Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Growatt
  4. MOD 4000TL3-XH

Hybrid inverter · Growatt · CEC approved July 2023

Growatt MOD 4000TL3-XH

CEC listing: MOD 4000TL3-XH (AS4777-2 2020)

A 4 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
4kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MOD 4000TL3-XH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
4kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Shenzhen Growatt New Energy Co Ltd stands behind it

Full datasheet

Every figure on file for the Growatt MOD 4000TL3-XH, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power4 kW
Maximum power8 kW
Apparent power8 kVA
Phases1
Efficiency
Max efficiency98%
European efficiency97%
CEC-weighted efficiency96%
DC input & MPPT
MPPT trackers2
Max input voltage1100 V
MPPT voltage min140 V
MPPT voltage max1000 V
Max input current16 A
Battery & backup
Battery compatibleNo
Backup capableNo
Continuous backup0 kW
Physical
Dimensions (H×W×D)387 × 425 × 147 mm
Weight12.5 kg
IP ratingIP66
CoolingNatural convection
Operating temperature-25°C to 60°C
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Cable gauge8 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
No
CEC approved
25 July 2023
Approval expiry
21 Jan 2027
Status
Active
Listed for STCs
Yes

About Growatt

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
132
CEC-approved batteries
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
17.0 kWh
Annual yield
6,205 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.growatt.com.au
12 years on the CEC list

How it compares

The Growatt MOD 4000TL3-XH against the closest-power inverters from other brands.

Specification
Growatt MOD 4000TL3-XHGrowatt
Afore AF4K-SLAfore
Afore HNS4000TLAfore
Rated power?4 kW4 kW4 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

5-year inverter warranty

Growatt MOD 4000TL3-XH

This warranty covers defects in materials and workmanship for 10 years. It excludes any damages caused by non-accredited installations or modifications.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Warranty void if installation is not performed by accredited professionals or if product is modified.
Read the official warranty document (PDF)

Fault & error codes — Growatt MOD 4000TL3-XH

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • Error 200criticalCall your installer
    Manual (PDF)

    AFCI Fault

    Likely cause
    Check the panel terminal.
    What to do
    After shutdown, Check the panel terminal. Restart inverter. If error message still exists, contact manufacturer.
  • Error 201criticalCall your installer
    Manual (PDF)

    Leakage current too high.

    Likely cause
    Residual current detection activated.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 202criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value.

    Likely cause
    Check DC input voltage.
    What to do
    Immediately disconnect the DC switch and check the voltage. If the fault code still exists after the normal voltage is restored, contact manufacturer.
  • Error 203criticalCall your installer
    Manual (PDF)

    PV isolation Low

    Likely cause
    Check if the panel shell is reliably grounded.
    What to do
    After shutdown, check whether the panel shell is reliably grounded. If error message still exists, contact manufacturer.
  • Error 300criticalCall your installer
    Manual (PDF)

    AC V Outrange

    Likely cause
    Grid voltage is out of range.
    What to do
    Check grid voltage. If the error message still exists despite the grid voltage being within the tolerable range, contact manufacturer.
  • Error 303criticalCall your installer
    Manual (PDF)

    NE abnormal

    Likely cause
    Check PE, to ensure that the PE line contact is good.
    What to do
    If error message still exists, contact Manufacturer.
  • Error 401criticalCall your installer
    Manual (PDF)

    DC Voltage High Fault

    Likely cause
    Check the DC voltage input.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 402criticalCall your installer
    Manual (PDF)

    Output DC current too high.

    Likely cause
    Check the output load.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 304warning
    Manual (PDF)

    AC F Outrange

    Likely cause
    Check the AC frequency is out of range.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 410warning
    Manual (PDF)

    Communication board and control panel sampling battery voltage is inconsistent.

    Likely cause
    Inconsistent voltage readings.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 400info
    Manual (PDF)

    Fan function abnormal

    Likely cause
    Check the fan connection.
    What to do
    After shutdown, check the fan connection. If error message still exists, contact manufacturer.

More Shenzhen Growatt New Energy Co Ltd inverters

Growatt SPH4000 (AS4777-2 2020)

4 kW · 1φ

MOD 4000TL3-X (AS4777-2 2020)

4 kW · 1φ

SPA 4000TL-AU (AS4777-2 2020)

4 kW · 1φ

SPA 4000TL-AUB (AS4777-2 2020)

4 kW · 1φ

SPH 4000TL BL-UP (AS4777-2 2020)

4 kW · 1φ

SPH 4000TL-HU (AS4777-2 2020)

4 kW · 1φ

View all Shenzhen Growatt New Energy Co Ltd inverters

More from Growatt

Other CEC-approved products from Growatt available in Australia.

Growatt Batteries

ALP 10.0L-E1

10 kWh · LFP

ALP 10.0L-E2

10 kWh · LFP

ALP 15.0L-E1

15 kWh · LFP

ALP 15.0L-E2

15 kWh · LFP

ALP 20.0L-E1

20 kWh · LFP

ALP 20.0L-E2

20 kWh · LFP

View all Growatt batteries
View full Growatt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?