Hybrid inverter · Neovolt · CEC approved November 2026

Neovolt BW-INV-SPH3.6K

CEC listing: BW-INV-SPH3.6K (AS4777-2 2020)

A 3.6 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
Yes
Rated power
3.6kW
How much solar it can run at once
Battery-ready
Yes
A battery plugs straight in
Feed-in credits (DEBS)
Yes
DEBS pays for exports only when the inverter is 5 kW or less

Listed for battery storage on Synergy's list: Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.6kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Bytewatt Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
18 Nov 2026
Approval expiry
17 Mar 2028
Status
Active
Listed for STCs
Yes

About Neovolt

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
21
CEC-approved batteries
14
View full profile →

Documents

WA compliance

Listed for battery storage on Synergy's list
Yes
Remote management
On Synergy's list

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. On Synergy's list dated 6 November 2026, this model is approved for remote management (CSIP-AUS).

3 years on the CEC list

Perth performance

Estimate for a full-size array on this inverter

Daily yield
15.3 kWh
Annual yield
5,585 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

Full datasheet

Every figure on file for the Neovolt BW-INV-SPH3.6K, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker50 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

How it compares

The Neovolt BW-INV-SPH3.6K against the closest-power inverters from other brands.

Specification
Rated power?3.6 kW3.6 kW3.6 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridSolarHybrid
Battery readyYesNoYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

10-year inverter warranty

Neovolt BW-INV-SPH3.6K

This warranty covers inverter performance for 10 years. Capacity retention must be above 80%, and claims can be made by contacting support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, or tampering.
Environment limits
Operating Temperature Range: -20~60°C, voids if exceeded.

Fault & error codes — Neovolt BW-INV-SPH3.6K

From the install manual

45 documented

Showing 45 of 45. The official install manual is the authoritative source — always confirm before acting.

  • 100005criticalCall your installer
    Manual (PDF)

    Bus over voltage protection

    Likely cause
    Check whether the input voltage of PV1 and PV2 exceeds 580V. Restart the inverter to see if the fault persists, if not call the service center.
    What to do
    Inspect PV input voltage and restart the inverter.
  • 100007criticalCall your installer
    Manual (PDF)

    Insulation fault

    Likely cause
    Check whether the PV cable connection is reliable. Check whether the PV cable is damaged.
    What to do
    Inspect the integrity of the PV cables.
  • 100011criticalCall your installer
    Manual (PDF)

    Over temperature

    Likely cause
    Check the environment around the inverter for poor heat dissipation.
    What to do
    Ensure proper ventilation around the inverter.
  • 100017criticalCall your installer
    Manual (PDF)

    MPPT1 over voltage protection

    Likely cause
    Check the PV1 voltage, if it exceeds 585V reduce the number of PV panels.
    What to do
    Inspect and adjust PV setup.
  • 100018criticalCall your installer
    Manual (PDF)

    MPPT1 switch over current protection

    Likely cause
    Try to reduce the PV power. Restart the inverter to check if the fault persists.
    What to do
    Lower the PV power and restart the inverter.
  • 100019criticalCall your installer
    Manual (PDF)

    MPPT1 hardware over current protection

    Likely cause
    Try to reduce the PV power. Restart the inverter to check if the fault persists.
    What to do
    Lower the PV power and restart the inverter.
  • 100020criticalCall your installer
    Manual (PDF)

    MPPT1 over temperature protection

    Likely cause
    Try to lower the ambient temperature around the inverter.
    What to do
    Ensure the inverter is properly ventilated and cool.
  • 100021criticalCall your installer
    Manual (PDF)

    MPPT2 over voltage protection

    Likely cause
    Check the PV2 voltage. If it exceeds 585V reduce the number of PV modules.
    What to do
    Inspect and adjust PV setup.
  • 100022criticalCall your installer
    Manual (PDF)

    MPPT2 switch over current protection

    Likely cause
    Try to reduce the PV power. Restart the inverter to check if the fault persists.
    What to do
    Lower the PV power and restart the inverter.
  • 100023criticalCall your installer
    Manual (PDF)

    MPPT2 hardware over current protection

    Likely cause
    Try to reduce the PV power. Restart the inverter to check if the fault persists.
    What to do
    Lower the PV power and restart the inverter.
  • 100024criticalCall your installer
    Manual (PDF)

    MPPT2 over temperature protection

    Likely cause
    Try to lower the ambient temperature around the inverter.
    What to do
    Ensure the inverter is properly ventilated and cool.
  • 100025criticalCall your installer
    Manual (PDF)

    Battery over voltage protection

    Likely cause
    Check if the battery voltage exceeds the charging cut-off by more than 20V.
    What to do
    Inspect battery voltage settings and connections.
  • 100026criticalCall your installer
    Manual (PDF)

    Battery under voltage protection

    Likely cause
    Check if the battery voltage is lower than the discharge cut-off.
    What to do
    Inspect battery voltage settings and connections.
  • 100027criticalCall your installer
    Manual (PDF)

    Battery loss

    Likely cause
    Confirm that wiring is normal and check if battery voltage sampling is less than 75V.
    What to do
    Inspect battery connections and voltage.
  • 100028criticalCall your installer
    Manual (PDF)

    Battery over temperature protection

    Likely cause
    Try to lower the ambient temperature around the inverter.
    What to do
    Ensure the inverter is properly ventilated and cool.
  • 100029criticalCall your installer
    Manual (PDF)

    Battery 1 charge over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100030criticalCall your installer
    Manual (PDF)

    Battery 1 discharge over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100031criticalCall your installer
    Manual (PDF)

    Battery 2 charge over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100032criticalCall your installer
    Manual (PDF)

    Battery 2 discharge over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100033criticalCall your installer
    Manual (PDF)

    Battery 1 hardware over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100034criticalCall your installer
    Manual (PDF)

    Battery 2 hardware over current protection

    Likely cause
    Try to reduce battery power in use.
    What to do
    Lower battery usage power and restart the inverter.
  • 100035criticalCall your installer
    Manual (PDF)

    Inverter over temperature protection

    Likely cause
    Try to lower the ambient temperature around the inverter.
    What to do
    Ensure proper ventilation and cooling for inverter.
  • 100036criticalCall your installer
    Manual (PDF)

    Grid max voltage protection

    Likely cause
    Check grid voltage and connections. Might indicate a grid issue.
    What to do
    Consult with utility service provider regarding grid conditions.
  • 100037criticalCall your installer
    Manual (PDF)

    Inverter under voltage protection

    Likely cause
    Check for short circuits or impact load on off-grid terminals.
    What to do
    Inspect connections and loads on the inverter.
  • 100038criticalCall your installer
    Manual (PDF)

    Output DC over current protection

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Inspect output connections and load.
  • 100039criticalCall your installer
    Manual (PDF)

    Inverter over current protection

    Likely cause
    Check for overloads or short circuits on inverter terminals.
    What to do
    Inspect load and connections, then restart.
  • 100040criticalCall your installer
    Manual (PDF)

    Inverter hardware over current protection

    Likely cause
    Check for overloads or short circuits on inverter terminals.
    What to do
    Inspect load and connections, then restart.
  • 100041criticalCall your installer
    Manual (PDF)

    Output DC over voltage protection

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Inspect configurations and connections for voltage spikes.
  • 100042criticalCall your installer
    Manual (PDF)

    Output short circuit

    Likely cause
    Check load connections; possibly a wiring issue.
    What to do
    Inspect connections and rectify faults.
  • 100043criticalCall your installer
    Manual (PDF)

    Output overload

    Likely cause
    Check if load exceeds the rated power of the inverter.
    What to do
    Reduce load and ensure proper settings on the inverter.
  • 100000warning
    Manual (PDF)

    Grid over voltage protection

    Likely cause
    Check whether the grid is abnormal. Confirm whether the grid cable connection is normal. Restart the inverter and check if the fault persists.
    What to do
    Check grid status and cable connections, then restart the inverter.
  • 100001warning
    Manual (PDF)

    Grid under voltage protection

    Likely cause
    Check whether the grid is abnormal. Confirm whether the grid cable connection is normal. Restart the inverter and check if the fault persists.
    What to do
    Check grid status and cable connections, then restart the inverter.
  • 100002warning
    Manual (PDF)

    Grid over frequency protection

    Likely cause
    Check whether the grid is abnormal. Confirm whether the grid cable connection is normal. Restart the inverter and check if the fault persists.
    What to do
    Check grid status and cable connections, then restart the inverter.
  • 100003warning
    Manual (PDF)

    Grid under frequency protection

    Likely cause
    Check whether the grid is abnormal. Confirm whether the grid cable connection is normal. Restart the inverter and check if the fault persists.
    What to do
    Check grid status and cable connections, then restart the inverter.
  • 100008warning
    Manual (PDF)

    GFCI fault

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Restart the inverter.
  • 100009warning
    Manual (PDF)

    Leakage current test failure

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Restart the inverter.
  • 100010warning
    Manual (PDF)

    Grid relay fault

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Restart the inverter.
  • 100014warning
    Manual (PDF)

    Communication fault

    Likely cause
    Restart the inverter and check if the fault persists.
    What to do
    Restart the inverter.
  • 110000warning
    Manual (PDF)

    Battery over voltage alarm

    Likely cause
    Check battery voltage against the cut-off point.
    What to do
    Inspect battery settings and voltage levels.
  • 110001warning
    Manual (PDF)

    Battery under voltage alarm

    Likely cause
    Check battery voltage against the cut-off point.
    What to do
    Inspect battery settings and voltage levels.
  • 110002warning
    Manual (PDF)

    Output overload alarm

    Likely cause
    Evaluate load against inverter capacity.
    What to do
    Reduce load on inverter and monitor.
  • 110003warning
    Manual (PDF)

    Abnormal temperature sensor alarm

    Likely cause
    Inspect temperature sensor connections and integrity.
    What to do
    Check sensor functionality.
  • 110004warning
    Manual (PDF)

    DC power alarm

    Likely cause
    Total power of battery and PV is less than load power.
    What to do
    Evaluate generated vs consumption power.
  • 110005warning
    Manual (PDF)

    Battery stops running alarm

    Likely cause
    Check battery connections and voltage.
    What to do
    Ensure battery is connected and functional.
  • 110006warning
    Manual (PDF)

    Over temperature alarm

    Likely cause
    Check ambient temperature around inverter.
    What to do
    Ensure voltage and thermal management on inverter is effective.

More Neovolt inverters

View all Neovolt inverters

More from Neovolt

Other CEC-approved products from Neovolt available in Australia.

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.