Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SMA
  4. STP 15-50

Solar inverter · SMA · CEC approved August 2026

SMA STP 15-50

CEC listing: STP 15-50 (AS4777-2 2020)

A 15 kW three-phase solar inverter.

Rated power
15kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

STP 15-50: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
15kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Solar
Runs solar only
Warranty
20yr
How long SMA Australia Pty Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the SMA STP 15-50, by section.

Full datasheet, by section
SpecificationValue
Efficiency
European efficiency98.2%
Physical
Weight35 kg
IP ratingIP65
Installation requirements
Cable gauge10 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
6 Aug 2026
Approval expiry
6 Feb 2027
Status
Active
Listed for STCs
Yes

About SMA

Years on the CEC list
20 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
33
CEC-approved batteries
1
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
63.8 kWh
Annual yield
23,269 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.sma-australia.com.au
20 years on the CEC list

How it compares

The SMA STP 15-50 against the closest-power inverters from other brands.

Specification
SMA STP 15-50SMA
Energizer Force 15.0HT+Energizer
Afore AF15K-THAfore
Rated power?15 kW15 kW15 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty20 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

20-year inverter warranty

SMA STP 15-50

This warranty covers the Sunny Tripower X solar inverters for five years, ensuring they function correctly. Exclusions include non-accredited installations and modifications; to claim, contact the installer directly.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation or modification of the product voids the warranty.
Environment limits
None stated
Read the official warranty document (PDF)

Fault & error codes — SMA STP 15-50

From the install manual

13 documented

Showing 13 of 13. The official install manual is the authoritative source — always confirm before acting.

  • 1001criticalCall your installer
    Manual (PDF)

    L/N swapped - Installation fault.

    Likely cause
    Incorrect installation of the L/N connection.
    What to do
    Check the AC wiring from the inverter to the feed-in meter.
  • 101criticalCall your installer
    Manual (PDF)

    Grid incident - Voltage too high.

    Likely cause
    The grid voltage or grid impedance at the connection point is too high.
    What to do
    Check the grid voltage at the connection point. If outside permissible range, contact the grid operator.
  • 102criticalCall your installer
    Manual (PDF)

    Grid incident - Voltage too high.

    Likely cause
    The grid voltage or grid impedance at the connection point is too high.
    What to do
    Check the grid voltage at the connection point. If outside permissible range, contact the grid operator.
  • 103criticalCall your installer
    Manual (PDF)

    Grid incident - Voltage too high.

    Likely cause
    The grid voltage or grid impedance at the connection point is too high.
    What to do
    Check the grid voltage at the connection point. If outside permissible range, contact the grid operator.
  • 105criticalCall your installer
    Manual (PDF)

    Grid incident - Voltage too high.

    Likely cause
    The grid voltage or grid impedance at the connection point is too high.
    What to do
    Check the grid voltage at the connection point. If outside permissible range, contact the grid operator.
  • 1101criticalCall your installer
    Manual (PDF)

    Installation fault - Check connection.

    Likely cause
    A second line conductor is connected to N.
    What to do
    Connect the neutral conductor to N.
  • 301criticalCall your installer
    Manual (PDF)

    Voltage too high.

    Likely cause
    The ten-minute average value of the grid voltage is no longer within the permissible range.
    What to do
    Check the grid voltage. If fluctuations occur frequently, contact the grid operator.
  • 401criticalCall your installer
    Manual (PDF)

    Grid incident - Disconnected.

    Likely cause
    A stand-alone grid or a very large change in the grid frequency was detected.
    What to do
    Check for power outages. Contact grid operator if needed.
  • 404criticalCall your installer
    Manual (PDF)

    Grid incident - Disconnected.

    Likely cause
    A stand-alone grid or a very large change in the grid frequency was detected.
    What to do
    Check for power outages. Contact grid operator if needed.
  • 501criticalCall your installer
    Manual (PDF)

    Grid frequency not permitted.

    Likely cause
    The grid frequency is not within the permissible range.
    What to do
    Check grid frequency. Contact grid operator if needed.
  • 302warningCall your installer
    Manual (PDF)

    Temperature AC voltage - Reduced power.

    Likely cause
    The inverter has reduced its power due to a too-high grid voltage.
    What to do
    Check grid voltage and its fluctuations. Contact grid operator if necessary.
  • 507warningCall your installer
    Manual (PDF)

    Too high grid frequency - Reduced power.

    Likely cause
    The inverter has reduced its power due to a too-high grid frequency.
    What to do
    Check grid frequency. Contact grid operator if needed.
  • 6001warningCall your installer
    Manual (PDF)

    Excess direct current detected.

    Likely cause
    Direct current in the grid current is too high.
    What to do
    Check the grid connection for direct current.

More SMA Australia Pty Ltd inverters

STP 12-50 (AS4777-2 2020)

12 kW · 3φ

STP10.0-3AV-40 (AS4777-2 2020)

10 kW · 3φ

STP 20-50 (AS4777-2 2020)

20 kW · 3φ

STP8.0-3AV-40 (AS4777-2 2020)

8 kW · 3φ

STP6.0-3AV-40 (AS4777-2 2020)

6 kW · 3φ

STP5.0-3AV-40 (AS4777-2 2020)

5 kW · 3φ

View all SMA Australia Pty Ltd inverters

More from SMA

Other CEC-approved products from SMA available in Australia.

SMA Batteries

HS-BM-3.28-10

3.28 kWh · LFP

View all SMA batteries
View full SMA manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?