Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Redx
  4. RX-5010Plus

Solar inverter · Redx · CEC approved February 2025

Redx RX-5010Plus

CEC listing: RX-5010Plus (AS4777-2 2020)

A 5 kW single-phase solar inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

RX-5010Plus: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
10yr
How long Redx Technology Australia Pty Ltd stands behind it

Full datasheet

Every figure on file for the Redx RX-5010Plus, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Efficiency
Max efficiency98%
Physical
Weight107 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
AC breaker70 A

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
3 Feb 2025
Approval expiry
31 Dec 2027
Status
Active
Listed for STCs
Yes

About Redx

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
17
CEC-approved batteries
11
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Redx RX-5010Plus against the closest-power inverters from other brands.

Specification
Redx RX-5010PlusRedx
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Redx RX-5010Plus

The warranty covers the Redx RX-5000Plus series for 10 years, ensuring reliable performance. Important exclusions include non-accredited installation and modifications, and claims can be made through Australian-based support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation or modification voids the warranty.
Environment limits
/
Read the official warranty document (PDF)

Fault & error codes — Redx RX-5010Plus

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • Inverter undervoltagecriticalCall your installer
    Manual (PDF)

    Inverter undervoltage

    What to do
    Check battery voltage; if the alarm persists, contact installation partner.
  • Output overloadcriticalCall your installer
    Manual (PDF)

    Overloaded outputs

    Likely cause
    Excess load connected to the output.
    What to do
    Remove some loads to ensure they are below maximum output; restart the inverter.
  • Battery under voltage or over voltagewarningCall your installer
    Manual (PDF)

    Battery voltage is abnormal

    Likely cause
    Internal circuit protection is triggered due to incorrect battery connection or voltage.
    What to do
    Check battery connections and voltage; restart if necessary; if error message remains, contact installation partner.
  • DC Bus over-voltagewarningCall your installer
    Manual (PDF)

    DC Bus over-voltage

    Likely cause
    Rapid change of power grid voltage may cause high energy input to the inverter.
    What to do
    After the fault error is recovered, the inverter automatically restores to the normal working state; if the fault remains, contact installation partner.
  • DC Bus under-voltagewarningCall your installer
    Manual (PDF)

    DC Bus under-voltage

    Likely cause
    The input is suddenly disconnected.
    What to do
    After the fault is recovered, the inverter will automatically return to normal working state; if the alarm remains after the system is restarted, contact installation partner.
  • Grid over frequencywarningCall your installer
    Manual (PDF)

    Grid frequency too high

    What to do
    Check the grid frequency; if above limits, report to the power grid company; if normal, contact installation partner.
  • Grid overvoltagewarningCall your installer
    Manual (PDF)

    Grid voltage too high

    What to do
    Check the grid voltage or frequency; if it exceeds safe limits, report to the power grid company; if normal, contact installation partner.
  • Grid under frequencywarningCall your installer
    Manual (PDF)

    Grid frequency too low

    What to do
    Check the grid frequency; if below limits, report to the power grid company; if normal, contact installation partner.
  • Grid under voltagewarningCall your installer
    Manual (PDF)

    Grid voltage too low

    What to do
    Check the grid voltage; if it is below allowable limits, report to the power grid company; if normal, contact installation partner.
  • Inverter overvoltagewarningCall your installer
    Manual (PDF)

    Output voltage out of range

    Likely cause
    External load exceeds the specification range of the inverter.
    What to do
    Check external load and ensure it is within specification; after recovery, the inverter automatically returns to normal state; if repeated, contact installation partner.
  • IsoFaultwarningCall your installer
    Manual (PDF)

    Earth Fault Alarm

    Likely cause
    The PV panel is installed abnormally or the insulation resistance is low.
    What to do
    Check whether the PV panel is installed correctly and inspect the PV insulation resistance to the ground.

More Redx Technology Australia Pty Ltd inverters

RX-5000AC (AS4777-2 2020)

5 kW · 1φ

RX-5000HY (AS4777-2 2020)

5 kW · 1φ

RX-5006Plus (AS4777-2 2020)

5 kW · 1φ

RX-5013Plus (AS4777-2 2020)

5 kW · 1φ

RX-7006Plus (AS4777-2 2020)

5 kW · 1φ

RX-7000HY (AS4777-2 2020)

7 kW · 1φ

View all Redx Technology Australia Pty Ltd inverters

More from Redx

Other CEC-approved products from Redx available in Australia.

Redx Batteries

RX-0050

4.608 kWh

RX-0050B

5.12 kWh · LFP

RX-196k (AS4777-2 2020)

196 kWh · LFP

RX-2505AC (AS4777-2 2020)

4.8 kWh

RX-2505PW (AS4777-2 2020)

4.8 kWh

RX-5006Plus (AS4777-2 2020)

6.69 kWh · LFP

View all Redx batteries
View full Redx manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?