Hybrid inverter · Deye · CEC approved November 2026
Deye SUN-8K-SG02LP1-AU-AM2-P
CEC listing: SUN-8K-SG02LP1-AU-AM2-P (AS4777-2 2020)
An 8 kW single-phase hybrid inverter that is battery-ready.
- Rated power
- 8kW
- How much solar it can run at once
- Battery-ready
- Yes
- A battery plugs straight in
- Feed-in credits (DEBS)
- No
- DEBS pays for exports only when the inverter is 5 kW or less
Key specs, in plain terms
The numbers that matter for a home. The full datasheet is below.
- Rated power
- 8kW
- How much solar it can turn into usable power at once
- Max efficiency
- 97.6%
- How much of the solar you make reaches the house
- Phases
- Single
- Runs on a standard single-phase supply
- Type
- Hybrid
- Runs solar and a battery from one unit
- Warranty
- 10yr
- How long NingBo Deye Inverter Technology Co Ltd stands behind it
What we can tell you
Read from the figures on this page. No review written yet.
- It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
- It runs on a standard single-phase supply.
- It is CEC-approved, which a new install needs to qualify for STCs.
Features and CEC approval
- Battery compatible
- Yes
- Backup capable
- Yes
- CEC approved
- 20 Nov 2026
- Approval expiry
- 7 Nov 2029
- Status
- Active
- Listed for STCs
- Yes
About Deye
- Years on the CEC list
- 6 years
- Australian office
- Not verified
- Category
- Mid-Tier
- CEC-approved inverters
- 94
- CEC-approved batteries
- 53
Documents
WA compliance
- Remote management
- No record
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.
Website
au.deyeinverter.comPerth performance
Estimate for a full-size array on this inverter
- Daily yield
- 34.0 kWh
- Annual yield
- 12,410 kWh
At 5 peak sun hours a day (BOM) with a 15% system derate.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Full datasheet
Every figure on file for the Deye SUN-8K-SG02LP1-AU-AM2-P, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 97.6% |
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| Top clearance | 420 mm |
| Side clearance | 233 mm |
| AC breaker | 52.2 A |
| Cable gauge | 10 mm² |
| Earthing method | L+N+PE |
| DNSP pre-approval | No |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
How it compares
The Deye SUN-8K-SG02LP1-AU-AM2-P against the closest-power inverters from other brands.
| Specification | Energizer Force 8.0HS+Energizer | Energizer Force 8.0HT+Energizer | |
|---|---|---|---|
| Rated power? | 8 kW | 8 kW | 8 kW |
| Max efficiency? | 97.6% | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
10-year inverter warranty
Deye SUN-8K-SG02LP1-AU-AM2-PThis warranty covers defects for 10 years. Excludes damages from improper installation. Claims can be made with the serial number and purchase receipt.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
- Coverage shape
- Full-replacement coverage
- If you sell the home
- Does not transfer with the home
- What voids it
- Non-accredited installation, modification, tampering, incorrect installation, force majeure.
- Environment limits
- None specified.
Fault & error codes — Deye SUN-8K-SG02LP1-AU-AM2-P
From the install manual
Showing 25 of 25. The official install manual is the authoritative source — always confirm before acting.
- Manual (PDF)
F01criticalCall your installerDC input polarity reverse fault
- Likely cause
- 1. Check the PV input polarity
- What to do
- Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F07criticalCall your installerDC_START_Failure
- Likely cause
- 1. The BUS voltage can be built from PV or battery
- What to do
- Restart the inverter, if the fault still exists, please contact us for help.
- Manual (PDF)
F15criticalCall your installerAC over current fault of software
- Likely cause
- AC side over current fault
- What to do
- 1. Please check whether the backup load power and common load power are within the range; 2. Restart and check whether it is normal; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F16criticalCall your installerAC leakage current fault
- Likely cause
- Leakage current fault
- What to do
- 1. Check the PV side cable ground connection 2. Restart the system 2-3 times 3. if the fault still exists, please contact us for help.
- Manual (PDF)
F18criticalCall your installerAC over current fault of hardware
- Likely cause
- AC side over current fault
- What to do
- 1. Please check whether the backup load power and common load power are within the range; 2. Restart and check whether it is normal; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F20criticalCall your installerDC over current fault of the hardware
- Likely cause
- DC side over current fault
- What to do
- 1. Check PV module connect and battery connect; 2. When in the off-grid mode, the inverter startup with big power load, it may report F20. Please reduce the load power connected; 3. Turn off the DC switch and AC switch and then wait one minute, then turn on the DC/AC switch again; 4. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F21criticalCall your installerTz_HV_Overcurr_fault
- Likely cause
- BUS over current.
- What to do
- 1. Check the PV input current and battery current setting 2. Restart the system 2-3 times. 3. If the fault still exists, please contact us for help.
- Manual (PDF)
F23criticalCall your installerTz_GFCI_OC_current is transient over current
- Likely cause
- Leakage current fault
- What to do
- 1. Check PV side cable ground connection. 2. Restart the system 2-3 times. 3. If the fault still exists, please contact us for help.
- Manual (PDF)
F24criticalCall your installerDC insulation failure
- Likely cause
- PV isolation resistance is too low
- What to do
- 1. Check the connection of PV panels and inverter is firmly and correctly; 2. Check whether the PE cable of inverter is connected to ground; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F34criticalCall your installerAC Overcurrent fault
- Likely cause
- 1. Check the backup load connected, make sure it is in allowed power range; 2. If the fault still exists, please contact us for help.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F46criticalCall your installerbackup battery fault
- Likely cause
- 1. Please check each battery status, such as voltage/SOC and parameters etc., and make sure all the parameters are the same.
- What to do
- 2. If the fault still exists, please contact us for help.
- Manual (PDF)
F55criticalCall your installerDC busbar voltage is too high
- Likely cause
- BUS voltage is too high
- What to do
- 1. Check whether battery voltage is too high; 2. Check the PV input voltage, make sure it is within the allowed range; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F56criticalCall your installerDC busbar voltage is too low
- Likely cause
- Battery voltage low
- What to do
- 1. Check whether battery voltage is too low; 2. If the battery voltage is too low, using PV or grid to charge the battery; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F58criticalCall your installerBMS communication fault
- Likely cause
- 1. it tells the communication between hybrid inverter and battery BMS disconnected when 'BMS_Err-Stop' is active; 2. If don't want to see this happen, you can disable 'BMS_Err-Stop' item on the LCD; 3. If the fault still exists, please contact us for help.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F63criticalCall your installerARC fault
- Likely cause
- 1. ARC fault detection is only for the US market; 2. Check PV module cable connection and clear the fault; 3. Seek help from us, if cannot go back to normal state.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F64criticalCall your installerHeat sink high temperature failure
- Likely cause
- Heat sink temperature is too high
- What to do
- 1. Check whether the work environment temperature is too high; 2. Turn off the inverter for 10 mins and restart; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F13warningworking mode change
- Likely cause
- 1. When the grid type and frequency changed it will report F13; 2. When the battery mode was changed to 'No battery' mode, it will report F13; 3. For some old FW versions, it will report F13 when the system work mode changed; 4. Generally, it will disappear automatically when shows F13; 5. If still same, and turn off the DC switch and AC switch and wait for one minute and then turn on the DC/AC switch; 6. Seek help from us, if cannot go back to normal state.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F26warningThe DC busbar is unbalanced
- Likely cause
- 1. Please wait for a while and check whether it is normal; 2. When the load power of 3 phases is big different, it will report the F26; 3. When there's DC leakage current, it will report F26; 4. Restart the system 2-3 times; 5. Seek help from us, if cannot go back to normal state.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F29warningParallel CAN Bus fault
- Likely cause
- 1. When in parallel mode, check the parallel communication cable connection and hybrid inverter communication address setting; 2. During the parallel system startup period, inverters will report F29. But when all inverters are in ON status, it will disappear automatically; 3. If the fault still exists, please contact us for help.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F41warningParallel system stop
- Likely cause
- 1. Check the hybrid inverter work status. If there's 1pcs hybrid inverter shutdown, all hybrid inverters will report F41 fault; 2. If the fault still exists, please contact us for help.
- What to do
- Follow the troubleshooting steps.
- Manual (PDF)
F42warningCall your installerAC line low voltage
- Likely cause
- Grid voltage fault
- What to do
- Check the AC voltage is in the range of standard voltage specification; 2. Check whether grid AC cables are firmly and correctly connected; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F47warningCall your installerAC over frequency
- Likely cause
- Grid frequency out of range
- What to do
- 1. Check the frequency is in the range of specification or not; 2. Check whether AC cables are firmly and correctly connected; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F48warningCall your installerAC lower frequency
- Likely cause
- Grid frequency out of range
- What to do
- 1. Check the frequency is in the range of specification or not; 2. Check whether AC cables are firmly and correctly connected; 3. Seek help from us, if cannot go back to normal state.
- Manual (PDF)
F22infoTz_EmergStop_Fault
- Likely cause
- Remotely shutdown
- What to do
- It tells the inverter is remotely controlled.
- Manual (PDF)
F62infoDRMs0_stop
- Likely cause
- 1. the DRM function is for the Australia market only; 2. Check the DRM function is active or not; 3. Seek help from us, if cannot go back to normal state after restarting the system.
- What to do
- Follow the troubleshooting steps.
More Deye inverters
AI-W5.1-8P1-AU-B (AS4777-2 2020)
8 kW · 1φ
Al-W5.1-8P1-AU-B (AS4777-2 2020)
8 kW · 1φ
SUN-8K-G02P1-AU-AM2 (AS4777-2 2020)
8 kW · 1φ
SUN-8K-SG02LP1-AU-AM2 (AS4777-2 2020)
8 kW · 1φ
SUN-8K-SG05LP1-AU-AM2-P (AS4777-2 2020)
8 kW · 1φ
SUN-8K-SG05LP1-AU (AS4777-2 2020)
8 kW · 1φ
More from Deye
Other CEC-approved products from Deye available in Australia.
Want to take the next step?
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.