CEC listing: Isuna D9.9K-SL-S-AU (AS4777-2 2020)
A 9.9 kW single-phase hybrid inverter that is battery-ready.
- Rated power
- 9.9kW
- How much solar it can run at once
- Battery-ready
- Yes
- A battery plugs straight in
- Feed-in credits (DEBS)
- No
- DEBS pays for exports only when the inverter is 5 kW or less
Key specs, in plain terms
The numbers that matter for a home. The full datasheet is below.
- Rated power
- 9.9kW
- How much solar it can turn into usable power at once
- Max efficiency
- Not on file: we don't have this figure from the manufacturer's documents yet
- How much of the solar you make reaches the house
- Phases
- Single
- Runs on a standard single-phase supply
- Type
- Hybrid
- Runs solar and a battery from one unit
- Warranty
- 5yr
- How long Shenzhen Sinexcel Isuna Energy Technology Co Ltd stands behind it
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
What we can tell you
Read from the figures on this page. No review written yet.
- It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
- It runs on a standard single-phase supply.
- This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.
- It is CEC-approved, which a new install needs to qualify for STCs.
Features and CEC approval
- Battery compatible
- Yes
- Backup capable
- Yes
- CEC approved
- 1 Oct 2026
- Approval expiry
- 1 Oct 2029
- Status
- Active
- Listed for STCs
- Yes
About Shenzhen Sinexcel Isuna Energy Technology
- Years on the CEC list
- 1 years
- Australian office
- Not verified
- Category
- Budget
- CEC-approved inverters
- 34
Documents
WA compliance
- Synergy's list
- Not listed
- Remote management
- No record
This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.
Perth performance
Estimate for a full-size array on this inverter
- Daily yield
- 42.1 kWh
- Annual yield
- 15,357 kWh
At 5 peak sun hours a day (BOM) with a 15% system derate.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Full datasheet
Every figure on file for the Shenzhen Sinexcel Isuna Energy Technology Isuna D9.9K-SL-S-AU, by section.
| Specification | Value |
|---|---|
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| Top clearance | 1200 mm |
| Side clearance | 300 mm |
| AC breaker | 80 A |
| Cable gauge | 35 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | Yes |
| Estimated install time | 6 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
How it compares
The Shenzhen Sinexcel Isuna Energy Technology Isuna D9.9K-SL-S-AU against the closest-power inverters from other brands.
| Specification | Shenzhen Sinexcel Isuna Energy Technology Isuna D9.9K-SL-S-AUShenzhen Sinexcel Isuna Energy Technology | Energizer Force 9.9HS+Energizer | Energizer Force 9.9HT+Energizer |
|---|---|---|---|
| Rated power? | 9.9 kW | 9.9 kW | 9.9 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
5-year inverter warranty
Shenzhen Sinexcel Isuna Energy Technology Isuna D9.9K-SL-S-AUThis warranty covers defects in materials and workmanship for 5 years, but does not include damages from improper installation or modification. Claims can be made via customer support.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
- Coverage shape
- Full-replacement coverage
- If you sell the home
- Transfers to the next homeowner
- What voids it
- Non-accredited installation, modification, or tampering voids the warranty.
- Environment limits
- , recommended max operating temperature is 40°C
Fault & error codes — Shenzhen Sinexcel Isuna Energy Technology Isuna D9.9K-SL-S-AU
From the install manual
Showing 7 of 7. The official install manual is the authoritative source — always confirm before acting.
- Manual (PDF)
28criticalCall your installerInsulation fault
- Likely cause
- Check PV string insulation resistance to ground.
- What to do
- Locate and fix the short circuit. Check inverter PGND connection. Reset the impedance protection point in persistently humid conditions.
- Manual (PDF)
29criticalCall your installerLeakage protection failure
- Likely cause
- Possible issue with the leakage protection system.
- What to do
- Disconnect all AC and DC breakers. Wait at least 5 minutes, then reclosing the breakers. If the fault persists, contact support.
- Manual (PDF)
30criticalCall your installerModel Capacity Fault
- Likely cause
- Inverter firmware or settings issue.
- What to do
- Contact your distributor or service center to check APP parameter settings or perform a software upgrade.
- Manual (PDF)
4criticalPV 1/2/3 reverse connection
- Likely cause
- PV positive and negative terminals are reversed.
- What to do
- Check and correct the PV polarity, then restart the inverter.
- Manual (PDF)
22warningCall your installerGrid voltage anomaly
- Likely cause
- Occasional alarms may show temporary grid issues; the inverter will auto-sync when grid stabilizes.
- What to do
- Frequent alarms require checking grid quality, AC breaker, and cable connections. If connections are correct but alarms persist, contact support to adjust protection settings.
- Manual (PDF)
26warningAmbient temperature is too high
- Likely cause
- Ensure the inverter is installed away from direct sunlight.
- What to do
- Restart after the heatsink cools below 60°C and a 5-minute wait. If the fault persists, contact support.
- Manual (PDF)
27warningThe inverter is overheated.
- Likely cause
- Ensure the inverter is installed away from direct sunlight.
- What to do
- Restart after the heatsink cools below 60°C and a 5-minute wait. If the fault persists, contact support.
More Shenzhen Sinexcel Isuna Energy Technology inverters
Isuna D9.9K-SL-AU (AS4777-2 2020)
9.9 kW · 1φ
Isuna D10K-SL-AU (AS4777-2 2020)
10 kW · 1φ
Isuna D10K-SL-S-AU (AS4777-2 2020)
10 kW · 1φ
Isuna D8K-SL-AU (AS4777-2 2020)
8 kW · 1φ
Isuna D8K-SL-S-AU (AS4777-2 2020)
8 kW · 1φ
Isuna D12K-SL-AU (AS4777-2 2020)
12 kW · 1φ
Want to take the next step?
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.