Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Ningbo Sunways Technologies
  4. STH-3KTL-HSS

Hybrid inverter · Ningbo Sunways Technologies · CEC approval expired

Ningbo Sunways Technologies STH-3KTL-HSS

CEC listing: STH-3KTL-HSS (AS4777-2 2020)

A 3 kW single-phase hybrid inverter that is battery-ready.

Rated power
3kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

STH-3KTL-HSS: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Ningbo Sunways Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Ningbo Sunways Technologies STH-3KTL-HSS, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.6%
European efficiency97%
Physical
IP ratingIP65
Installation requirements
Top clearance100 mm
Side clearance50 mm
AC breaker20 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
10 Nov 2023
Approval expiry
10 Nov 2026
Status
Not listed
Listed for STCs
No (not listed)

About Ningbo Sunways Technologies

Years on the CEC list
4 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
12.8 kWh
Annual yield
4,654 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The Ningbo Sunways Technologies STH-3KTL-HSS against the closest-power inverters from other brands.

Specification
Ningbo Sunways Technologies STH-3KTL-HSSNingbo Sunways Technologies
Energizer FORCE 3.0HSEnergizer
Energizer Force 3SEnergizer
Rated power?3 kW3 kW3 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

10-year inverter warranty

Ningbo Sunways Technologies STH-3KTL-HSS

This warranty covers defects in materials and workmanship for 10 years. It excludes damage from improper installation. To claim, contact customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, or tampering voids the warranty.
Environment limits
None specified.
Read the official warranty document (PDF)

Fault & error codes — Ningbo Sunways Technologies STH-3KTL-HSS

From the install manual

28 documented

Showing 28 of 28. The official install manual is the authoritative source — always confirm before acting.

  • Flash FaultcriticalCall your installer
    Manual (PDF)

    Firmware related fault

    Likely cause
    Corrupted firmware or internal error.
    What to do
    Restart the inverter; if issue persists, consult installer.
  • Hard FaultcriticalCall your installer
    Manual (PDF)

    Critical system fault

    Likely cause
    Indicates serious issue, possibly hardware-related.
    What to do
    Restart the inverter; seek immediate assistance from installer.
  • Inverter OCcriticalCall your installer
    Manual (PDF)

    Inverter Over Current

    Likely cause
    Current draw exceeds maximum limits; wiring fault.
    What to do
    Restart inverter; check system wiring; contact installer.
  • Inverter OFcriticalCall your installer
    Manual (PDF)

    Inverter Over Frequency

    Likely cause
    Faulty frequency detection or grid issue.
    What to do
    Restart the inverter; seek installer support if necessary.
  • Inverter OVcriticalCall your installer
    Manual (PDF)

    Inverter Over Voltage

    Likely cause
    Voltage level exceeds inverter's capacity.
    What to do
    Restart inverter; consult installer if issue continues.
  • Mains LostcriticalCall your installer
    Manual (PDF)

    Main power supply is lost

    Likely cause
    Check if the mains supply is interrupted or if there’s an issue with the AC breaker and connections.
    What to do
    Check the mains supply and connections.
  • PV Over VoltagecriticalCall your installer
    Manual (PDF)

    Input voltage from PV panels too high

    Likely cause
    Too many panels in series resulting in high open-circuit voltage.
    What to do
    Reduce the number of PV panels in series.
  • AC Transducer FaultwarningCall your installer
    Manual (PDF)

    AC current measurement fault

    Likely cause
    Malfunctioning measurement device.
    What to do
    Restart the inverter.
  • Backup OPwarning
    Manual (PDF)

    Backup operation issue

    Likely cause
    Excessive loads on the backup system.
    What to do
    Reduce loads connected in backup; restart inverter.
  • Backup OVwarningCall your installer
    Manual (PDF)

    Backup voltage is too high

    Likely cause
    Potential wiring fault in the backup circuit.
    What to do
    Restart the inverter; check wiring in backup system.
  • Bat OVwarning
    Manual (PDF)

    Battery Over Voltage

    Likely cause
    Battery voltage exceeds the allowable limit.
    What to do
    Check battery connections; ensure maximum voltage is not exceeded.
  • Battery FaultwarningCall your installer
    Manual (PDF)

    Battery related issue

    Likely cause
    Can indicate a fault within the battery system.
    What to do
    Restart inverter; contact installer for battery checks.
  • Bus Volt LowwarningCall your installer
    Manual (PDF)

    Low bus voltage detected

    Likely cause
    Possible internal fault.
    What to do
    Restart the inverter; contact installer if the issue persists.
  • Bus Voltage FaultwarningCall your installer
    Manual (PDF)

    Bus voltage exceeds limits

    Likely cause
    Check if input voltage is over limitations.
    What to do
    Check input voltage levels.
  • DCI FaultwarningCall your installer
    Manual (PDF)

    DC Input Fault

    Likely cause
    Inverter malfunction or reset needed.
    What to do
    Restart the inverter.
  • E2 FaultwarningCall your installer
    Manual (PDF)

    General Fault Code E2

    Likely cause
    Inverter malfunction.
    What to do
    Restart the inverter.
  • GFCI Device FaultwarningCall your installer
    Manual (PDF)

    Ground Fault Device Fault

    Likely cause
    Inverter malfunction or wiring issue.
    What to do
    Restart the inverter.
  • GFCI FaultwarningCall your installer
    Manual (PDF)

    Ground fault circuit interrupter fault

    Likely cause
    Fault in ground connection or inverter malfunction.
    What to do
    Restart the inverter.
  • Grid Frequency FaultwarningCall your installer
    Manual (PDF)

    Grid frequency is out of allowable limits

    Likely cause
    Incorrect AC cables or setup.
    What to do
    Verify AC cable connections.
  • Grid Voltage FaultwarningCall your installer
    Manual (PDF)

    Grid voltage is out of acceptable limits

    Likely cause
    High impedance in the AC cable or incorrect voltage protection settings.
    What to do
    Check AC cable connections and possibly change cable size or settings.
  • Inverter Over TemperaturewarningCall your installer
    Manual (PDF)

    Inverter overheating

    Likely cause
    High input voltage or insufficient cooling.
    What to do
    Check input voltage and ensure proper cooling.
  • ISO Over LimitationwarningCall your installer
    Manual (PDF)

    Insulation fault detected

    Likely cause
    Insulation resistance is below acceptable levels.
    What to do
    Restart the inverter.
  • Meter Comm Faultwarning
    Manual (PDF)

    Meter communication fault

    Likely cause
    Issues with meter or meter wiring.
    What to do
    Verify meter connections; check meter for faults.
  • Phase Order Errwarning
    Manual (PDF)

    Phase order is incorrect

    Likely cause
    Improper phase sequence in inverter setup.
    What to do
    Restart the inverter; verify phase connections.
  • PV Power Lowwarning
    Manual (PDF)

    Insufficient power from PV array

    Likely cause
    PV array may be partially shaded or insufficient sunlight.
    What to do
    Check PV array for obstructions; verify sunlight availability.
  • Relay Check FailwarningCall your installer
    Manual (PDF)

    Relay functionality error

    Likely cause
    Inverter malfunction.
    What to do
    Restart the inverter.
  • SCI FaultwarningCall your installer
    Manual (PDF)

    Serial Communication Interface Fault

    Likely cause
    Inverter malfunction or wiring issue.
    What to do
    Restart the inverter.
  • SPI FaultwarningCall your installer
    Manual (PDF)

    SPI Communication Fault

    Likely cause
    Inverter malfunction or wiring issue.
    What to do
    Restart the inverter.

More Ningbo Sunways Technologies Co Ltd inverters

STH-3KTL-HS (AS4777-2 2020)

3 kW · 1φ

STS-3KTL-P (AS4777-2 2020)

3 kW · 1φ

STH-3.6KTL-HS (AS4777-2 2020)

3.6 kW · 1φ

STH-3.6KTL-HSS (AS4777-2 2020)

3.6 kW · 1φ

STS-3.6KTL-P (AS4777-2 2020)

3.6 kW · 1φ

STH-4.2KTL-HS (AS4777-2 2020)

4.2 kW · 1φ

View all Ningbo Sunways Technologies Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?