output voltage.
  • 104criticalCall your installer
    Manual (PDF)

    Auxiliary power supply is abnormal

    Likely cause
    Restart the inverter. Contact the installer if the error still exists
    What to do
    Restart the inverter. Contact the installer if the error still exists.
  • 107criticalCall your installer
    Manual (PDF)

    Sampling is abnormal

    Likely cause
    Restart inverter. Contact the installer if the error still exists.
    What to do
    Restart inverter. Contact the installer if the error still exists.
  • 109critical
    Manual (PDF)

    Output short circuit

    Likely cause
    Check if there is short circuit at loads.
    What to do
    Check the loads for short circuit.
  • 112criticalCall your installer
    Manual (PDF)

    Battery is severely under voltage

    Likely cause
    Connect to a valid generator. Restart the inverter and charge the battery.
    What to do
    Connect to a generator and restart the inverter.
  • 114critical
    Manual (PDF)

    Instantaneous over current

    Likely cause
    Check if there is a short circuit at loads.
    What to do
    Inspect the load connections for shorts.
  • 115critical
    Manual (PDF)

    Emergency stop

    Likely cause
    Check the EPO Dry Input.
    What to do
    Consult safety protocols and check inputs.
  • 116criticalCall your installer
    Manual (PDF)

    Relay is abnormal

    Likely cause
    Restart the inverter. Contact the installer if the error still exists.
    What to do
    Restart the inverter. Contact the installer if still a problem.
  • 105warning
    Manual (PDF)

    Heat sink's temperature is too high

    Likely cause
    Check and ensure the inverter has good ventilation
    What to do
    Check and ensure the inverter has good ventilation.
  • 106warning
    Manual (PDF)

    Transformer's temperature is too high

    Likely cause
    Check whether the air vent of the inverter is clear and unobstructed; check whether the ambient temperature exceeds 40℃.
    What to do
    Check the airflow and temperature.
  • 110warning
    Manual (PDF)

    Output over load

    Likely cause
    Reduce the load.
    What to do
    Reduce the load on the inverter.
  • 111warning
    Manual (PDF)

    Cooling system is abnormal

    Likely cause
    Check if the fan is working properly.
    What to do
    Check fan operation and airflow.
  • 108infoCall your installer
    Manual (PDF)

    ROM is abnormal

    Likely cause
    N/A
    What to do
    Consider replacement if issues continue.

More TBB POWER CO LTD inverters

CK5.0S

5 kW · 1φ

CK4.0S

4 kW · 1φ

CK6.0S

6 kW · 1φ

Apollo Matrix 3.0S

3 kW · 1φ

CK8.0S

8 kW · 1φ

View all TBB POWER CO LTD inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?