Hybrid inverter · FoxESS · CEC approved May 2025
CEC listing: 1K5-1P-HI-8 (AS4777-2 2020)
An 8 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the FoxESS 1K5-1P-HI-8, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 97.8% |
| Physical | |
| IP rating | IP65 |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| AC breaker | 25 A |
| Cable gauge | 4 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
au.fox-ess.comThe FoxESS 1K5-1P-HI-8 against the closest-power inverters from other brands.
| Specification | FoxESS 1K5-1P-HI-8FoxESS | Energizer Force 8.0HS+Energizer | Energizer Force 8.0HT+Energizer |
|---|---|---|---|
| Rated power? | 8 kW | 8 kW | 8 kW |
| Max efficiency? | 97.8% | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
Fox ESS offers a 10-year warranty covering defects in materials and workmanship for its inverters and charge controllers. It excludes coverage for non-accredited installations and modifications; claims must be made by authorized installers.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 70 of 70. The official install manual is the authoritative source — always confirm before acting.
ARM EEPROM FaultcriticalCall your installerThe manager eeprom is fault.
Bat Boost FaultcriticalCall your installerThe battery boost circuit mosfet is fail.
Bat Buck FaultcriticalCall your installerThe battery buck circuit mosfet is fail.
Bat Relay OpencriticalCall your installerThe battery relay keeps open.
Bat Relay Short CircuitcriticalCall your installerThe battery relay keeps close.
Bat Volt FaultcriticalCall your installerBattery voltage fault.
BatCon Dir FaultcriticalCall your installerThe battery connection is reversed.
Bms ChgCur HighcriticalCall your installerBattery charge over current.
Bms DchgCur HighcriticalCall your installerBattery discharge over current.
Bms HW ProtectcriticalCall your installerBattery hardware under protection.
Bms Insul FaultcriticalCall your installerBattery insulation fault.
Bms M&S UnmatchcriticalCall your installerThe software between Master and Slave are not match.
Bms Mfg UnmatchcriticalCall your installerThe cell manufacture is different.
Bms Relay FaultcriticalCall your installerBattery relay fault.
Bms SwHw UnmatchcriticalCall your installerThe slave software and hardware are not match.
Bms Temp HighcriticalCall your installerBattery over temperature.
Bms Type UnmatchcriticalCall your installerThe capacity of battery packs is different.
Bms Volt HighcriticalCall your installerBattery over voltage.
Bms Volt LowcriticalCall your installerBattery under voltage.
BmsCircuit FaultcriticalCall your installerBms hardware circuit fault.
BmsCurSen FaultcriticalCall your installerBattery current sensor fault.
BmsTempSen FaultcriticalCall your installerBattery temperature sensor fault.
BmsVoltsSen FaultcriticalCall your installerBattery voltage sensor fault.
Dci Cons FaultcriticalCall your installerThe dci sample value between master and slave is not consistent.
DCI FaultcriticalCall your installerDC component is out of limit in output current.
Eps Over LoadcriticalCall your installerOver load in off grid mode.
Eps Relay FaultcriticalCall your installerThe eps relay is failed.
Grid Lost FaultcriticalCall your installerGrid is lost.
GridF Cons FaultcriticalCall your installerThe grid frequency sample value between master and slave is not consistent.
GridV Cons FaultcriticalCall your installerThe grid voltage sample value between master and slave is not consistent.
Ground FaultcriticalCall your installerThe ground connection is failed.
HW Bus Vol FaultcriticalCall your installerBus voltage out of range detected by hardware.
Inv EEPROM FaultcriticalCall your installerThe inverter eeprom is fault.
Iso FaultcriticalCall your installerThe isolation is failed.
M1 Close FaultcriticalCall your installerThe grid relay M1 keep close.
M2 Close FaultcriticalCall your installerThe grid relay M2 keep close.
Main Relay OpencriticalCall your installerThe grid relay keeps open.
MDSP Smpl FaultcriticalCall your installerThe master sample detection circuit is failed.
Over Load FaultcriticalCall your installerOver load in on grid mode.
PvCon Dir FaultcriticalCall your installerThe PV connection is reversed.
Rc Cons FaultcriticalCall your installerThe residual current sample value between master and slave is not consistent.
RDSP Smpl FaultcriticalCall your installerThe slave sample detection circuit is failed.
Res Cur FaultcriticalCall your installerThe residual current is high.
Res Cur HW FaultcriticalCall your installerResidual current detection device is failed.
S1 Close FaultcriticalCall your installerThe grid relay S1 keep close.
S2 Close FaultcriticalCall your installerThe grid relay S2 keep close.
SW Bus Vol FaultcriticalCall your installerBus voltage out of range detected by software.
10min Volt FaultwarningCall your installerThe grid voltage is out of range for the last 10 minutes.
Bms ChgReq NoAckwarningCall your installerNo action for charging request.
Bms Ext FaultwarningCall your installerThe communication between BMS and Inverter is interrupted.
Bms Int FaultwarningCall your installerDIP switch at the wrong position; The communication between battery packs is interrupted.
BMS LostwarningCall your installerThe communication between BMS and Inverter is interrupted.
Bms Temp LowwarningCall your installerBattery under temperature.
Bms Ver UnmatchwarningCall your installerThe software between slaves are different.
BmsCellImbalancewarningCall your installerThe capacities of cells are different.
Grid Freq FaultwarningCall your installerGrid frequency out of range.
Grid Volt FaultwarningCall your installerGrid voltage out of range.
HW Bat Cur FaultwarningCall your installerBattery current high detected by hardware.
HW Inv Cur FaultwarningCall your installerOutput current high detected by hardware.
HW Pv Cur FaultwarningCall your installerPV input current high detected by hardware.
MDSP SPI FaultwarningCall your installerThe communication between master and slave is fail.
Meter Lost FaultwarningCall your installerThe communication between meter and Inverter is interrupted.
Pv Volt FaultwarningCall your installerPV voltage out of range.
RDSP SPI FaultwarningCall your installerThe communication between master and slave is fail.
SCI FaultwarningCall your installerThe communication between master and manager is fail.
SW Bat Cur FaultwarningCall your installerBattery current high detected by software.
SW Inv Cur FaultwarningCall your installerOutput current high detected by software.
SW Pv Cur FaultwarningCall your installerPV input current high detected by software.
Temp FaultwarningCall your installerThe inverter temperature is high.
Bat Power LowinfoThe battery power is low.
G8 (AS4777-2 2020)
8 kW · 1φ
G8 (AS4777-2 2020)
8 kW · 1φ
KA8 (AS4777-2 2020)
8 kW · 1φ
KH8 (AS4777-2 2020)
8 kW · 1φ
PQ1-8.0_EQ5500-S_2S (AS4777-2 2020)
8 kW · 1φ
PQ1-8.0_EQ5500-S_3S (AS4777-2 2020)
8 kW · 1φ
Other CEC-approved products from FoxESS available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.