Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Shenzhen Atess Power Technology
  4. PCS630

Battery inverter · Shenzhen Atess Power Technology · CEC approved January 2024

Shenzhen Atess Power Technology PCS630

CEC listing: PCS630 (AS4777-2 2020)

A 630 kW three-phase battery inverter.

Rated power
630kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter

Commercial-scale inverter

At 630 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
630kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
Not on file: we don't have this figure from the manufacturer's documents yet
How long Shenzhen Atess Power Technology Co Ltd stands behind it

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Shenzhen Atess Power Technology PCS630, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP00
Operating temperature0°C to 50°C
Installation requirements
Cable gauge70 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
2 Jan 2024
Approval expiry
2 Jan 2027
Status
Active
Listed for STCs
Yes

About Shenzhen Atess Power Technology

Years on the CEC list
4 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
9
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

4 years on the CEC list

How it compares

The Shenzhen Atess Power Technology PCS630 against the closest-power inverters from other brands.

Specification
Shenzhen Atess Power Technology PCS630Shenzhen Atess Power Technology
Eaton Power Quality 93PCS 630Eaton Power Quality
Eaton Power Quality 93PCS 500Eaton Power Quality
Rated power?630 kW✓highest630 kW✓highest500 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeBatteryBatteryBattery
Battery readyYesYesYes
WarrantyNot on fileNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

Warranty summary

The warranty covers defects in materials and workmanship under normal use. Important exclusions include damage from improper installation or modifications, and the warranty may not cover extreme environmental conditions.

Inverter warranty

Shenzhen Atess Power Technology PCS630

The warranty covers defects in materials and workmanship under normal use. Important exclusions include damage from improper installation or modifications, and the warranty may not cover extreme environmental conditions.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
Read the official warranty document (PDF)

Fault & error codes — Shenzhen Atess Power Technology PCS630

From the install manual

10 documented

Showing 10 of 10. The official install manual is the authoritative source — always confirm before acting.

  • AC OVER FREQcriticalCall your installer
    Manual (PDF)

    AC Over Frequency

    Likely cause
    Frequency of the AC supply is too high
    What to do
    Monitor frequency and consult an electrician if the issue persists
  • AC OVP RcriticalCall your installer
    Manual (PDF)

    AC Phase R Over Voltage

    Likely cause
    AC voltage exceeds safe operating limits for phase R
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • AC OVP ScriticalCall your installer
    Manual (PDF)

    AC Phase S Over Voltage

    Likely cause
    AC voltage exceeds safe operating limits for phase S
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • AC OVP TcriticalCall your installer
    Manual (PDF)

    AC Phase T Over Voltage

    Likely cause
    AC voltage exceeds safe operating limits for phase T
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • AC UNDER FREQcriticalCall your installer
    Manual (PDF)

    AC Under Frequency

    Likely cause
    Frequency of the AC supply is too low
    What to do
    Monitor frequency and consult an electrician if the issue persists
  • AC UVP RcriticalCall your installer
    Manual (PDF)

    AC Phase R Under Voltage

    Likely cause
    AC voltage is inadequate for phase R
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • AC UVP ScriticalCall your installer
    Manual (PDF)

    AC Phase S Under Voltage

    Likely cause
    AC voltage is inadequate for phase S
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • AC UVP TcriticalCall your installer
    Manual (PDF)

    AC Phase T Under Voltage

    Likely cause
    AC voltage is inadequate for phase T
    What to do
    Check AC supply voltage and consult an electrician if the issue persists
  • PHASE SEQ ERRcriticalCall your installer
    Manual (PDF)

    AC Phase Sequence Error

    Likely cause
    Incorrect phase sequence detected
    What to do
    Check phase configuration and rectify
  • PLL LOSTcriticalCall your installer
    Manual (PDF)

    Synchronize Fault (PLL)

    Likely cause
    The system has lost synchronization with the grid
    What to do
    Consult an electrician to restore synchronization

More Shenzhen Atess Power Technology Co Ltd inverters

PCS500 (AS4777-2 2020)

500 kW · 3φ

PCS250 (AS4777-2 2020)

250 kW · 3φ

PCS100 (AS4777-2 2020)

100 kW · 3φ

HPS150 (AS4777-2 2020)

150 kW · 1φ

HPS120 (AS4777-2 2020)

120 kW · 1φ

HPS100 (AS4777-2 2020)

100 kW · 1φ

View all Shenzhen Atess Power Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?