Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE series
  5. SMILE-S6-HV-INV

Hybrid inverter · Alpha ESS · SMILE series · CEC approval expired

Alpha ESS SMILE-S6-HV-INV

CEC listing: SMILE-S6-HV-INV (AS4777-2 2020)

A 6 kW single-phase hybrid inverter that is battery-ready.

Rated power
6kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-S6-HV-INV: the short answer

In the SMILE seriesThe 2nd of 3 sizes, from 5 to 10 kW
6kWThe 2nd of 3 sizes, from 5 to 10 kW
Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

Other sizes in the SMILE series

  • 5 kW
  • 6 kW (this one)
  • 10 kW

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Alpha ESS SMILE-S6-HV-INV, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Physical
Dimensions (H×W×D)210 × 610 × 627 mm
Weight30 kg
Operating temperature-10°C to 50°C
Installation requirements
Cable gauge10 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
17 Feb 2022
Approval expiry
24 June 2025
Status
Not listed
Listed for STCs
No (not listed)

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
25.5 kWh
Annual yield
9,308 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-S6-HV-INV against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-S6-HV-INVAlpha ESS
Energizer FORCE 6.0HSEnergizer
Energizer Force 6.0HT+Energizer
Rated power?6 kW6 kW6 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
WarrantyNot on fileNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab

Warranty summary

The warranty covers defects in material and workmanship for 5 years, with a performance warranty of 10 years for specific battery models. Exclusions include damage from improper installation and environmental factors.

5-year inverter warranty

Alpha ESS SMILE-S6-HV-INV

The warranty covers defects in material and workmanship for 5 years, with a performance warranty of 10 years for specific battery models. Exclusions include damage from improper installation and environmental factors.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Void if installed incorrectly, modified outside of Alpha ESS instructions, used inappropriately, or if the product serial number is altered.
Environment limits
The operating temperature must not fall below -10 °C or exceed 50 °C.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-S6-HV-INV

From the install manual

21 documented

Showing 21 of 21. The official install manual is the authoritative source — always confirm before acting.

  • 100005warningCall your installer
    Manual (PDF)

    BUS_OVP1

    Likely cause
    If it happens occasionally, the inverter can recover automatically, no processing is required.
    What to do
    Monitor the inverter. If the problem persists, contact customer service.
  • 100007warningCall your installer
    Manual (PDF)

    Insulation_fault

    Likely cause
    Wet installation environment or rainy weather causing alarms.
    What to do
    Check the solar panels and cables. If the issue persists, inspect the strings for any abnormality or contact customer service.
  • 100008warningCall your installer
    Manual (PDF)

    GFCI_fault

    Likely cause
    Frequent occurrences may indicate inverter fault.
    What to do
    Check insulation resistance. If it persists, contact customer service.
  • 100010warningCall your installer
    Manual (PDF)

    Grid_relay_fault

    Likely cause
    Short-term power grid abnormalities.
    What to do
    If it occurs frequently, refer to guidance for grid voltage alarm troubleshooting.
  • 100012warning
    Manual (PDF)

    PV_Reverse

    Likely cause
    Incorrect PV string cable connections.
    What to do
    Reconnect the cables correctly.
  • 100025warningCall your installer
    Manual (PDF)

    BAT_OVP

    Likely cause
    Battery voltage outside allowable range during installation or operation.
    What to do
    Check wiring and BMS communication.
  • 100026warningCall your installer
    Manual (PDF)

    BAT_UVP

    Likely cause
    Battery voltage outside allowable range during installation or operation.
    What to do
    Inspect battery switches and BMS alarms.
  • 100027warning
    Manual (PDF)

    Battery_lose

    Likely cause
    Improper battery wiring or and open DC switch.
    What to do
    Check connection integrity.
  • 100030warning
    Manual (PDF)

    BAT1_discharge_OCP

    Likely cause
    Battery over-discharged.
    What to do
    Reduce backup load and restart the inverter.
  • 100038warningCall your installer
    Manual (PDF)

    Output_DC_over_current

    Likely cause
    Short-lived abnormality of power grid.
    What to do
    Monitor the inverter. If the problem persists, contact customer service.
  • 100041warningCall your installer
    Manual (PDF)

    Output_DC_over_voltage

    Likely cause
    Short-lived abnormality of power grid.
    What to do
    Monitor the inverter. If the problem continues, contact customer service.
  • 100042warning
    Manual (PDF)

    Output_short

    Likely cause
    Backup load is shorted.
    What to do
    Disconnect backup load and restart the inverter.
  • 100043warning
    Manual (PDF)

    Output_overload

    Likely cause
    Backup load is overloaded.
    What to do
    Reduce load or disconnect backup load, restart inverter.
  • 100046warningCall your installer
    Manual (PDF)

    DC_Input_Disturbance

    Likely cause
    Short-lived abnormality.
    What to do
    If persistent, contact customer service.
  • 100052warningCall your installer
    Manual (PDF)

    Backup_ovp

    Likely cause
    Short-lived abnormality of the inverter.
    What to do
    If persistent, contact customer service.
  • 100054warningCall your installer
    Manual (PDF)

    Dc_bus_undervolt

    Likely cause
    Short-lived abnormality.
    What to do
    If persistent, contact customer service.
  • 100060warningCall your installer
    Manual (PDF)

    Dsp_selfcheck

    Likely cause
    Internal procedure compatibility issues.
    What to do
    Contact customer service.
  • 100122warningCall your installer
    Manual (PDF)

    EEPROM_RW_Failure

    Likely cause
    Normal result of remote upgrade process.
    What to do
    If it persists, contact customer service.
  • 100123warningCall your installer
    Manual (PDF)

    DSP_communication_failure

    Likely cause
    Lost communication with DCDC module.
    What to do
    Restart inverter after powering off.
  • 110006warningCall your installer
    Manual (PDF)

    over_temperature_alarm

    Likely cause
    Installation site exposure or poor ventilation.
    What to do
    Check ambient conditions and contact customer service.
  • 110021warningCall your installer
    Manual (PDF)

    Grid Loss Alarm

    Likely cause
    Short-lived power grid abnormality.
    What to do
    Contact the local power operator for modifications.

More Alpha ESS inverters

SMILE-B5 (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 II (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 III (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 IV (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 V (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 VI (AS4777-2 2020)

5 kW · 1φ

View all Alpha ESS inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?