Solar inverter · Redx · CEC approved February 2025
CEC listing: RX-7010Plus (AS4777-2 2020)
A 7 kW single-phase solar inverter that is listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Redx RX-7010Plus, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 7 kW |
| Maximum power | 8 kW |
| Apparent power | 7 kVA |
| Phases | 1 |
| Efficiency | |
| Max efficiency | 96% |
| European efficiency | 97% |
| CEC-weighted efficiency | 97% |
| DC input & MPPT | |
| MPPT trackers | 3 |
| Max input voltage | 550 V |
| MPPT voltage min | 120 V |
| MPPT voltage max | 500 V |
| Max input current | 16 A |
| Battery & backup | |
| Battery compatible | Yes |
| Backup capable | Yes |
| Continuous backup | 7 kW |
| Physical | |
| Dimensions (H×W×D) | 1290 × 750 × 210 mm |
| Weight | 35 kg |
| IP rating | IP65 |
| Cooling | Natural cooling |
| Operating temperature | -20°C to 50°C |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| AC breaker | 70 A |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Redx RX-7010Plus against the closest-power inverters from other brands.
| Specification | Redx RX-7010PlusRedx | Energizer Force 7.0HS+Energizer | Energizer Force 7.0SEnergizer |
|---|---|---|---|
| Rated power? | 7 kW | 7 kW | 7 kW |
| Max efficiency? | 96.0% | Not on file | Not on file |
| MPPT trackers? | 3 | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Solar | Hybrid | Solar |
| Battery ready | No | Yes | No |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
The warranty covers defects in materials and workmanship for 10 years from the purchase date. Exclusions include improper installation, environmental issues, and natural disasters. To make a claim, contact Redx with the product purchase invoice.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 15 of 15. The official install manual is the authoritative source — always confirm before acting.
Grid Short CircuitcriticalCall your installerShort circuit detected at AC input
Load short circuitcriticalCall your installerShort circuit detected at inverter output
Battery over currentwarningCall your installerCharge/discharge current too high
Bus soft start failedwarningCall your installerSoft start process could not complete
DC Bus over-voltagewarningCall your installerInput voltage is too high
DC Bus under-voltagewarningCall your installerThe input is suddenly disconnected
EEPROM read failurewarningCall your installerData retrieval issue
Grid overvoltagewarningCall your installerGrid voltage exceeds allowable range
Grid under voltagewarningCall your installerGrid voltage is too low
Inverter overvoltagewarningCall your installerOutput voltage is out of range
Inverter phase lock failurewarningCall your installerPhase alignment error
Inverter undervoltagewarningCall your installerOutput voltage is too low
Islanding protectionwarningCall your installerDisconnected from grid due to protection
IsoFaultwarningCall your installerEarth Fault Alarm
Relay faultwarningCall your installerRelay malfunction detected
RX-7000HY (AS4777-2 2020)
7 kW · 1φ
RX-7013Plus (AS4777-2 2020)
7 kW · 1φ
RX-5000AC (AS4777-2 2020)
5 kW · 1φ
RX-5000HY (AS4777-2 2020)
5 kW · 1φ
RX-5006Plus (AS4777-2 2020)
5 kW · 1φ
RX-5010Plus (AS4777-2 2020)
5 kW · 1φ
Other CEC-approved products from Redx available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.