Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Shenzhen Enjoy Technology
  4. EPCS105-AM

Battery inverter · Shenzhen Enjoy Technology · CEC approved May 2026

Shenzhen Enjoy Technology EPCS105-AM

CEC listing: EPCS105-AM (AS4777-2 2020)

A 105 kW three-phase battery inverter.

Rated power
105kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter

Commercial-scale inverter

At 105 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
105kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
10yr
How long Shenzhen Enjoy Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Shenzhen Enjoy Technology EPCS105-AM, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Top clearance250 mm
Side clearance250 mm
AC breaker3 A
Cable gauge2.5 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
26 May 2026
Approval expiry
26 May 2029
Status
Active
Listed for STCs
Yes

About Shenzhen Enjoy Technology

Australian office
Not verified
Category
Unknown
CEC-approved inverters
7
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

0 years on the CEC list

How it compares

The Shenzhen Enjoy Technology EPCS105-AM against the closest-power inverters from other brands.

Specification
Shenzhen Enjoy Technology EPCS105-AMShenzhen Enjoy Technology
PotisEdge PotisPCS-105K-1000/400E-A02EPotisEdge
PotisEdge PotisPCS-105K-1000/400E-A02E-FPotisEdge
Rated power?105 kW105 kW105 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeBatteryBatteryBattery
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

10-year inverter warranty

Shenzhen Enjoy Technology EPCS105-AM

The product has a 5-year standard warranty and a 10-year extended warranty. Warranty is void for non-accredited installations. Claims can be initiated via the manufacturer’s website.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modification, or tampering voids warranty.
Environment limits
Operating temperature -20° to 55°C.
Read the official warranty document (PDF)

Fault & error codes — Shenzhen Enjoy Technology EPCS105-AM

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    HVDC link voltage error detected by software

    Likely cause
    HVDC link voltage exceeds the operational limits
    What to do
    Check HVDC link voltage and ensure it is within limits
  • 10criticalCall your installer
    Manual (PDF)

    LVDC link voltage error detected by hardware

    Likely cause
    Detection of a hardware fault in voltage regulation
    What to do
    Inspect hardware connections and functionality
  • 11criticalCall your installer
    Manual (PDF)

    HVDC link overcurrent detected by hardware

    Likely cause
    Detection of hardware fault indicating excessive current
    What to do
    Reduce load and check for potential faults
  • 2criticalCall your installer
    Manual (PDF)

    LVDC link voltage error detected by software

    Likely cause
    LVDC link voltage exceeds the operational limits
    What to do
    Check LVDC link voltage and ensure it is within limits
  • 3criticalCall your installer
    Manual (PDF)

    HVDC link overcurrent detected by software

    Likely cause
    Current in the HVDC link exceeds its maximum rating
    What to do
    Reduce load on HVDC link and check for faults
  • 5criticalCall your installer
    Manual (PDF)

    Overheating error

    Likely cause
    Unit temperature exceeds safe operating limits due to insufficient cooling
    What to do
    Allow the unit to cool down and check cooling system
  • 7criticalCall your installer
    Manual (PDF)

    Earth fault in HVDC link

    Likely cause
    Ground fault detected in HVDC circuitry
    What to do
    Disconnect power and check for grounding issues
  • 9criticalCall your installer
    Manual (PDF)

    HVDC link voltage error detected by hardware

    Likely cause
    Detection of a hardware fault in voltage regulation
    What to do
    Inspect hardware connections and functionality
  • 4warningCall your installer
    Manual (PDF)

    Internal error 1

    Likely cause
    General internal system error
    What to do
    Reset the device and check functionality
  • 6warningCall your installer
    Manual (PDF)

    Error when HVDC link is switched ON (for Autonomous Mode)

    Likely cause
    Improper switching sequence or malfunction during startup
    What to do
    Check and follow startup procedures carefully
  • 8warningCall your installer
    Manual (PDF)

    Internal error 2

    Likely cause
    General system malfunction
    What to do
    Reset the device and check functionality

More Shenzhen Enjoy Technology Co Ltd inverters

EPCS105-AM-F (AS4777-2 2020)

105 kW · 3φ

EPCS100-AM (AS4777-2 2020)

100 kW · 3φ

EPCS100-AM-F (AS4777-2 2020)

100 kW · 3φ

EPCS125-AM (AS4777-2 2020)

125 kW · 3φ

EPCS125-AM-F (AS4777-2 2020)

125 kW · 3φ

EPCS125-AM2S-M (AS4777-2 2020)

125 kW · 3φ

View all Shenzhen Enjoy Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?