Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AU
CEC listing: Isuna D10K-SL-AU (AS4777-2 2020)
A 10 kW single-phase hybrid inverter that is battery-ready.
- Rated power
- 10kW
- A large roof
- Battery-ready
- Yes
- A battery plugs straight in
- Feed-in credits (DEBS)
- No
- DEBS pays for exports only when the inverter is 5 kW or less
Key specs, in plain terms
The numbers that matter for a home. The full datasheet is below.
- Rated power
- 10kW
- How much solar it can turn into usable power at once
- Max efficiency
- Not on file: we don't have this figure from the manufacturer's documents yet
- How much of the solar you make reaches the house
- Phases
- Single
- Runs on a standard single-phase supply
- Type
- Hybrid
- Runs solar and a battery from one unit
- Warranty
- 5yr
- How long Shenzhen Sinexcel Isuna Energy Technology Co Ltd stands behind it
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
What we can tell you
Read from the figures on this page. No review written yet.
- It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
- It runs on a standard single-phase supply.
- This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.
- It is CEC-approved, which a new install needs to qualify for STCs.
Features and CEC approval
- Battery compatible
- Yes
- Backup capable
- Yes
- CEC approved
- 1 Oct 2026
- Approval expiry
- 1 Oct 2029
- Status
- Active
- Listed for STCs
- Yes
About Shenzhen Sinexcel Isuna Energy Technology
- Years on the CEC list
- 1 years
- Australian office
- Not verified
- Category
- Budget
- CEC-approved inverters
- 34
Documents
WA compliance
- Synergy's list
- Not listed
- Remote management
- No record
This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.
Perth performance
Estimate for a full-size array on this inverter
- Daily yield
- 42.5 kWh
- Annual yield
- 15,513 kWh
At 5 peak sun hours a day (BOM) with a 15% system derate.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Full datasheet
Every figure on file for the Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AU, by section.
| Specification | Value |
|---|---|
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| Top clearance | 1200 mm |
| Side clearance | 300 mm |
| AC breaker | 125 A |
| Cable gauge | 6 mm² |
| Earthing method | Non-grounded PV array, PE to earth ground |
| DNSP pre-approval | No |
| Estimated install time | 3 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
How it compares
The Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AU against the closest-power inverters from other brands.
| Specification | Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AUShenzhen Sinexcel Isuna Energy Technology | Energizer Force 10.0HS+Energizer | Energizer Force 10.0HT+Energizer |
|---|---|---|---|
| Rated power? | 10 kW | 10 kW | 10 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
5-year inverter warranty
Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AUSinexcel Isuna offers a 5-year limited warranty on inverters, covering defects not caused by improper installation or misuse. Claims can be filed through the local distributor or directly on their website.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
- Coverage shape
- Full-replacement coverage
- If you sell the home
- Transfers to the next homeowner
- What voids it
- non-accredited installation, modifications, tampering, usage outside safety regulations, normal wear and tear.
- Environment limits
- rust due to harsh environmental conditions, exposure to saltwater or aggressive atmospheres without prior approval.
Fault & error codes — Shenzhen Sinexcel Isuna Energy Technology Isuna D10K-SL-AU
From the install manual
Showing 8 of 8. The official install manual is the authoritative source — always confirm before acting.
- Manual (PDF)
25criticalCall your installerHeat sink is too high
- Likely cause
- Ensure the inverter is installed away from direct sunlight.
- What to do
- Restart after the heatsink cools below 60°C and a 5-minute wait. If the fault persists, contact support.
- Manual (PDF)
28criticalCall your installerInsulation fault
- Likely cause
- Check PV string insulation resistance to ground.
- What to do
- Locate and fix the short circuit. The impedance protection point can be reset in persistently humid conditions.
- Manual (PDF)
29criticalCall your installerLeakage protection failure
- Likely cause
- Contact your distributor or service center.
- What to do
- Disconnect all AC and DC breakers.
- Manual (PDF)
22warningGrid voltage anomaly
- Likely cause
- Occasional alarms may show temporary grid issues.
- What to do
- The inverter will auto-sync when grid stabilizes. Frequent alarms require checking grid quality.
- Manual (PDF)
23warningNetwork frequency anomaly
- Likely cause
- Occasional alarms may show temporary grid issues.
- What to do
- The inverter will auto-sync when grid stabilizes. Frequent alarms require checking grid quality.
- Manual (PDF)
26warningAmbient temperature is too high
- Likely cause
- Ensure the inverter is installed away from direct sunlight.
- What to do
- Restart after the heatsink cools below 60°C and a 5-minute wait. If the fault persists, contact support.
- Manual (PDF)
34warningParallel Communication Alarm
- Likely cause
- Check parallel communication cable sequencing and parameter settings in the APP.
- What to do
- For parallel systems only, ensure settings are correct and cables are connected properly.
- Manual (PDF)
35warningMeter Reversed
- Likely cause
- Check the meter wiring connections.
- What to do
- Correct the meter wiring connections.
More Shenzhen Sinexcel Isuna Energy Technology inverters
Isuna D10K-SL-S-AU (AS4777-2 2020)
10 kW · 1φ
Isuna D9.9K-SL-AU (AS4777-2 2020)
9.9 kW · 1φ
Isuna D9.9K-SL-S-AU (AS4777-2 2020)
9.9 kW · 1φ
Isuna D8K-SL-AU (AS4777-2 2020)
8 kW · 1φ
Isuna D8K-SL-S-AU (AS4777-2 2020)
8 kW · 1φ
Isuna D12K-SL-AU (AS4777-2 2020)
12 kW · 1φ
Want to take the next step?
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.