Hybrid inverter · Qingdao Nahui Energy Technology · N1PH series · CEC approved February 2025
CEC listing: N1PH-1N3K (AS4777-2 2020)
A 3 kW single-phase hybrid inverter that is battery-ready.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Rated power
How much solar it can turn into usable power at once
Max efficiency
How much of the solar you make reaches the house
Phases
Runs on a standard single-phase supply
MPPT trackers
2 roof faces can be tuned independently
Type
Runs solar and a battery from one unit
Warranty
How long Qingdao Nahui Energy Technology Co Ltd stands behind it
Every figure on file for the Qingdao Nahui Energy Technology N1PH-1N3K, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 3 kW |
| Maximum power | 3 kW |
| Apparent power | 3 kVA |
| Phases | 1 |
| Efficiency | |
| Max efficiency | 97.42% |
| European efficiency | 97.15% |
| CEC-weighted efficiency | 99.9% |
| DC input & MPPT | |
| MPPT trackers | 2 |
| Max input voltage | 600 V |
| MPPT voltage min | 120 V |
| MPPT voltage max | 550 V |
| Max input current | 13.5 A |
| Battery & backup | |
| Battery compatible | Yes |
| Backup capable | Yes |
| Continuous backup | 3 kW |
| Physical | |
| Dimensions (H×W×D) | 412 × 520 × 172 mm |
| Weight | 20 kg |
| IP rating | IP65 |
| Cooling | Natural Convection |
| Operating temperature | -30°C to 60°C |
| Installation requirements | |
| AC breaker | 25 A |
| Cable gauge | 4 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Battery compatible
Yes
Backup capable
Yes
CEC approved
25 Feb 2025
Approval expiry
25 Feb 2028
Status
Active
Eligible for rebates
Yes
Years in AU Market
2 years
Australian Office
Not verified
CEC-Approved Batteries
0
CEC-Approved Panels
0
Category
Unknown
Typical installed, inverter only
$1,050–$1,800
Prices vary by installer, configuration and site complexity. Get exact quotes from installers you choose.
Compare quotes from installers you choose
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead — ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Qingdao Nahui Energy Technology N1PH-1N3K against the closest-power inverters from other brands.
| Specification | Qingdao Nahui Energy Technology N1PH-1N3KQingdao Nahui Energy Technology | Energizer FORCE 3.0HSEnergizer | Energizer Force 3SEnergizer |
|---|---|---|---|
| Rated power? | 3 kW | 3 kW | 3 kW |
| Max efficiency? | 97.4%best value | 0.0% | 0.0% |
| MPPT trackers? | 2 | Not verified | Not verified |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Hybrid | Hybrid | Solar |
| Battery ready | Yes | Yes | No |
| Warranty | 5 years | Not verified | Not verified |
Specs from the CEC register and datasheet enrichment. Indicative — confirm exact figures with your installer.
This warranty covers the hardware costs for GE-branded solar inverters for 5 years. Exclusions include improper installations and damage from environmental conditions. To make a claim, contact your local distributor or installer with the necessary information.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 45 of 45. The official install manual is the authoritative source — always confirm before acting.
Bat Volt FaultcriticalCall your installerBattery voltage fault.
BatConDir FaultcriticalCall your installerThe battery connection is reversed.
BMS Relay FaultcriticalCall your installerThe battery relay is fault.
Bus Volt FaultcriticalCall your installerBus voltage out of range detected by hardware.
ByPassRelayFaultcriticalCall your installerBypass relay fault.
DCI OCP FaultcriticalCall your installerDC component is out of limit in output current.
DCV OVP FaultcriticalCall your installerDC component is out of limit in output voltage.
EPS Relay FaultcriticalCall your installerThe EPS relay always keeps open.
Grid Relay FaultcriticalCall your installerThe grid relay always keeps close.
HW Protect FaultcriticalCall your installerInverter over current or battery over current or PV over current detected by hardware.
Iso Check FaultcriticalCall your installerThe isolation is failed.
RC OCP FaultcriticalCall your installerThe residual current is high.
SW OCP FaultcriticalCall your installerOutput current high detected by software.
AC HCT FaultwarningCall your installerAC Current Sensor Fault.
AD Sample FaultwarningCall your installerThe sample value between master and slave is not consistent.
Bat Low FaultwarningThe battery power is low.
BMS Cell FaultwarningCall your installerBattery cell error.
BMS Dcov FaultwarningCall your installerBattery input over voltage error.
BMS IN_COM FaultwarningCall your installerBMS internal communication fault.
BMS Other FaultwarningCall your installerBattery other error.
BMS Protect ChrOCwarningCall your installerBattery over current charging protect.
BMS Protect DischargeOCwarningCall your installerBattery over current discharging protect.
BMS Protect LVwarningCall your installerBattery under voltage protect.
BMS Protect OVwarningCall your installerBattery over voltage protect.
BMS Protect TemHighwarningCall your installerBattery temperature is high.
BMS Protect TemLowwarningCall your installerBattery temperature is low.
BMS RV FaultwarningCall your installerBattery input transposition error.
BMS Tepr FaultwarningCall your installerBattery temperature sensor error.
BMS Volt FaultwarningCall your installerBattery voltage sensor error.
BMS_LostwarningCall your installerThe communication between BMS and Inverter is interrupted.
Dsp Lost FaultwarningCall your installerSCI communication fault.
EPS Over LoadwarningOver load in off grid mode.
GFCI HW FaultwarningCall your installerThe residual current circuit is fault.
Grid Freq FaultwarningGrid frequency out of range.
Grid Lost FaultwarningGrid is lost.
Grid Volt FaultwarningGrid voltage out of range.
Inter Fan FaultwarningCall your installerFan Device Fault.
Inv EEPROM FaultwarningCall your installerThe master eeprom is fault.
Meter Lost FaultwarningCall your installerThe communication between meter and Inverter is interrupted.
Mgr EEPROM FaultwarningCall your installerThe manager eeprom is fault.
Other Dev FaultwarningCall your installerOther device fault.
PV Volt FaultwarningCall your installerPV voltage out of range.
SPI CommFaultwarningCall your installerThe communication between master and slave fault.
Temp Over FaultwarningThe inverter temperature is high.
Vgrid 10M FaultwarningThe grid voltage is out of range for the last 10 minutes.
Part of the Qingdao Nahui Energy Technology N1PH series
Compare every Qingdao Nahui Energy Technology N1PH variant side by side →
HH3P-10KA1/HU (AS4777-2 2020)
10 kW · 3φ
HH3P-5KA1/HU (AS4777-2 2020)
5 kW · 3φ
HH3P-6KA1/HU (AS4777-2 2020)
6 kW · 3φ
HH3P-8KA1/HU (AS4777-2 2020)
8 kW · 3φ
N1PH-1N3.6K (AS4777-2 2020)
3.68 kW · 1φ
N1PH-1N5K (AS4777-2 2020)
5 kW · 1φ
Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.