Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Hiconics Eco-energy Drive Technology
  4. MH-HYIV29.9-TH-AU

Hybrid inverter · Hiconics Eco-energy Drive Technology · CEC approved September 2026

Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AU

CEC listing: MH-HYIV29.9-TH-AU (AS4777-2 2020)

A 29.9 kW three-phase hybrid inverter that is battery-ready.

Rated power
29.9kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MH-HYIV29.9-TH-AU: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
29.9kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Hiconics Eco-energy Drive Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AU, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP65
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker50 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
16 Sept 2026
Approval expiry
16 Sept 2029
Status
Active
Listed for STCs
Yes

About Hiconics Eco-energy Drive Technology

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

3 years on the CEC list

How it compares

The Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AU against the closest-power inverters from other brands.

Specification
Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AUHiconics Eco-energy Drive Technology
Solplanet ASW29.9K-THSolplanet
Solplanet ASW30K-LT-G3Solplanet
Rated power?29.9 kW29.9 kW29.9 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AU

HYXiPOWER warrants that products are covered for up to 25 years depending on the model. Major exclusions include improper installation and unauthorized repairs. Claims must be reported within 14 days.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, unauthorized repairs, damage due to negligence or improper use, using products for demonstration purposes.
Environment limits
Operating temperature must be between -10~50°C; warranty void if exceeded.
Read the official warranty document (PDF)

Fault & error codes — Hiconics Eco-energy Drive Technology MH-HYIV29.9-TH-AU

From the install manual

20 documented

Showing 20 of 20. The official install manual is the authoritative source — always confirm before acting.

  • IE016criticalCall your installer
    Manual (PDF)

    EPS Overload Fault

    Likely cause
    EPS overload fault.
    What to do
    Shutdown high-power device and press the 'ESC' key to restart the inverter. Or ask the installer for help.
  • IE017criticalCall your installer
    Manual (PDF)

    OverLoad Fault

    Likely cause
    On-grid mode overload
    What to do
    Shutdown high-power device and press the 'ESC' key to restart the inverter. Or ask the installer for help.
  • IE001warningCall your installer
    Manual (PDF)

    TZ Protect Fault

    Likely cause
    Overcurrent fault.
    What to do
    Wait for a while to check if you're back to normal. Disconnect PV+ PV- and batteries, reconnect.
  • IE002warningCall your installer
    Manual (PDF)

    Grid Lost Fault

    Likely cause
    Grid input voltage out of normal range.
    What to do
    Check grid input voltage if it's within normal. Or ask the installer for help.
  • IE003warningCall your installer
    Manual (PDF)

    Grid Volt Fault

    Likely cause
    Power grid voltage overrun.
    What to do
    Wait a moment, if the utility returns to normal, the system will reconnect. Please check if the grid voltage is within normal range. Or ask the installer for help.
  • IE004warningCall your installer
    Manual (PDF)

    Grid Freq Fault

    Likely cause
    Electricity frequency beyond range.
    What to do
    If the utility returns to normal, the system will reconnect. Or ask the installer for help.
  • IE005warningCall your installer
    Manual (PDF)

    PV Volt Fault

    Likely cause
    PV voltage out of range.
    What to do
    Check the output voltage of the PV panel. Or ask the installer for help.
  • IE006warningCall your installer
    Manual (PDF)

    Bus Volt Fault

    Likely cause
    Bus voltage fault.
    What to do
    Press the 'ESC' key to restart the inverter. Check that the PV input open circuit voltage is in the normal range. Or ask the installer for help.
  • IE007warningCall your installer
    Manual (PDF)

    Bat Volt Fault

    Likely cause
    Battery voltage fault.
    What to do
    Check battery input voltage if it's within normal range. Or ask the installer for help.
  • IE008warningCall your installer
    Manual (PDF)

    AC10M Volt Fault

    Likely cause
    Grid voltage out of range in the last 10 minutes.
    What to do
    The system will return to normal if the grid returns to normal. Or ask the installer for help.
  • IE009warningCall your installer
    Manual (PDF)

    DCI OCP Fault

    Likely cause
    DCI overcurrent protection fault.
    What to do
    Wait for a while to check if it's back to normal. Or ask the installer for help.
  • IE010warningCall your installer
    Manual (PDF)

    DCV OVP Fault

    Likely cause
    DCV EPS overvoltage protection failure.
    What to do
    Wait for a while to check if it's back to normal. Or ask the installer for help.
  • IE011warningCall your installer
    Manual (PDF)

    SW OCP Fault

    Likely cause
    Software Detection of Overcurrent Fault.
    What to do
    Wait for a while to check if it's back to normal. Shut down photovoltaic, battery, and grid connections. Or ask the installer for help.
  • IE012warningCall your installer
    Manual (PDF)

    RC OCP Fault

    Likely cause
    Overcurrent protection fault.
    What to do
    Check the impedance of DC input and AC output. Wait for a while to check if it's back to normal. Or ask the installer for help.
  • IE013warningCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    Insulation Fault.
    What to do
    Please check the wire insulation for damage. Wait for a while to check if it’s back to normal. Or ask the installer for help.
  • IE014warningCall your installer
    Manual (PDF)

    Temp Over Fault

    Likely cause
    Temperature beyond limit.
    What to do
    Check if ambient temperature exceeds the limit. Or ask the installer for help.
  • IE015warningCall your installer
    Manual (PDF)

    Bat Power Low

    Likely cause
    Battery power is low.
    What to do
    Close the high-power device and press the 'ESC' key to restart the inverter. Please charge the battery to a level higher than the protection capacity or protection voltage.
  • IE018warningCall your installer
    Manual (PDF)

    BMS Lost

    Likely cause
    Battery communication loss.
    What to do
    Check that the communication lines between the battery and the inverter are properly connected. Or ask the installer for help.
  • IE019warningCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    Fan Fault.
    What to do
    Check for any foreign matter that may have caused the fan not to function properly. Or ask the installer for help.
  • IE020warningCall your installer
    Manual (PDF)

    Low Temp

    Likely cause
    Low temperature fault.
    What to do
    Check if the ambient temperature is too low. Or ask the installer for help.

More Hiconics Eco-energy Drive Technology Co Ltd inverters

MEI2-HT29.9H-AU (AS4777-2 2020)

29.9 kW · 3φ

MEI2-HT30H-AU (AS4777-2 2020)

30 kW · 3φ

MH-HYIV30.0-TH-AU (AS4777-2 2020)

30 kW · 3φ

MEI2-HT25H-AU (AS4777-2 2020)

25 kW · 3φ

MH-HYIV25.0-TH-AU (AS4777-2 2020)

25 kW · 3φ

MEI2-HT20H-AU (AS4777-2 2020)

20 kW · 3φ

View all Hiconics Eco-energy Drive Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?