Hybrid inverter · Ningbo Sunways Technologies · CEC approval expired
CEC listing: STH-3KTL-HS (AS4777-2 2020)
A 3 kW single-phase hybrid inverter that is battery-ready.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Ningbo Sunways Technologies STH-3KTL-HS, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 97.6% |
| European efficiency | 97% |
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| Top clearance | 100 mm |
| Side clearance | 50 mm |
| AC breaker | 20 A |
| Cable gauge | 6 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | Yes |
| Estimated install time | 5 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Ningbo Sunways Technologies STH-3KTL-HS against the closest-power inverters from other brands.
| Specification | Ningbo Sunways Technologies STH-3KTL-HSNingbo Sunways Technologies | Energizer FORCE 3.0HSEnergizer | Energizer Force 3SEnergizer |
|---|---|---|---|
| Rated power? | 3 kW | 3 kW | 3 kW |
| Max efficiency? | 97.6% | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Hybrid | Hybrid | Solar |
| Battery ready | Yes | Yes | No |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers defects in materials and workmanship for 10 years. It excludes damage from improper installation. To claim, contact customer support.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 28 of 28. The official install manual is the authoritative source — always confirm before acting.
Flash FaultcriticalCall your installerFirmware related fault
Hard FaultcriticalCall your installerCritical system fault
Inverter OCcriticalCall your installerInverter Over Current
Inverter OFcriticalCall your installerInverter Over Frequency
Inverter OVcriticalCall your installerInverter Over Voltage
Mains LostcriticalCall your installerMain power supply is lost
PV Over VoltagecriticalCall your installerInput voltage from PV panels too high
AC Transducer FaultwarningCall your installerAC current measurement fault
Backup OPwarningBackup operation issue
Backup OVwarningCall your installerBackup voltage is too high
Bat OVwarningBattery Over Voltage
Battery FaultwarningCall your installerBattery related issue
Bus Volt LowwarningCall your installerLow bus voltage detected
Bus Voltage FaultwarningCall your installerBus voltage exceeds limits
DCI FaultwarningCall your installerDC Input Fault
E2 FaultwarningCall your installerGeneral Fault Code E2
GFCI Device FaultwarningCall your installerGround Fault Device Fault
GFCI FaultwarningCall your installerGround fault circuit interrupter fault
Grid Frequency FaultwarningCall your installerGrid frequency is out of allowable limits
Grid Voltage FaultwarningCall your installerGrid voltage is out of acceptable limits
Inverter Over TemperaturewarningCall your installerInverter overheating
ISO Over LimitationwarningCall your installerInsulation fault detected
Meter Comm FaultwarningMeter communication fault
Phase Order ErrwarningPhase order is incorrect
PV Power LowwarningInsufficient power from PV array
Relay Check FailwarningCall your installerRelay functionality error
SCI FaultwarningCall your installerSerial Communication Interface Fault
SPI FaultwarningCall your installerSPI Communication Fault
STH-3KTL-HSS (AS4777-2 2020)
3 kW · 1φ
STS-3KTL-P (AS4777-2 2020)
3 kW · 1φ
STH-3.6KTL-HS (AS4777-2 2020)
3.6 kW · 1φ
STH-3.6KTL-HSS (AS4777-2 2020)
3.6 kW · 1φ
STS-3.6KTL-P (AS4777-2 2020)
3.6 kW · 1φ
STH-4.2KTL-HS (AS4777-2 2020)
4.2 kW · 1φ
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.