Hybrid inverter · Redback Technologies · CEC approved October 2026

Redback Technologies RED-H4-S06HV

CEC listing: RED-H4-S06HV (AS4777-2 2020)

A 6 kW single-phase hybrid inverter that is battery-ready.

Rated power
6kW
How much solar it can run at once
Battery-ready
Yes
A battery plugs straight in
Feed-in credits (DEBS)
No
DEBS pays for exports only when the inverter is 5 kW or less

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Redback Energy Pty Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
8 Oct 2026
Approval expiry
8 Oct 2029
Status
Active
Listed for STCs
Yes

About Redback Technologies

Years on the CEC list
5 years
Australian office
Yes
Category
Budget
CEC-approved inverters
34
CEC-approved batteries
14
View full profile →

Documents

WA compliance

Synergy's list
Not listed
Remote management
No record

This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.

Australian office

Has local presence

5 years on the CEC list

Perth performance

Estimate for a full-size array on this inverter

Daily yield
25.5 kWh
Annual yield
9,308 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

Full datasheet

Every figure on file for the Redback Technologies RED-H4-S06HV, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker32 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

How it compares

The Redback Technologies RED-H4-S06HV against the closest-power inverters from other brands.

Specification
Rated power?6 kW6 kW6 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

5-year inverter warranty

Redback Technologies RED-H4-S06HV

This warranty covers the inverter for 5 years, excluding damages from improper use. To claim, contact your installer with the invoice and serial number.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Failure to comply with operation instructions, faulty installation, misuse, damage during transport, insufficient ventilation, unauthorized interference, force majeure.

Fault & error codes — Redback Technologies RED-H4-S06HV

From the install manual

8 documented

Showing 8 of 8. The official install manual is the authoritative source — always confirm before acting.

  • 202criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value

    Likely cause
    PV voltage is too high
    What to do
    Disconnect the DC switch immediately and check the voltage of each PV string with a multimeter.
  • 203criticalCall your installer
    Manual (PDF)

    Insulation problem

    Likely cause
    Poor grounding or damaged insulation
    What to do
    Check if panels are grounded properly, inverter grounding, and impedance of PV lines. If issues persist, contact Growatt.
  • 407criticalCall your installer
    Manual (PDF)

    Auto test didn't pass

    Likely cause
    Initial tests have failed
    What to do
    Restart the inverter and repeat auto test. If the issue persists, contact Growatt.
  • 201warningCall your installer
    Manual (PDF)

    Leakage current too high

    Likely cause
    High leakage current detected in the system
    What to do
    Restart the inverter. If the error persists, contact Growatt.
  • 300warningCall your installer
    Manual (PDF)

    Utility grid voltage is out of permissible range

    Likely cause
    AC grid voltage fluctuation
    What to do
    Switch off the DC switch and check AC wiring and grid voltage.
  • 302warningCall your installer
    Manual (PDF)

    No AC connection

    Likely cause
    AC wiring issues
    What to do
    Check AC wiring and the status of AC breaker.
  • 303warningCall your installer
    Manual (PDF)

    Voltage of Neutral and PE above 30V

    Likely cause
    Improper grounding
    What to do
    Check voltage of Neutral and PE. If issues persist, contact the manufacturer.
  • 304warningCall your installer
    Manual (PDF)

    Utility grid frequency out of permissible range

    Likely cause
    AC grid frequency fluctuation
    What to do
    Switch off the DC switch and check AC wiring.

More Redback Technologies inverters

View all Redback Technologies inverters

More from Redback Technologies

Other CEC-approved products from Redback Technologies available in Australia.

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.