Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Ningbo Sunways Technologies
  4. STS-3KTL-P

Solar inverter · Ningbo Sunways Technologies · CEC approved September 2025

Ningbo Sunways Technologies STS-3KTL-P

CEC listing: STS-3KTL-P (AS4777-2 2020)

A 3 kW single-phase solar inverter.

Rated power
3kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

STS-3KTL-P: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3kW
How much solar it can turn into usable power at once
Max efficiency
98.1%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
5yr
How long Ningbo Sunways Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Ningbo Sunways Technologies STS-3KTL-P, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.1%
European efficiency97.5%
Physical
IP ratingIP65
Installation requirements
AC breaker20 A
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
29 Sept 2025
Approval expiry
22 June 2027
Status
Active
Listed for STCs
Yes

About Ningbo Sunways Technologies

Years on the CEC list
4 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
12.8 kWh
Annual yield
4,654 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The Ningbo Sunways Technologies STS-3KTL-P against the closest-power inverters from other brands.

Specification
Ningbo Sunways Technologies STS-3KTL-PNingbo Sunways Technologies
Energizer FORCE 3.0HSEnergizer
Energizer Force 3SEnergizer
Rated power?3 kW3 kW3 kW
Max efficiency?98.1%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty terms and installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Ningbo Sunways Technologies STS-3KTL-P

The warranty covers the inverter against defects in materials and workmanship, provided it's installed per instructions. Claims must be submitted via the service contact, but the warranty does not cover damage from improper installation or environment that does not meet specified requirements.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Damages caused by irregular transportation, incorrect storage, installation, or use; installation and use by non-professionals or untrained personnel; failure to comply with instructions and safety warnings; operation beyond specified parameters; unauthorized disassembly or modification; damages due to insufficient grounding.
Environment limits
Damages caused by abnormal natural environment (force majeure, such as lightning, earthquake, fire, storm, etc.)
Read the official warranty document (PDF)

Fault & error codes — Ningbo Sunways Technologies STS-3KTL-P

From the install manual

16 documented

Showing 16 of 16. The official install manual is the authoritative source — always confirm before acting.

  • Bus Voltage FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage is out of acceptable range.

    Likely cause
    Input voltage may be above limits.
    What to do
    Check input voltage and seek assistance if needed.
  • Grid Frequency FaultcriticalCall your installer
    Manual (PDF)

    Grid frequency is out of expected range.

    Likely cause
    Improper AC cable connections or grid frequency issues.
    What to do
    Check the AC cable connection and possibly change to another country with a wider protection range if allowed by local electricity providers.
  • Grid Voltage FaultcriticalCall your installer
    Manual (PDF)

    Grid voltage exceeded tolerable limits.

    Likely cause
    AC cable impedance might be too high, or voltage protection range needs adjustment.
    What to do
    Check the impedance of the AC cable and change to a thicker cable if necessary. Extend voltage protection range if allowed by the electricity company.
  • ISO Over LimitationcriticalCall your installer
    Manual (PDF)

    Insulation resistance is exceeding limits.

    Likely cause
    Potential failure in insulation system.
    What to do
    Restart the inverter and seek assistance.
  • PV Over VoltagecriticalCall your installer
    Manual (PDF)

    PV input voltage exceeded maximum levels.

    Likely cause
    Too many PV panels connected causing high voltage.
    What to do
    Reduce the number of PV panels to ensure the open-circuit voltage is below the maximum allowed.
  • AC Transducer Faultwarning
    Manual (PDF)

    Fault detected in AC transducer.

    Likely cause
    Monitoring issue with the AC side.
    What to do
    Restart the inverter and check connections.
  • DCI Faultwarning
    Manual (PDF)

    Direct current input fault detected.

    Likely cause
    Inverter issue requiring a restart.
    What to do
    Restart the inverter.
  • E2 FaultwarningCall your installer
    Manual (PDF)

    An unspecified internal error.

    Likely cause
    Possible internal fault.
    What to do
    Restart the inverter and seek help if issue persists.
  • Flash FaultwarningCall your installer
    Manual (PDF)

    Software failure observed in flash memory.

    Likely cause
    Internal software issue.
    What to do
    Restart the inverter and consult with the manufacturer if it continues.
  • GFCI Device FaultwarningCall your installer
    Manual (PDF)

    GFCI device is malfunctioning.

    Likely cause
    Issues with the GFCI device.
    What to do
    Restart the inverter and consult with an installer.
  • GFCI FaultwarningCall your installer
    Manual (PDF)

    Ground Fault Circuit Interrupter has tripped.

    Likely cause
    An electrical fault detected by the GFCI.
    What to do
    Restart inverter and check the system.
  • Inverter Over TemperaturewarningCall your installer
    Manual (PDF)

    Inverter's internal temperature exceeded safe limits.

    Likely cause
    Excessive input voltage or inadequate cooling.
    What to do
    Check for high input voltage and cool down the inverter; seek assistance if necessary.
  • Mains Lostwarning
    Manual (PDF)

    Power supply has been interrupted.

    Likely cause
    Check if the mains supply is lost.
    What to do
    Check whether the mains supply is lost and whether the AC breaker and terminal are well connected.
  • Relay Check FailwarningCall your installer
    Manual (PDF)

    Relay system failure.

    Likely cause
    Fault within relay connections.
    What to do
    Restart the inverter and consult assistance if necessary.
  • SCI Faultwarning
    Manual (PDF)

    Signal communication issue.

    Likely cause
    Faulty signal connections or internal errors.
    What to do
    Restart the inverter.
  • SPI Faultwarning
    Manual (PDF)

    Serial peripheral interface error.

    Likely cause
    Internal communication failure.
    What to do
    Restart the inverter and check connections.

More Ningbo Sunways Technologies Co Ltd inverters

STH-3KTL-HS (AS4777-2 2020)

3 kW · 1φ

STH-3KTL-HSS (AS4777-2 2020)

3 kW · 1φ

STH-3.6KTL-HS (AS4777-2 2020)

3.6 kW · 1φ

STH-3.6KTL-HSS (AS4777-2 2020)

3.6 kW · 1φ

STS-3.6KTL-P (AS4777-2 2020)

3.6 kW · 1φ

STH-4.2KTL-HS (AS4777-2 2020)

4.2 kW · 1φ

View all Ningbo Sunways Technologies Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?