Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE-M8-S-INV

Hybrid inverter · Alpha ESS · CEC approved July 2026

Alpha ESS SMILE-M8-S-INV

CEC listing: SMILE-M8-S-INV (AS4777-2 2020)

An 8 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-M8-S-INV: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Alpha ESS Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Alpha ESS SMILE-M8-S-INV, by section.

Full datasheet, by section
SpecificationValue
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker50 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
7 July 2026
Approval expiry
7 July 2029
Status
Active
Listed for STCs
Yes

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-M8-S-INV against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-M8-S-INVAlpha ESS
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualOpens in a new tab

10-year inverter warranty

Alpha ESS SMILE-M8-S-INV

This warranty covers 10 years and ensures at least 70% capacity at 10 years, but is void if not installed properly. Claims can be made through the online portal.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Void if installed by non-accredited installers, or if modified or tampered with.
Environment limits
The ambient temperature during operation must not fall below -10°C or exceed 50°C.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-M8-S-INV

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • 100005warningCall your installer
    Manual (PDF)

    Bus Over Voltage

    Likely cause
    The voltage of the PV input exceeds the set limits (580V).
    What to do
    Check and ensure that the PV input voltage does not exceed allowed limits. Restart the inverter after correcting the issue.
  • 100007warningCall your installer
    Manual (PDF)

    Insulation Fault

    Likely cause
    An insulation error in the PV cable.
    What to do
    Verify the reliability of the PV cable connections and check for any damage.
  • 100008warningCall your installer
    Manual (PDF)

    GFCI Fault

    Likely cause
    Fault in the ground fault circuit interrupter (GFCI).
    What to do
    Restart the inverter. If the issue persists, contact customer service.
  • 4warningCall your installer
    Manual (PDF)

    Inverter communication lost

    Likely cause
    The inverter is unable to communicate due to an issue with the connection or firmware.
    What to do
    Restart the system. If the problem persists, contact customer service for further assistance.
  • 5warningCall your installer
    Manual (PDF)

    Grid meter lost

    Likely cause
    The grid meter is disconnected or there is a configuration issue.
    What to do
    Verify system configuration and connections for the grid meter. If unresolved, contact customer service.
  • 6warningCall your installer
    Manual (PDF)

    PV meter lost

    Likely cause
    The PV meter is offline or has a connection problem.
    What to do
    Check the configuration and communication cables for the PV meter. Contact customer service if the issue continues.
  • 60002warningCall your installer
    Manual (PDF)

    Circuit Breaker Open

    Likely cause
    The circuit breaker for the battery is turned off.
    What to do
    Switch on the circuit breakers of all batteries. If the error continues, contact customer service.
  • 60004warningCall your installer
    Manual (PDF)

    Follower Battery Communication Lost

    Likely cause
    Loss of communication with the follower battery.
    What to do
    Contact customer service.
  • 60006warningCall your installer
    Manual (PDF)

    Host Battery Communication Lost

    Likely cause
    Loss of communication with the host battery.
    What to do
    Contact customer service for further assistance.
  • 60008warningCall your installer
    Manual (PDF)

    Multi Master Error

    Likely cause
    More than one master battery detected in the system.
    What to do
    Restart all batteries. If it persists, contact customer service.
  • 7warningCall your installer
    Manual (PDF)

    BMS communication lost

    Likely cause
    The communication between the battery management system and the inverter is disrupted.
    What to do
    Check the BMS communication connections and ensure the battery is powered on. Contact service if the problem remains.

More Alpha ESS Co Ltd inverters

SMILE-M9-S-INV (AS4777-2 2020)

9 kW · 1φ

SMILE-M10-S-INV (AS4777-2 2020)

9.999 kW · 1φ

SMILE-S6-HV-INV (AS4777-2 2020)

6 kW · 1φ

SMILE-B5 (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 II (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 III (AS4777-2 2020)

5 kW · 1φ

View all Alpha ESS Co Ltd inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?