Loading Solar Battery Perth...
Loading Solar Battery Perth...
Hybrid inverter · Yinergy Digital Power Technology · HI series · CEC approved June 2026
CEC listing: HI-1P4K-L-Y1 (AS4777-2 2020)
A 4 kW single-phase hybrid inverter that is battery-ready.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Rated power
How much solar it can turn into usable power at once
Phases
Runs on a standard single-phase supply
Type
Runs solar and a battery from one unit
Warranty
How long Yinergy Digital Power Technology Co Ltd stands behind it
Every figure on file for the Yinergy Digital Power Technology HI-1P4K-L-Y1, by section.
| Specification | Value |
|---|---|
| Physical | |
| IP rating | IP66 |
| Installation requirements | |
| Top clearance | 300 mm |
| Side clearance | 300 mm |
| AC breaker | 25 A |
| Cable gauge | 4 mm² |
| Earthing method | Class I |
| DNSP pre-approval | Yes |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Battery compatible
Yes
Backup capable
Yes
CEC approved
5 June 2026
Approval expiry
5 June 2029
Status
Active
Eligible for rebates
Yes
Years in AU Market
—
Australian Office
Not verified
CEC-Approved Batteries
0
CEC-Approved Panels
0
Category
Unknown
Typical installed, inverter only
$1,400–$2,400
Prices vary by installer, configuration and site complexity. Get exact quotes from installers you choose.
Compare quotes from installers you choose
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead — ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Yinergy Digital Power Technology HI-1P4K-L-Y1 against the closest-power inverters from other brands.
| Specification | Yinergy Digital Power Technology HI-1P4K-L-Y1Yinergy Digital Power Technology | Afore New Energy Technology AF4K-SLAfore New Energy Technology | Afore New Energy Technology HNS4000TLAfore New Energy Technology |
|---|---|---|---|
| Rated power? | 4 kW | 4 kW | 4 kW |
| Max efficiency? | 0.0% | 0.0% | 0.0% |
| MPPT trackers? | Not verified | Not verified | Not verified |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Hybrid | Hybrid | Solar |
| Battery ready | Yes | Yes | No |
| Warranty | 10 years | Not verified | Not verified |
Specs from the CEC register and datasheet enrichment. Indicative — confirm exact figures with your installer.
This warranty covers defects in materials and workmanship for ten years. Not covered: installations not per local codes. Claims can be made via an authorized dealer.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 70 of 70. The official install manual is the authoritative source — always confirm before acting.
ARM EEPROM FaultcriticalCall your installerThe manager eeprom is fault.
Bat Boost FaultcriticalCall your installerThe battery boost circuit mosfet is fail.
Bat Buck FaultcriticalCall your installerThe battery buck circuit mosfet is fail.
Bms ChgCur HighcriticalCall your installerBattery charge over current.
Bms ChgReq NoAckcriticalCall your installerNo action for charging request.
Bms DchgCur HighcriticalCall your installerBattery discharge over current.
Bms HW ProtectcriticalCall your installerBattery hardware under protection.
Bms Insul FaultcriticalCall your installerBattery insulation fault.
Bms M&S UnmatchcriticalCall your installerThe software between Master and Slave are not match.
Bms Mfg UnmatchcriticalCall your installerThe cell manufacture is different.
Bms Relay FaultcriticalCall your installerBattery relay fault.
Bms SwHw UnmatchcriticalCall your installerThe slave software and hardware are not match.
Bms Temp HighcriticalCall your installerBattery over temperature.
Bms Temp LowcriticalCall your installerBattery under temperature.
Bms Type UnmatchcriticalCall your installerThe capacity of battery packs is different.
Bms Ver UnmatchcriticalCall your installerThe software between slaves are different.
Bms Volt HighcriticalCall your installerBattery over voltage.
Bms Volt LowcriticalCall your installerBattery under voltage.
BmsCellImbalancecriticalCall your installerThe capacities of cells are different.
BmsCircuit FaultcriticalCall your installerBms hardware circuit fault.
BmsCurSen FaultcriticalCall your installerBattery current sensor fault.
BmsTempSen FaultcriticalCall your installerBattery temperature sensor fault.
BmsVoltsSen FaultcriticalCall your installerBattery voltage sensor fault.
Dci Cons FaultcriticalCall your installerThe dci sample value between master and slave is not consistent.
Eps Over LoadcriticalCall your installerOver load in off grid mode.
Eps Relay FaultcriticalCall your installerThe eps relay is failed.
GridF Cons FaultcriticalCall your installerThe grid frequency sample value between master and slave is not consistent.
GridV Cons FaultcriticalCall your installerThe grid voltage sample value between master and slave is not consistent.
Ground FaultcriticalCall your installerThe ground connection is failed.
Inv EEPROM FaultcriticalCall your installerThe inverter eeprom is fault.
Iso FaultcriticalCall your installerThe isolation is failed.
MDSP Smpl FaultcriticalCall your installerThe master sample detection circuit is failed.
MDSP SPI FaultcriticalCall your installerThe communication between master and slave is fail.
Over Load FaultcriticalCall your installerOver load in on grid mode.
Rc Cons FaultcriticalCall your installerThe residual current sample value between master and slave is not consistent.
RDSP Smpl FaultcriticalCall your installerThe slave sample detection circuit is failed.
RDSP SPI FaultcriticalCall your installerThe communication between master and slave is fail.
Res Cur FaultcriticalCall your installerThe residual current is high.
Res Cur HW FaultcriticalCall your installerResidual current detection device is failed.
SCI FaultcriticalCall your installerThe communication between master and manager is fail.
10min Volt FaultwarningThe grid voltage is out of range for the last 10 Minutes.
Bat Power LowwarningThe battery power is low.
Bat Relay OpenwarningCall your installerThe battery relay keeps open.
Bat Relay Short CircuitwarningCall your installerThe battery relay keeps close.
Bat Volt FaultwarningCall your installerBattery voltage fault.
BatCon Dir FaultwarningCall your installerThe battery connection is reversed.
Bms Ext FaultwarningCall your installerThe communication between BMS and Inverter is interrupted.
Bms Int FaultwarningCall your installerDIP switch at the wrong position; The communication between battery packs is interrupted.
BMS LostwarningCall your installerThe communication between BMS and Inverter is interrupted.
DCI FaultwarningCall your installerDC component is out of limit in output current.
Grid Freq FaultwarningGrid frequency out of range.
Grid Lost FaultwarningGrid is lost.
Grid Volt FaultwarningGrid voltage out of range.
HW Bat Cur FaultwarningCall your installerBattery current high detected by hardware.
HW Bus Vol FaultwarningCall your installerBus voltage out of range detected by hardware.
HW Inv Cur FaultwarningCall your installerOutput current high detected by hardware.
HW Pv Cur FaultwarningCall your installerPV input current high detected by hardware.
M1 Close FaultwarningCall your installerThe grid relay M1 keep close.
M2 Close FaultwarningCall your installerThe grid relay M2 keep close.
Main Relay OpenwarningCall your installerThe grid relay keeps open.
Meter Lost FaultwarningCall your installerThe communication between meter and Inverter is interrupted.
Pv Volt FaultwarningCall your installerPV voltage out of range.
PvCon Dir FaultwarningCall your installerThe PV connection is reversed.
S1 Close FaultwarningCall your installerThe grid relay S1 keep close.
S2 Close FaultwarningCall your installerThe grid relay S2 keep close.
SW Bat Cur FaultwarningCall your installerBattery current high detected by software.
SW Bus Vol FaultwarningCall your installerBus voltage out of range detected by software.
SW Inv Cur FaultwarningCall your installerOutput current high detected by software.
SW Pv Cur FaultwarningCall your installerPV input current high detected by software.
Temp FaultwarningThe inverter temperature is high.
Part of the Yinergy Digital Power Technology HI series
Compare every Yinergy Digital Power Technology HI variant side by side →
HI-1P3.68K-L-Y1 (AS4777-2 2020)
3.68 kW · 1φ
HI-1P3K-L-Y1 (AS4777-2 2020)
3 kW · 1φ
HI-1P4.6K-L-Y1 (AS4777-2 2020)
4.6 kW · 1φ
HI-1P5K-L-Y1 (AS4777-2 2020)
5 kW · 1φ
HI-1P6K-L-Y1 (AS4777-2 2020)
6 kW · 1φ
Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.