Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Redback Technologies
  4. RED-H3-S10HV

Hybrid inverter · Redback Technologies · CEC approved February 2026

Redback Technologies RED-H3-S10HV

CEC listing: RED-H3-S10HV (AS4777-2 2020)

A 10 kW single-phase hybrid inverter that is battery-ready.

Rated power
10kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

RED-H3-S10HV: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
10kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Redback Energy Pty Ltd stands behind it

Full datasheet

Every figure on file for the Redback Technologies RED-H3-S10HV, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.6%
Physical
IP ratingIP65
Installation requirements
Top clearance30 mm
Side clearance10 mm
AC breaker25 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
26 Feb 2026
Approval expiry
26 Feb 2029
Status
Active
Listed for STCs
Yes

About Redback Technologies

Years on the CEC list
5 years
Australian office
Yes
Category
Budget
CEC-approved inverters
34
CEC-approved batteries
14
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
42.5 kWh
Annual yield
15,511 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

redbacktech.com
5 years on the CEC list

How it compares

The Redback Technologies RED-H3-S10HV against the closest-power inverters from other brands.

Specification
Redback Technologies RED-H3-S10HVRedback Technologies
Solplanet ASW010K-SHSolplanet
Solplanet ASW10000-S-ASolplanet
Rated power?9.999 kW9.999 kW9.999 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Redback Technologies RED-H3-S10HV

This warranty covers defects and malfunctions for 10 years. It excludes damage from unauthorized installations. For claims, contact support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Void if installed by non-accredited personnel, any modification or tampering.
Environment limits
Not suitable for installations in full-sun locations or where wind-driven rain may penetrate the enclosure.
Read the official warranty document (PDF)

Fault & error codes — Redback Technologies RED-H3-S10HV

From the install manual

32 documented

Showing 32 of 32. The official install manual is the authoritative source — always confirm before acting.

  • E09criticalCall your installer
    Manual (PDF)

    No Grid

    Likely cause
    1. AC breaker is OFF 2. AC plug disconnected 3. Internal fuses are broken
    What to do
    1. Switch on AC breaker 2. Check the connection in AC plug and make sure it connects to inverter 3. Replace fuses and check all switching devices in boost & inverter stages
  • E30criticalCall your installer
    Manual (PDF)

    PV Voltage Over

    Likely cause
    1. Actual Solar voltage is over 510Vdc (H2.5) or 560Vdc (H3/H3A/H4A/H5A) 2. Detection circuit malfunction
    What to do
    1. Modify the solar array configuration and make the Voc less than 500Vdc (H2.5) or 550Vdc (H3/H3A/H4A/H5A) 2. Check the detection circuit inside the inverter
  • E34criticalCall your installer
    Manual (PDF)

    Insulation Fault

    Likely cause
    1. PV array insulation fault 2. Large PV array capacitance between Plus to Ground or Minus to Ground or both 3. Detection circuit malfunction
    What to do
    1. Check the insulation of Solar inputs 2. Check the capacitance, dry PV panel if necessary 3. Check the detection circuit inside the inverter
  • F01criticalCall your installer
    Manual (PDF)

    DC Injection

    Likely cause
    1. Utility waveform is abnormal 2. Detection circuit malfunction
    What to do
    1. Check the utility waveform. Grid connection of inverter needs to be far away from non-linear load if necessary 2. Check the detection circuit inside the inverter
  • F05criticalCall your installer
    Manual (PDF)

    NTC OTP

    Likely cause
    1. The ambient temp. is over 60°C 2. Detection circuit malfunction
    What to do
    1. Check the installation ambient temperature and environment 2. Check the detection circuit inside the inverter
  • F06criticalCall your installer
    Manual (PDF)

    NTC 0 Circuit Fail

    Likely cause
    1. Ambient temp. >100°C or 2. Detection circuit malfunction
    What to do
    1. Check the installation ambient temperature and environment 2. Check the detection circuit inside the inverter
  • F07criticalCall your installer
    Manual (PDF)

    NTC LTP

    Likely cause
    1. Ambient temp. < -40°C or 2. Detection circuit malfunction
    What to do
    1. Check the installation ambient temperature and environment 2. Check the detection circuit inside the inverter
  • F09criticalCall your installer
    Manual (PDF)

    Ntc 2 Circuit Fail

    Likely cause
    1. Ambient temp. >100°C or 2. Detection circuit malfunction
    What to do
    1. Check the installation ambient temperature and environment 2. Check the detection circuit inside the inverter
  • F15criticalCall your installer
    Manual (PDF)

    HW ADC1

    Likely cause
    1. Auxiliary power circuitry malfunction 2. Detection circuit malfunction
    What to do
    1. Check the auxiliary circuitry inside the inverter 2. Check the detection circuit inside the inverter
  • F16criticalCall your installer
    Manual (PDF)

    HW ADC2

    Likely cause
    1. Auxiliary power circuitry malfunction 2. Detection circuit malfunction
    What to do
    1. Check the auxiliary circuitry inside the inverter 2. Check the detection circuit inside the inverter
  • F17criticalCall your installer
    Manual (PDF)

    HW ADC3

    Likely cause
    1. Auxiliary power circuitry malfunction 2. Detection circuit malfunction
    What to do
    1. Check the auxiliary circuitry inside the inverter 2. Check the detection circuit inside the inverter
  • F19criticalCall your installer
    Manual (PDF)

    HW ADC5

    Likely cause
    1. Auxiliary power circuitry malfunction 2. Detection circuit malfunction
    What to do
    1. Check the auxiliary circuitry inside the inverter 2. Check the detection circuit inside the inverter
  • F20criticalCall your installer
    Manual (PDF)

    Efficiency Abnormal

    Likely cause
    1. The calibration is incorrect 2. Current feedback circuit is defective
    What to do
    1. Check the accuracy of current and power 2. Check the current feedback circuit inside the inverter
  • F23criticalCall your installer
    Manual (PDF)

    Communication Fault (Disconnected)

    Likely cause
    1. DSP is idling 2. The communication connection is disconnected 3. The communication circuit malfunction
    What to do
    1. Check reset and crystal in DSP 2. Check the connection between DSP and COMM 3. Check the communication circuit
  • F24criticalCall your installer
    Manual (PDF)

    RCMU Over Rating

    Likely cause
    1. PV array insulation fault 2. Large PV array capacitance between Plus to Ground or Minus to Ground 3. Either side of boost driver or boost choke malfunction 4. Detection circuit malfunction
    What to do
    1. Check the insulation of Solar inputs 2. Check the capacitance (+ GND & - GND), must an external transformer if necessary 3. Check boost driver & boost choke 4. Check the detection circuit inside the inverter
  • F27criticalCall your installer
    Manual (PDF)

    RCMU Circuit Fail

    Likely cause
    1. RCMU is disconnected 2. Detection circuit malfunction
    What to do
    1. Check the RCMU connection inside the inverter 2. Check the detection circuit inside the inverter
  • F28criticalCall your installer
    Manual (PDF)

    Relay Test Short

    Likely cause
    1. One or more relays are sticking 2. The driver circuit for the relay malfunction
    What to do
    1. Replace the defective relay(s) 2. Check the driver circuit inside the inverter
  • F29criticalCall your installer
    Manual (PDF)

    Relay Test Open

    Likely cause
    1. One or more relays are abnormal 2. The driver circuit for the relay malfunction 3. The detection accuracy is not correct for Vgrid and Vout
    What to do
    1. Replace the defective relay(s) 2. Check the driver circuit inside the inverter 3. Check the Vgrid and Vout voltage detection accuracy
  • F35criticalCall your installer
    Manual (PDF)

    HW Bus OVR

    Likely cause
    1. Driver for boost is defective 2. Voc of PV array is over 510Vdc (H2.5) or 560Vdc (H3/H3A/H4A/H5A) 3. Surge occurs during operation 4. Detection circuit malfunction
    What to do
    1. Check the driver circuit for boost inside the inverter 2. Modify the solar array setting, and make the Voc less than 500Vdc (H2.5) or 550Vdc (H3/H3A/H4A/H5A) 3. N/A 4. Check the detection circuit inside the inverter
  • F37criticalCall your installer
    Manual (PDF)

    OOCP

    Likely cause
    Detection circuit malfunction
    What to do
    Check the detection circuit inside the inverter
  • F42criticalCall your installer
    Manual (PDF)

    CT Sensor Fail (A)

    Likely cause
    1. Inverter choke Fail 2. Output Filter Fail 3. Detection circuit malfunction
    What to do
    1. Check Inverter choke inductance 2. Check output filter capacitance 3. Check the detection circuit inside the inverter
  • F60criticalCall your installer
    Manual (PDF)

    IOCP (PV1)

    Likely cause
    1. Switching device in boost is defective 2. Driver for boost is defective 3. Input current detection circuit malfunction
    What to do
    1. Check all switching device in boost 2. Check the driver circuit for boost inside the inverter 3. Check input current detection circuit
  • F61criticalCall your installer
    Manual (PDF)

    IOCP (PV2)

    Likely cause
    1. Switching device in boost is defective 2. Driver for boost is defective 3. Input current detection circuit malfunction
    What to do
    1. Check all switching device in boost 2. Check the driver circuit for boost inside the inverter 3. Check input current detection circuit
  • E01warningCall your installer
    Manual (PDF)

    Over Frequency

    Likely cause
    1. Actual utility frequency is higher than the OFR setting 2. Incorrect country setting 3. Detection circuit malfunction
    What to do
    1. Check the utility frequency on the inverter terminal 2. Check country setting 3. Check the detection circuit inside the inverter
  • E02warningCall your installer
    Manual (PDF)

    Under Frequency

    Likely cause
    1. Actual utility frequency is lower than the UFR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Check the utility frequency on the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • E10warningCall your installer
    Manual (PDF)

    Utility Voltage High

    Likely cause
    1. Actual utility voltage is higher than the UVR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Measure the utility AC voltage to the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • E11warningCall your installer
    Manual (PDF)

    Utility Voltage Low

    Likely cause
    1. Actual utility voltage is lower than the OVR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Measure the utility AC voltage to the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • E13warningCall your installer
    Manual (PDF)

    Slow OVR

    Likely cause
    1. Actual utility voltage is over than the OVR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Check the utility voltage on the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • E26warningCall your installer
    Manual (PDF)

    Slow OFR

    Likely cause
    1. Actual utility frequency is over the OFR setting 2. Incorrect country or grid setting 3. Detection circuit malfunction
    What to do
    1. Check the utility frequency on the inverter terminal 2. Check country setting 3. Check the detection circuit inside the inverter
  • E27warningCall your installer
    Manual (PDF)

    Slow UFR

    Likely cause
    1. Actual utility frequency is under the UFR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Check the utility frequency on the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • E28warningCall your installer
    Manual (PDF)

    Slow UVR

    Likely cause
    1. Actual utility voltage is under the UVR setting 2. Incorrect country or Grid setting 3. Detection circuit malfunction
    What to do
    1. Check the utility voltage on the inverter terminal 2. Check country & Grid setting 3. Check the detection circuit inside the inverter
  • F56warningCall your installer
    Manual (PDF)

    HW Incompatibility

    Likely cause
    HW power rating incorrect
    What to do
    Check comm. HW power rating info.

More Redback Energy Pty Ltd inverters

RED-H4-S10HV (AS4777-2 2020)

9.999 kW · 1φ

SI10000 (AS4777-2 2020)

10 kW · 1φ

SI10000 (AS4777-2 2020)

10 kW · 1φ

ST10000 (AS4777-2 2020)

10 kW · 1φ

RED-H3-S08HV (AS4777-2 2020)

8 kW · 1φ

RED-H4-S08HV (AS4777-2 2020)

8 kW · 1φ

View all Redback Energy Pty Ltd inverters

More from Redback Technologies

Other CEC-approved products from Redback Technologies available in Australia.

Redback Technologies Batteries

RED-P1-BE14HV

13.3 kWh · LFP

RED-P1-BE21HV

19.95 kWh · LFP

RED-P1-BE28HV

26.6 kWh · LFP

RED-P1-BE35HV

33.25 kWh · LFP

RED-P2-BE18HV

17.1 kWh · LFP

RED-P2-BE27HV

25.65 kWh · LFP

View all Redback Technologies batteries
View full Redback Technologies manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?