Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Redback Technologies
  4. Smart Inverter series
  5. SI10000

Hybrid inverter · Redback Technologies · Smart Inverter series · CEC approval expired

Redback Technologies SI10000

CEC listing: SI10000 (AS4777-2 2020)

A 10 kW single-phase hybrid inverter that is battery-ready.

Rated power
10kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SI10000: the short answer

In the Smart Inverter seriesThe 4th of 4 sizes, from 5 to 10 kW
10kWThe 4th of 4 sizes, from 5 to 10 kW
Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

Other sizes in the Smart Inverter series

  • 5 kW
  • 6 kW
  • 8 kW
  • 10 kW (this one)

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
10kW
How much solar it can turn into usable power at once
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit

Full datasheet

Every figure on file for the Redback Technologies SI10000, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.3%
European efficiency96.5%
DC input & MPPT
MPPT trackers2
Physical
Weight8.5 kg
IP ratingIP65
Operating temperature25°C to 60°C
Installation requirements
Top clearance50 mm
Side clearance40 mm
AC breaker40 A
Cable gauge16 mm²
Earthing methodGround connection required for all grids
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
8 June 2022
Approval expiry
27 July 2025
Status
Not listed
Listed for STCs
No (not listed)

About Redback Technologies

Years on the CEC list
5 years
Australian office
Yes
Category
Budget
CEC-approved inverters
34
CEC-approved batteries
14
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
42.5 kWh
Annual yield
15,513 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

redbacktech.com
5 years on the CEC list

How it compares

The Redback Technologies SI10000 against the closest-power inverters from other brands.

Specification
Redback Technologies SI10000Redback Technologies
Energizer Force 10.0HS+Energizer
Energizer Force 10.0HT+Energizer
Rated power?10 kW10 kW10 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
WarrantyNot on fileNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab

Warranty summary

Exeltech warrants its inverters for one year against defects. Coverage is voided by improper installation. To claim, complete the warranty registration card.

1-year inverter warranty

Redback Technologies SI10000

Exeltech warrants its inverters for one year against defects. Coverage is voided by improper installation. To claim, complete the warranty registration card.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Improper installation, misuse, alteration, unauthorized repair, or modification voids the warranty.
Read the official warranty document (PDF)

Fault & error codes — Redback Technologies SI10000

From the install manual

9 documented

Showing 9 of 9. The official install manual is the authoritative source — always confirm before acting.

  • 11, 16, 19-25criticalCall your installer
    Manual (PDF)

    System Fault

    Likely cause
    General system fault; requires diagnostic.
    What to do
    Disconnect AC and DC switches, and restart system after 15 minutes.
  • 106warningCall your installer
    Manual (PDF)

    Grounding Cable Fault

    Likely cause
    Improper grounding connection.
    What to do
    Check AC cable connections, the insulation between ground and live wire.
  • 12warningCall your installer
    Manual (PDF)

    Excess Leakage Current

    Likely cause
    Poor sunlight or damp environment.
    What to do
    Check AC and DC cables for proper insulation.
  • 2, 3, 14, 15warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    The grid voltage is higher than the set value.
    What to do
    Measure the actual grid voltage; modify overvoltage protection values with consent.
  • 39warningCall your installer
    Manual (PDF)

    Low System Insulation Resistance

    Likely cause
    High insulation resistance value beyond local regulations.
    What to do
    Check resistance of the string and DC cable; inspect for shorts.
  • 4, 5warningCall your installer
    Manual (PDF)

    Grid Undervoltage

    Likely cause
    The grid voltage is lower than the set value.
    What to do
    Measure the actual grid voltage; check AC cable connections.
  • 8warningCall your installer
    Manual (PDF)

    Grid Overfrequency

    Likely cause
    The grid frequency is beyond the set range.
    What to do
    Measure actual grid frequency; check protection parameters.
  • 88warningCall your installer
    Manual (PDF)

    Electric Arc Fault

    Likely cause
    A fault detected in electric connection.
    What to do
    Resolve fault via App or LCD; reconnect DC power supply.
  • 9, 10warningCall your installer
    Manual (PDF)

    Grid Underfrequency / Power Outage

    Likely cause
    The grid is not supplying power reliably.
    What to do
    Check if the AC cable is firmly in place.

More Redback Technologies inverters

SI10000 (AS4777-2 2020)

10 kW · 1φ

ST10000 (AS4777-2 2020)

10 kW · 1φ

RED-H3-S10HV (AS4777-2 2020)

9.999 kW · 1φ

RED-H4-S10HV (AS4777-2 2020)

9.999 kW · 1φ

RED-H3-S08HV (AS4777-2 2020)

8 kW · 1φ

RED-H4-S08HV (AS4777-2 2020)

8 kW · 1φ

View all Redback Technologies inverters

More from Redback Technologies

Other CEC-approved products from Redback Technologies available in Australia.

Redback Technologies Batteries

RED-P1-BE14HV

13.3 kWh · LFP

RED-P1-BE21HV

19.95 kWh · LFP

RED-P1-BE28HV

26.6 kWh · LFP

RED-P1-BE35HV

33.25 kWh · LFP

RED-P2-BE18HV

17.1 kWh · LFP

RED-P2-BE27HV

25.65 kWh · LFP

View all Redback Technologies batteries
View full Redback Technologies manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.