Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE-B5 III

Battery inverter · Alpha ESS · CEC approved March 2026

Alpha ESS SMILE-B5 III

CEC listing: SMILE-B5 III (AS4777-2 2020)

A 5 kW single-phase battery inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-B5 III: the short answer

Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
95.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
1
One string of panels, tuned as a whole
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
10yr
How long Alpha ESS Co Ltd stands behind it

Full datasheet

Every figure on file for the Alpha ESS SMILE-B5 III, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Maximum power5 kW
Apparent power8 kVA
Phases1
Efficiency
Max efficiency95%
European efficiency95%
CEC-weighted efficiency95%
DC input & MPPT
MPPT trackers1
Max input voltage0 V
MPPT voltage min0 V
MPPT voltage max0 V
Max input current0 A
Battery & backup
Battery compatibleNo
Backup capableNo
Continuous backup0 kW
Physical
Dimensions (H×W×D)210 × 610 × 627 mm
Weight27.7 kg
IP ratingIP65
CoolingN/A
Operating temperature-10°C to 50°C
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Cable gauge25 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
No
CEC approved
5 Mar 2026
Approval expiry
12 Oct 2027
Status
Active
Listed for STCs
Yes

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-B5 III against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-B5 IIIAlpha ESS
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?95.0%Not on fileNot on file
MPPT trackers?1Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeBatteryHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Alpha ESS SMILE-B5 III

This warranty covers the AlphaESS Residential Product Series for five years, ensuring replacement or repair for defects in materials or workmanship. It excludes issues arising from improper installation or environmental damage.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Invalid if products are installed by non-accredited installers, modified, or operated under improper conditions. Claims due to accidental damage, theft, vandalism, or exposure to inappropriate environmental conditions void the warranty.
Environment limits
The ambient temperature during the operation of the Products shall not fall below -10 °C or exceed 50 °C.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-B5 III

From the install manual

41 documented

Showing 41 of 41. The official install manual is the authoritative source — always confirm before acting.

  • 100007criticalCall your installer
    Manual (PDF)

    Insulation fault

    Likely cause
    Moisture or wet installation conditions affecting solar panels
    What to do
    Improve installation environment or disconnect connections for troubleshooting; contact customer service if issues persist.
  • 100008criticalCall your installer
    Manual (PDF)

    GFCI fault

    Likely cause
    Possible insulation fault or ground fault
    What to do
    Check insulation and ground connections; contact customer service if issues persist.
  • 100027criticalCall your installer
    Manual (PDF)

    Battery lose

    Likely cause
    Connection issue with battery wiring
    What to do
    Check battery wiring; ensure all connections are tight.
  • 100038criticalCall your installer
    Manual (PDF)

    Output DC Over Current

    Likely cause
    Short-term grid voltage issue or inverter fault.
    What to do
    Contact service for further assistance.
  • 100042criticalCall your installer
    Manual (PDF)

    Output Short Circuit

    Likely cause
    Shorted load on backup side.
    What to do
    Disconnect load; restart inverter if needed.
  • 100043criticalCall your installer
    Manual (PDF)

    Output Overload

    Likely cause
    Backup load exceeds inverter capacity.
    What to do
    Reduce load; check connections.
  • 100060criticalCall your installer
    Manual (PDF)

    DSP Self-Check Fail

    Likely cause
    Internal operation issue; likely requires service.
    What to do
    Contact customer service for repairs.
  • 100123criticalCall your installer
    Manual (PDF)

    DSP Communication Failure

    Likely cause
    Loss of communication in the module.
    What to do
    Power off for 10 mins; contact service if unresolved.
  • 110005criticalCall your installer
    Manual (PDF)

    Battery Stops Running Alarm

    Likely cause
    Battery operational issues.
    What to do
    Contact services immediately.
  • 110006criticalCall your installer
    Manual (PDF)

    Over Temperature Alarm

    Likely cause
    Poor ventilation or direct sunlight exposure.
    What to do
    Check installation conditions and contact service if necessary.
  • 110014criticalCall your installer
    Manual (PDF)

    PV Over Voltage

    Likely cause
    Faulty PV string configurations.
    What to do
    Check string configurations; adjust as necessary.
  • 110024criticalCall your installer
    Manual (PDF)

    10min Grid Voltage Alarm

    Likely cause
    Average grid voltage exceeds limits.
    What to do
    Check grid voltage settings; contact service for guidance.
  • 110027criticalCall your installer
    Manual (PDF)

    Line-Neutral Reverse Alarm

    Likely cause
    Improper wiring connections.
    What to do
    Check connections; correct as needed.
  • 110029criticalCall your installer
    Manual (PDF)

    GFCI Alarm

    Likely cause
    Possible inverter fault; check GFCI system.
    What to do
    Contact service for further assistance.
  • 110030criticalCall your installer
    Manual (PDF)

    Isolation Alarm

    Likely cause
    System requires a check for performance.
    What to do
    Monitor; contact service if unresolved.
  • 110034criticalCall your installer
    Manual (PDF)

    Fan Abnormal Alarm

    Likely cause
    Fan performance check needed.
    What to do
    Inspect or replace fans; contact service if unsure.
  • 100005warning
    Manual (PDF)

    BUS OVP1

    Likely cause
    Occasional overvoltage on bus
    What to do
    No action required if it resolves automatically; contact customer service if persistent.
  • 100010warning
    Manual (PDF)

    Grid relay fault

    Likely cause
    Short-term grid instability
    What to do
    No action required if resolves automatically; contact customer service for frequent occurrences.
  • 100025warningCall your installer
    Manual (PDF)

    Battery OVP

    Likely cause
    Excessive voltage in battery system
    What to do
    Check battery voltage; ensure wiring is secure.
  • 100026warningCall your installer
    Manual (PDF)

    Battery Under Voltage

    Likely cause
    Battery voltage is below acceptable limits.
    What to do
    Verify battery status and check connections.
  • 100030warning
    Manual (PDF)

    Battery discharge OCP

    Likely cause
    Over discharged battery
    What to do
    Reduce backup load; restart inverter if necessary.
  • 100058warningCall your installer
    Manual (PDF)

    Arc Fault Circuit Interrupter (AFCI) Check Failure

    Likely cause
    Processor checks indicate an issue.
    What to do
    Restart the system; confirm fault persists.
  • 100122warningCall your installer
    Manual (PDF)

    EEPROM Read/Write Failure

    Likely cause
    Remote upgrades or memory issues.
    What to do
    Contact service if issue persists.
  • 100145warningCall your installer
    Manual (PDF)

    12V Auxiliary Power Fault

    Likely cause
    Occasional issue; may recover automatically.
    What to do
    Monitor; contact service if persistent.
  • 110004warningCall your installer
    Manual (PDF)

    DC Power Alarm

    Likely cause
    Inverter in grid overvoltage state.
    What to do
    Check grid voltage settings; contact service for assistance.
  • 110022warningCall your installer
    Manual (PDF)

    Grid Volt Alarm

    Likely cause
    Abnormal grid voltage
    What to do
    Check grid integrity; adjust parameters if persistent.
  • 110036warningCall your installer
    Manual (PDF)

    Flash ID Alarm

    Likely cause
    System performance issue; may require inspection.
    What to do
    Contact service for confirmation.
  • 110037warningCall your installer
    Manual (PDF)

    Read Flash Alarm

    Likely cause
    Possible issue needing service.
    What to do
    Contact service.
  • 110039warningCall your installer
    Manual (PDF)

    Machine Type Alarm

    Likely cause
    Firmware does not match physical model.
    What to do
    Contact service for guidance.
  • 110048warningCall your installer
    Manual (PDF)

    No PV Input Alarm

    Likely cause
    Circuit abnormalities; check connections.
    What to do
    Contact service for diagnosis.
  • 110050warningCall your installer
    Manual (PDF)

    Output Power Limit Alarm

    Likely cause
    System needs assessment.
    What to do
    Restart if not resolved; contact service otherwise.
  • 110059warningCall your installer
    Manual (PDF)

    Grid Waveform Abnormal Alarm

    Likely cause
    Short-term grid fluctuations.
    What to do
    Monitor performance; contact service if unresolved.
  • 100012info
    Manual (PDF)

    PV Reverse

    Likely cause
    Incorrect connection of PV strings
    What to do
    Reconnect PV strings correctly.
  • 100041info
    Manual (PDF)

    Output DC over voltage

    Likely cause
    Short-term grid instability affecting inverter
    What to do
    No action required if resolves automatically; contact customer service for persistent issues.
  • 100046info
    Manual (PDF)

    DC Input Disturbance

    Likely cause
    Occasional issue; may recover automatically.
    What to do
    Monitor the situation.
  • 100052info
    Manual (PDF)

    Backup Over Voltage

    Likely cause
    Occasional issue; may recover automatically.
    What to do
    No action required, monitor the situation.
  • 100054info
    Manual (PDF)

    DC Bus Under Voltage

    Likely cause
    Occasional issue; may recover automatically.
    What to do
    Monitor the situation.
  • 110021infoCall your installer
    Manual (PDF)

    Grid Loss Alarm

    Likely cause
    Short-term grid fluctuation; may recover automatically.
    What to do
    Monitor and check connections if persistent.
  • 110023infoCall your installer
    Manual (PDF)

    Grid Frequency Alarm

    Likely cause
    Short-term grid fluctuation; may recover automatically.
    What to do
    Monitor for persistence; check connections.
  • 110040info
    Manual (PDF)

    Inverter Voltage Low Alarm

    Likely cause
    Low light conditions; possibly normal.
    What to do
    Verify; otherwise monitor.
  • 110049info
    Manual (PDF)

    Input Power Limit Alarm

    Likely cause
    Low light conditions; usually no action required.
    What to do
    Monitor, especially during operation.

More Alpha ESS Co Ltd inverters

SMILE-B5 (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 II (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 IV (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 V (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 VI (AS4777-2 2020)

5 kW · 1φ

SMILE-G3-B5-INV (AS4777-2 2020)

5 kW · 1φ

View all Alpha ESS Co Ltd inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?