Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sofar
  4. ESI-6.5K-T1

Hybrid inverter · Sofar · CEC approved May 2026

Sofar ESI-6.5K-T1

CEC listing: ESI-6.5K-T1 (AS4777-2 2020)

A 6.5 kW three-phase hybrid inverter that is battery-ready.

Rated power
6.5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

ESI-6.5K-T1: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6.5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Shenzhen SOFARSOLAR Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Sofar ESI-6.5K-T1, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP66
Operating temperature25°C to 60°C
Installation requirements
Top clearance30 mm
Side clearance30 mm
AC breaker20 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
28 May 2026
Approval expiry
28 May 2029
Status
Active
Listed for STCs
Yes

About Sofar

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
126
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
27.6 kWh
Annual yield
10,083 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.sofarsolar.com
8 years on the CEC list

How it compares

The Sofar ESI-6.5K-T1 against the closest-power inverters from other brands.

Specification
Sofar ESI-6.5K-T1Sofar
Must PH11-6.5KL3 EUMust
FoxESS AIO-H1-6.0-HVS10.4FoxESS
Rated power?6.5 kW6.5 kW6.6 kW✓highest
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseSingle-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Sofar ESI-6.5K-T1

The warranty covers manufacturing defects for 10 years. Capacity must remain above 80% at year 10. It does not cover non-accredited installations. Claims can be made via the support contact.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, or tampering with device.
Environment limits
Extremes such as salt spray or temperatures above 60°C.
Read the official warranty document (PDF)

Fault & error codes — Sofar ESI-6.5K-T1

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • 001critical
    Manual (PDF)

    Grid voltage is too high

    Likely cause
    Temporary abnormality in the electric grid; could indicate grid issues.
    What to do
    Monitor the grid; inverter will return to normal upon grid recovery.
  • 002critical
    Manual (PDF)

    Grid voltage is too low

    Likely cause
    Can occur during grid instability; monitor voltage levels.
    What to do
    Wait for the grid to return to normal; inverter will automatically resume operation.
  • 003critical
    Manual (PDF)

    Grid frequency is too high

    Likely cause
    Can be due to grid issues or faults; requires monitoring.
    What to do
    Inverter will reset automatically when the grid frequency normalizes.
  • 004critical
    Manual (PDF)

    Grid frequency is too low

    Likely cause
    Indicates potential grid instability; requires attention.
    What to do
    Check grid settings; inverter will return to normal when frequency stabilizes.
  • 005criticalCall your installer
    Manual (PDF)

    Charge leakage fault

    Likely cause
    Potential electrical fault or wiring issue.
    What to do
    Disconnect power and inspect wiring; seek technical assistance.
  • 008critical
    Manual (PDF)

    Island protection fault

    Likely cause
    Could indicate a disconnection from grid power.
    What to do
    Check grid connection; inverter will return to normal once grid is detected.
  • 012criticalCall your installer
    Manual (PDF)

    Inverter overvoltage

    Likely cause
    High input voltage; may require checking PV arrangements.
    What to do
    Switch off inverter, wait for 5 minutes, then switch back on.
  • 013criticalCall your installer
    Manual (PDF)

    Feed-in Limit function is faulty

    Likely cause
    Internal error within the inverter, requiring reset.
    What to do
    Switch off the inverter, wait 5 minutes and power it back on; if error persists, contact support.
  • 032criticalCall your installer
    Manual (PDF)

    Neutral ground fault

    Likely cause
    Electrical imbalance or faulty wiring; check ground connections.
    What to do
    Inspect connections, ensure proper grounding; contact installer if unclear.
  • 042criticalCall your installer
    Manual (PDF)

    Insulation resistance is too low

    Likely cause
    Possible short circuit or damaged insulation.
    What to do
    Check for short circuits in PV array; rectify before continuing use.
  • 066criticalCall your installer
    Manual (PDF)

    Transient value of bus voltage is unbalanced

    Likely cause
    Potential internal issues; requires attention.
    What to do
    Switch off inverter, wait 5 minutes, then switch back on; contact support if error persists.

More Shenzhen SOFARSOLAR Co Ltd inverters

ESI-6K-T1 (AS4777-2 2020)

6 kW · 3φ

HYD 6KTL-3PH (AS4777-2 2020)

6 kW · 3φ

ESI-5K-T1 (AS4777-2 2020)

5 kW · 3φ

HYD 5KTL-3PH (AS4777-2 2020)

5 kW · 3φ

ESI-8K-T1 (AS4777-2 2020)

8 kW · 3φ

HYD 8KTL-3PH (AS4777-2 2020)

8 kW · 3φ

View all Shenzhen SOFARSOLAR Co Ltd inverters

More from Sofar

Other CEC-approved products from Sofar available in Australia.

Sofar Batteries

BTS 5K

4.992 kWh · LFP

BTS E10-DS5

9.984 kWh · LFP

BTS E15-DS5

14.976 kWh · LFP

BTS E20-DS5

19.968 kWh · LFP

BTS E5-DS5

4.992 kWh · LFP

BTS 5K

4.75 kWh

View all Sofar batteries
View full Sofar manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?