Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Qingdao Nahui Energy Technology
  4. N1PH-1N6K

Hybrid inverter · Qingdao Nahui Energy Technology · CEC approved February 2025

Qingdao Nahui Energy Technology N1PH-1N6K

CEC listing: N1PH-1N6K (AS4777-2 2020)

A 6 kW single-phase hybrid inverter that is battery-ready.

Rated power
6kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

N1PH-1N6K: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6kW
How much solar it can turn into usable power at once
Max efficiency
97.5%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Qingdao Nahui Energy Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Qingdao Nahui Energy Technology N1PH-1N6K, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power6 kW
Maximum power6 kW
Apparent power6 kVA
Phases1
Efficiency
Max efficiency97.5%
European efficiency97.2%
CEC-weighted efficiency99.9%
DC input & MPPT
MPPT trackers2
Max input voltage600 V
MPPT voltage min120 V
MPPT voltage max550 V
Max input current26.1 A
Battery & backup
Battery compatibleYes
Backup capableYes
Continuous backup6 kW
Physical
Dimensions (H×W×D)412 × 520 × 172 mm
Weight20 kg
IP ratingIP65
CoolingNatural Convection
Operating temperature-30°C to 60°C
Installation requirements
AC breaker25 A
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
25 Feb 2025
Approval expiry
25 Feb 2028
Status
Active
Listed for STCs
Yes

About Qingdao Nahui Energy Technology

Years on the CEC list
2 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
8
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
25.5 kWh
Annual yield
9,308 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

2 years on the CEC list

How it compares

The Qingdao Nahui Energy Technology N1PH-1N6K against the closest-power inverters from other brands.

Specification
Qingdao Nahui Energy Technology N1PH-1N6KQingdao Nahui Energy Technology
Energizer FORCE 6.0HSEnergizer
Energizer Force 6.0HT+Energizer
Rated power?6 kW6 kW6 kW
Max efficiency?97.5%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and installation guide and user manualPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Qingdao Nahui Energy Technology N1PH-1N6K

This warranty covers the hardware costs for GE-branded solar inverters for 5 years. Exclusions include improper installations and damage from environmental conditions. To make a claim, contact your local distributor or installer with the necessary information.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Faulty installations, modifications by third parties, normal wear and tear, and failure to report problems within one month of occurrence.
Environment limits
Faults or damage caused by exposure to seacoasts/saltwater or other aggressive atmospheres without the Manufacturer's written approval prior to installation.
Read the official warranty document (PDF)

Fault & error codes — Qingdao Nahui Energy Technology N1PH-1N6K

From the install manual

45 documented

Showing 45 of 45. The official install manual is the authoritative source — always confirm before acting.

  • Bat Volt FaultcriticalCall your installer
    Manual (PDF)

    Battery voltage fault.

    Likely cause
    Battery input voltage is out of the expected range.
    What to do
    Check if the battery input voltage is within the normal range.
  • BatConDir FaultcriticalCall your installer
    Manual (PDF)

    The battery connection is reversed.

    Likely cause
    Incorrect battery wiring.
    What to do
    Check if the positive pole and negative pole of battery are correctly connected.
  • BMS Relay FaultcriticalCall your installer
    Manual (PDF)

    The battery relay is fault.

    Likely cause
    Failure in relay control.
    What to do
    Disconnect battery, then reconnect.
  • Bus Volt FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by hardware.

    Likely cause
    Issues within the inverter's internal voltage level.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • ByPassRelayFaultcriticalCall your installer
    Manual (PDF)

    Bypass relay fault.

    Likely cause
    Failure in relay functioning.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • DCI OCP FaultcriticalCall your installer
    Manual (PDF)

    DC component is out of limit in output current.

    Likely cause
    Excessive output current from the inverter.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • DCV OVP FaultcriticalCall your installer
    Manual (PDF)

    DC component is out of limit in output voltage.

    Likely cause
    Excessive output voltage from the inverter.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • EPS Relay FaultcriticalCall your installer
    Manual (PDF)

    The EPS relay always keeps open.

    Likely cause
    Failure in relay control.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • Grid Relay FaultcriticalCall your installer
    Manual (PDF)

    The grid relay always keeps close.

    Likely cause
    Failure in relay control.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • HW Protect FaultcriticalCall your installer
    Manual (PDF)

    Inverter over current or battery over current or PV over current detected by hardware.

    Likely cause
    Overcurrent situation due to various reasons.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • Iso Check FaultcriticalCall your installer
    Manual (PDF)

    The isolation is failed.

    Likely cause
    Failure in insulation monitoring system.
    What to do
    Please check if the insulation of electric wires is damaged.
  • RC OCP FaultcriticalCall your installer
    Manual (PDF)

    The residual current is high.

    Likely cause
    Potential leakage or insulation failure.
    What to do
    Please check if the insulation of electric wires is damaged.
  • SW OCP FaultcriticalCall your installer
    Manual (PDF)

    Output current high detected by software.

    Likely cause
    Software monitoring detected high current output.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • AC HCT FaultwarningCall your installer
    Manual (PDF)

    AC Current Sensor Fault.

    Likely cause
    Issue with the current sensor readings.
    What to do
    Disconnect solar power PV+, PV- and battery, reconnect them.
  • AD Sample FaultwarningCall your installer
    Manual (PDF)

    The sample value between master and slave is not consistent.

    Likely cause
    Communication error between components.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • Bat Low Faultwarning
    Manual (PDF)

    The battery power is low.

    Likely cause
    Insufficient charge in the battery.
    What to do
    Wait for the battery to be recharged.
  • BMS Cell FaultwarningCall your installer
    Manual (PDF)

    Battery cell error.

    Likely cause
    Issue with battery cells within the battery pack.
    What to do
    Wait for 5 minutes, check again.
  • BMS Dcov FaultwarningCall your installer
    Manual (PDF)

    Battery input over voltage error.

    Likely cause
    Excess voltage supplied to the battery input.
    What to do
    Wait for 5 minutes, check again.
  • BMS IN_COM FaultwarningCall your installer
    Manual (PDF)

    BMS internal communication fault.

    Likely cause
    Communication issues within the BMS system.
    What to do
    Disconnect battery, check wiring between inverter and battery, battery internal wiring then reconnect.
  • BMS Other FaultwarningCall your installer
    Manual (PDF)

    Battery other error.

    Likely cause
    General failure in battery system.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect ChrOCwarningCall your installer
    Manual (PDF)

    Battery over current charging protect.

    Likely cause
    Excess current detected during charging.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect DischargeOCwarningCall your installer
    Manual (PDF)

    Battery over current discharging protect.

    Likely cause
    Excess current detected during discharging.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect LVwarningCall your installer
    Manual (PDF)

    Battery under voltage protect.

    Likely cause
    Insufficient voltage detected.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect OVwarningCall your installer
    Manual (PDF)

    Battery over voltage protect.

    Likely cause
    Excess voltage detected.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect TemHighwarningCall your installer
    Manual (PDF)

    Battery temperature is high.

    Likely cause
    Excessive heat detected within the battery system.
    What to do
    Wait for 5 minutes, check again.
  • BMS Protect TemLowwarningCall your installer
    Manual (PDF)

    Battery temperature is low.

    Likely cause
    Insufficient heat detected within the battery system.
    What to do
    Wait for 5 minutes, check again.
  • BMS RV FaultwarningCall your installer
    Manual (PDF)

    Battery input transposition error.

    Likely cause
    Incorrect battery connection reversing polarity.
    What to do
    Wait for 5 minutes, check again.
  • BMS Tepr FaultwarningCall your installer
    Manual (PDF)

    Battery temperature sensor error.

    Likely cause
    Incorrect temperature readings from the battery.
    What to do
    Wait for 5 minutes, check again.
  • BMS Volt FaultwarningCall your installer
    Manual (PDF)

    Battery voltage sensor error.

    Likely cause
    Incorrect voltage readings from the battery.
    What to do
    Wait for 5 minutes, check again.
  • BMS_LostwarningCall your installer
    Manual (PDF)

    The communication between BMS and Inverter is interrupted.

    Likely cause
    Improper connection of BMS to inverter.
    What to do
    Check if the communication cable between BMS and Inverter is correctly and well connected.
  • Dsp Lost FaultwarningCall your installer
    Manual (PDF)

    SCI communication fault.

    Likely cause
    Issue with the communication interface.
    What to do
    Disconnect solar power PV+, PV- and battery, reconnect them.
  • EPS Over Loadwarning
    Manual (PDF)

    Over load in off grid mode.

    Likely cause
    Equipment connected exceeds the inverter's load capacity.
    What to do
    Please check if the eps load power exceeds the limit.
  • GFCI HW FaultwarningCall your installer
    Manual (PDF)

    The residual current circuit is fault.

    Likely cause
    Potential leakage or circuit breaker failure.
    What to do
    Please check if the insulation of electric wires is damaged.
  • Grid Freq Faultwarning
    Manual (PDF)

    Grid frequency out of range.

    Likely cause
    Issues with the grid frequency provided by the utility.
    What to do
    System will reconnect if the utility is back to normal.
  • Grid Lost Faultwarning
    Manual (PDF)

    Grid is lost.

    Likely cause
    Utility power failure.
    What to do
    System will reconnect if the utility is back to normal.
  • Grid Volt Faultwarning
    Manual (PDF)

    Grid voltage out of range.

    Likely cause
    Fluctuations or issues in the utility voltage.
    What to do
    System will reconnect if the utility is back to normal.
  • Inter Fan FaultwarningCall your installer
    Manual (PDF)

    Fan Device Fault.

    Likely cause
    Fan malfunction or obstruction.
    What to do
    Disconnect solar power PV+, PV- and battery, reconnect them and check the fan.
  • Inv EEPROM FaultwarningCall your installer
    Manual (PDF)

    The master eeprom is fault.

    Likely cause
    Failure in EEPROM functionality.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • Meter Lost FaultwarningCall your installer
    Manual (PDF)

    The communication between meter and Inverter is interrupted.

    Likely cause
    Improper connection of the meter to inverter.
    What to do
    Check if the communication cable between meter and Inverter is correctly and well connected.
  • Mgr EEPROM FaultwarningCall your installer
    Manual (PDF)

    The manager eeprom is fault.

    Likely cause
    Failure in EEPROM functionality.
    What to do
    Disconnect PV, grid and battery, then reconnect.
  • Other Dev FaultwarningCall your installer
    Manual (PDF)

    Other device fault.

    Likely cause
    General malfunction of components.
    What to do
    Turn off the PV, battery and grid, reconnect them.
  • PV Volt FaultwarningCall your installer
    Manual (PDF)

    PV voltage out of range.

    Likely cause
    Output voltage of the PV panels is too high or too low.
    What to do
    Please check the output voltage of PV panels.
  • SPI CommFaultwarningCall your installer
    Manual (PDF)

    The communication between master and slave fault.

    Likely cause
    Communication issues in the inverter's internal system.
    What to do
    Disconnect solar power PV+, PV- and battery, reconnect them.
  • Temp Over Faultwarning
    Manual (PDF)

    The inverter temperature is high.

    Likely cause
    Inadequate ventilation or excessive load.
    What to do
    Check if the environment temperature is suitable.
  • Vgrid 10M Faultwarning
    Manual (PDF)

    The grid voltage is out of range for the last 10 minutes.

    Likely cause
    Continuous fluctuation of grid voltage.
    What to do
    System will reconnect if the utility is back to normal.

More Qingdao Nahui Energy Technology Co Ltd inverters

N1PH-1N5K (AS4777-2 2020)

5 kW · 1φ

N1PH-1N3.6K (AS4777-2 2020)

3.68 kW · 1φ

N1PH-1N3K (AS4777-2 2020)

3 kW · 1φ

HH3P-6KA1/HU (AS4777-2 2020)

6 kW · 3φ

HH3P-5KA1/HU (AS4777-2 2020)

5 kW · 3φ

HH3P-8KA1/HU (AS4777-2 2020)

8 kW · 3φ

View all Qingdao Nahui Energy Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?