Solar inverter · Growatt · MOD series · CEC approval expired
CEC listing: MOD 8000TL3-X-AU (AS4777-2 2020)
An 8 kW single-phase solar inverter.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Growatt MOD 8000TL3-X-AU, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 5 kW |
| Maximum power | 10 kW |
| Apparent power | 10 kVA |
| Phases | 1 |
| Efficiency | |
| Max efficiency | 98% |
| European efficiency | 97% |
| CEC-weighted efficiency | 96% |
| DC input & MPPT | |
| MPPT trackers | 2 |
| Max input voltage | 1100 V |
| MPPT voltage min | 140 V |
| MPPT voltage max | 1000 V |
| Max input current | 16 A |
| Battery & backup | |
| Battery compatible | No |
| Backup capable | No |
| Continuous backup | 0 kW |
| Physical | |
| Dimensions (H×W×D) | 387 × 425 × 147 mm |
| Weight | 12.5 kg |
| IP rating | IP66 |
| Cooling | Natural convection |
| Operating temperature | -25°C to 60°C |
| Installation requirements | |
| Cable gauge | 8 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
www.growatt.com.auThe Growatt MOD 8000TL3-X-AU against the closest-power inverters from other brands.
| Specification | Growatt MOD 8000TL3-X-AUGrowatt | Energizer Force 8.0HS+Energizer | Energizer Force 8.0HT+Energizer |
|---|---|---|---|
| Rated power? | 8 kW | 8 kW | 8 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Solar | Hybrid | Hybrid |
| Battery ready | No | Yes | Yes |
| Warranty | Not on file | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
Warranty summary
This warranty covers defects in materials and workmanship for 10 years. It excludes any damages caused by non-accredited installations or modifications.
This warranty covers defects in materials and workmanship for 10 years. It excludes any damages caused by non-accredited installations or modifications.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.
Error 200criticalCall your installerAFCI Fault
Error 201criticalCall your installerLeakage current too high.
Error 202criticalCall your installerThe DC input voltage is exceeding the maximum tolerable value.
Error 203criticalCall your installerPV isolation Low
Error 300criticalCall your installerAC V Outrange
Error 303criticalCall your installerNE abnormal
Error 401criticalCall your installerDC Voltage High Fault
Error 402criticalCall your installerOutput DC current too high.
Error 304warningAC F Outrange
Error 410warningCommunication board and control panel sampling battery voltage is inconsistent.
Error 400infoFan function abnormal
MIN 8000TL-X (AS4777-2 2020)
8 kW · 1φ
MIN 8000TL-X(E) (AS4777-2 2020)
8 kW · 1φ
MIN 8000TL-X2 (AS4777-2 2020)
8 kW · 1φ
SPM 8000TL-HU (AS4777-2 2020)
8 kW · 1φ
MIN 7000TL-X (AS4777-2 2020)
7 kW · 1φ
MIN 7000TL-X(E) (AS4777-2 2020)
7 kW · 1φ
Other CEC-approved products from Growatt available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.