Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Neovolt
  4. BW-INV-SPB5K

Battery inverter · Neovolt · CEC approved May 2023

Neovolt BW-INV-SPB5K

CEC listing: BW-INV-SPB5K (AS4777-2 2020)

A 5 kW single-phase battery inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

BW-INV-SPB5K: the short answer

Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
97.3%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
10yr
How long Suzhou Bytewatt Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Neovolt BW-INV-SPB5K, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.3%
DC input & MPPT
MPPT trackers2
Physical
Dimensions (H×W×D)405 × 590 × 205 mm
Weight19.5 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance200 mm
Side clearance100 mm
AC breaker50 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
22 May 2023
Approval expiry
2 Jan 2027
Status
Active
Listed for STCs
Yes

About Neovolt

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
18
CEC-approved batteries
14
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Neovolt BW-INV-SPB5K against the closest-power inverters from other brands.

Specification
Neovolt BW-INV-SPB5KNeovolt
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?97.3%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeBatteryHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty terms and compliance certificatePDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab

10-year inverter warranty

Neovolt BW-INV-SPB5K

This warranty covers defects for 10 years. Key exclusions include unauthorized installations. To make a claim, contact support with proof of purchase.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Warranty void if not installed by accredited personnel, modified, or tampered with.
Environment limits
Operating temperature range of -20 to 60°C; any temperature exceeding this may void the warranty.
Read the official warranty document (PDF)

Fault & error codes — Neovolt BW-INV-SPB5K

From the install manual

17 documented

Showing 17 of 17. The official install manual is the authoritative source — always confirm before acting.

  • 100000criticalCall your installer
    Manual (PDF)

    Grid Overvoltage Protection

    Likely cause
    Grid voltage exceeding limits.
    What to do
    Check power grid and reconnect if safe.
  • 100001criticalCall your installer
    Manual (PDF)

    Grid Undervoltage Protection

    Likely cause
    Grid voltage too low.
    What to do
    Contact utility to investigate grid power.
  • 100005criticalCall your installer
    Manual (PDF)

    Bus Overvoltage Protection

    Likely cause
    Input voltage of PV arrays exceeds acceptable levels.
    What to do
    Reduce number of PV modules or consult service center.
  • 100007criticalCall your installer
    Manual (PDF)

    Insulation Fault

    Likely cause
    Potential damage or failure in PV cables.
    What to do
    Check PV connections and call service center.
  • 100009criticalCall your installer
    Manual (PDF)

    Leakage Current Test Failure

    Likely cause
    Failure in current leakage detection system.
    What to do
    Notify the installer to inspect the system.
  • 100017criticalCall your installer
    Manual (PDF)

    MPPT1 Overvoltage Protection

    Likely cause
    PV1 voltage exceeding limits.
    What to do
    Reduce number of PV modules on PV1.
  • 100018criticalCall your installer
    Manual (PDF)

    MPPT1 Short Circuit Protection

    Likely cause
    Short circuit condition in PV1.
    What to do
    Reduce PV power and check system connections.
  • 100021criticalCall your installer
    Manual (PDF)

    MPPT2 Overvoltage Protection

    Likely cause
    PV2 voltage exceeding limits.
    What to do
    Reduce number of PV modules on PV2.
  • 100022criticalCall your installer
    Manual (PDF)

    MPPT2 Short Circuit Protection

    Likely cause
    Short circuit condition in PV2.
    What to do
    Reduce PV power and check system connections.
  • 110000criticalCall your installer
    Manual (PDF)

    Battery Overvoltage Alarm

    Likely cause
    Actual battery voltage is too high.
    What to do
    Check battery connections and voltage levels.
  • 100002warningCall your installer
    Manual (PDF)

    Grid Overfrequency Protection

    Likely cause
    Grid frequency above acceptable limits.
    What to do
    Monitor grid frequency and report to utility if persistent.
  • 100003warningCall your installer
    Manual (PDF)

    Grid Underfrequency Protection

    Likely cause
    Grid frequency below acceptable limits.
    What to do
    Monitor grid frequency and report to utility if persistent.
  • 100008warningCall your installer
    Manual (PDF)

    GFCI Fault

    Likely cause
    Ground fault protection failure.
    What to do
    Restart inverter and check if fault persists.
  • 100011warningCall your installer
    Manual (PDF)

    Overtemperature

    Likely cause
    Poor heat dissipation around the inverter.
    What to do
    Ensure proper ventilation and check surroundings.
  • 100020warningCall your installer
    Manual (PDF)

    MPPT1 Over Temperature Protection

    Likely cause
    Excessive temperature at MPPT.
    What to do
    Check environment and improve cooling system.
  • 110001warningCall your installer
    Manual (PDF)

    Battery Undervoltage Alarm

    Likely cause
    Battery voltage is too low for operation.
    What to do
    Verify battery connections and charge the battery.
  • 110002warningCall your installer
    Manual (PDF)

    Output Overload Alarm

    Likely cause
    Load exceeds rated output power limit.
    What to do
    Disconnect excess load and restart inverter.

More Suzhou Bytewatt Technology Co Ltd inverters

BW-INV-SPH5K (AS4777-2 2020)

5 kW · 1φ

BW-INV-SPH6K (AS4777-2 2020)

6 kW · 1φ

BW-INV-SPH6K1 (AS4777-2 2020)

6 kW · 1φ

BW-INV-SPH3.6K (AS4777-2 2020)

3.68 kW · 1φ

BW-INV-SPB8K (AS4777-2 2020)

8 kW · 1φ

BW-INV-SPB8K1 (AS4777-2 2020)

8 kW · 1φ

View all Suzhou Bytewatt Technology Co Ltd inverters

More from Neovolt

Other CEC-approved products from Neovolt available in Australia.

Neovolt Batteries

BW-BAT-10.1P

9.6 kWh · LFP

BW-BAT-10.1P II

19.2 kWh

BW-BAT-10.1P III

28.8 kWh

BW-BAT-10.1P IV

38.4 kWh

BW-BAT-10.1P V

48 kWh

BW-BAT-10.1P VI

57.6 kWh

View all Neovolt batteries
View full Neovolt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?