Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sofar
  4. HYD 8KTL-3PH

Hybrid inverter · Sofar · CEC approved June 2025

Sofar HYD 8KTL-3PH

CEC listing: HYD 8KTL-3PH (AS4777-2 2020)

An 8 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

HYD 8KTL-3PH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

Is it right for your home?, Sofar HYD 8KTL-3PH

Sofar Solar's HYD series is a hybrid inverter line for homes adding a battery now or later. It comes in a single-phase version and a three-phase version.

The HYD works with Sofar's own batteries and with a list of third-party batteries. Live data runs through the SolarMan platform.

Pick the version that matches the home's supply.

What it does well

  • Works with Sofar and third-party batteries
  • Single-phase and three-phase versions
  • Compact installation

Where it falls short

  • Third-party batteries must be on Sofar's compatible list

A good fit for

  • Homes adding a battery now or later
  • Three-phase homes that want a hybrid

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Shenzhen SOFARSOLAR Co Ltd stands behind it

Full datasheet

Every figure on file for the Sofar HYD 8KTL-3PH, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power8 kW
Maximum power8.8 kW
Apparent power8 kVA
Phases3
Efficiency
Max efficiency98%
European efficiency97.5%
CEC-weighted efficiency97.6%
DC input & MPPT
MPPT trackers2
Max input voltage800 V
MPPT voltage min180 V
MPPT voltage max800 V
Max input current15 A
Battery & backup
Battery compatibleYes
Backup capableYes
Continuous backup8 kW
Physical
Dimensions (H×W×D)515 × 587 × 261 mm
Weight33 kg
IP ratingIP65
CoolingNatural
Operating temperature-30°C to 60°C
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
23 June 2025
Approval expiry
24 Mar 2027
Status
Active
Listed for STCs
Yes

About Sofar

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
126
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.sofarsolar.com
8 years on the CEC list

How it compares

The Sofar HYD 8KTL-3PH against the closest-power inverters from other brands.

Specification
Sofar HYD 8KTL-3PHSofar
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

5-year inverter warranty

Sofar HYD 8KTL-3PH

This warranty covers defects in materials and workmanship for five years. To make a claim, contact SOFAR. The warranty does not cover damage from improper installation or external environmental factors.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Improper installation, unauthorized repairs, and modifications void the warranty.
Environment limits
/
Read the official warranty document (PDF)

Fault & error codes — Sofar HYD 8KTL-3PH

From the install manual

13 documented

Showing 13 of 13. The official install manual is the authoritative source — always confirm before acting.

  • ID005criticalCall your installer
    Manual (PDF)

    Charge Leakage Fault

    Likely cause
    Check for inverter and wiring issues that could cause leakage.
    What to do
    Investigate and rectify leak issues. Immediate action required.
  • ID008criticalCall your installer
    Manual (PDF)

    Island protection fault

    Likely cause
    Inverter detected a condition that could lead to islanding.
    What to do
    Immediate inspection required. Disconnect from mains if safe to do so.
  • ID012criticalCall your installer
    Manual (PDF)

    Inverter overvoltage

    Likely cause
    Internal hardware issue leading to overvoltage condition.
    What to do
    Turn off the inverter immediately and contact the installer.
  • ID038criticalCall your installer
    Manual (PDF)

    Inverter failed to output

    Likely cause
    Inverter could not achieve nominal output status, possibly due to internal fault.
    What to do
    Switch off the inverter and contact your installer immediately for service.
  • ID001warningCall your installer
    Manual (PDF)

    The voltage of the power grid is too high

    Likely cause
    If the alarm occurs occasionally, the possible cause is that the electric grid is abnormal occasionally.
    What to do
    Monitor the grid status and check if the issue persists. If frequent, contact your installer.
  • ID002warningCall your installer
    Manual (PDF)

    The voltage of the mains is too low

    Likely cause
    The grid voltage has dropped below acceptable limits.
    What to do
    Monitor the grid status. If the issue continues, consult with your installer.
  • ID003warning
    Manual (PDF)

    The mains frequency is too high

    Likely cause
    Grid frequency is outside normal range, may indicate grid issues.
    What to do
    The inverter will automatically return to normal operating status when the electric grid's frequency returns to normal.
  • ID004warningCall your installer
    Manual (PDF)

    The mains frequency is too low

    Likely cause
    The grid frequency has dropped below acceptable limits.
    What to do
    Monitor the situation. If the issue persists, contact your installer.
  • ID006warningCall your installer
    Manual (PDF)

    OVRT function is faulty

    Likely cause
    Grid anomalies causing the overvoltage ride-through protection to fail.
    What to do
    Monitor the grid conditions. If frequent, consult your installer.
  • ID007warningCall your installer
    Manual (PDF)

    LVRT function is faulty

    Likely cause
    Low voltage ride-through issues indicating grid problems.
    What to do
    Monitor situations with low grid voltage. Report to installer if issues repeat.
  • ID009warning
    Manual (PDF)

    Transient overvoltage of mains voltage 1

    Likely cause
    Spikes in system voltage detected.
    What to do
    Monitor for recurring issues, review system design if needed.
  • ID010warningCall your installer
    Manual (PDF)

    Transient overvoltage of mains voltage 2

    Likely cause
    Potential spikes in system voltage detected externally.
    What to do
    Monitor for recurring issues, discuss possible corrective actions with installer.
  • ID011warningCall your installer
    Manual (PDF)

    Power grid line voltage error

    Likely cause
    Voltage discrepancies detected on the grid connection.
    What to do
    Watch grid voltage levels, reach out to the installer if issues continue.

More Shenzhen SOFARSOLAR Co Ltd inverters

ESI-8K-T1 (AS4777-2 2020)

8 kW · 3φ

ESI-6.5K-T1 (AS4777-2 2020)

6.5 kW · 3φ

ESI-9.9K-T1-A (AS4777-2 2020)

9.9 kW · 3φ

ESI-9.99K-T1-A (AS4777-2 2020)

9.99 kW · 3φ

ESI-6K-T1 (AS4777-2 2020)

6 kW · 3φ

HYD 6KTL-3PH (AS4777-2 2020)

6 kW · 3φ

View all Shenzhen SOFARSOLAR Co Ltd inverters

More from Sofar

Other CEC-approved products from Sofar available in Australia.

Sofar Batteries

BTS 5K

4.992 kWh · LFP

BTS E10-DS5

9.984 kWh · LFP

BTS E15-DS5

14.976 kWh · LFP

BTS E20-DS5

19.968 kWh · LFP

BTS E5-DS5

4.992 kWh · LFP

BTS 5K

4.75 kWh

View all Sofar batteries
View full Sofar manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?