Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Deye
  4. SUN-20K-SG05LP3-AU-SM2

Hybrid inverter · Deye · CEC approved April 2026

Deye SUN-20K-SG05LP3-AU-SM2

CEC listing: SUN-20K-SG05LP3-AU-SM2 (AS4777-2 2020)

A 20 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
20kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SUN-20K-SG05LP3-AU-SM2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
20kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long NingBo Deye Inverter Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Deye SUN-20K-SG05LP3-AU-SM2, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.6%
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance500 mm
Side clearance500 mm
AC breaker100 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
20 Apr 2026
Approval expiry
20 Apr 2029
Status
Active
Listed for STCs
Yes

About Deye

Years on the CEC list
6 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
90
CEC-approved batteries
53
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Website

au.deyeinverter.com
6 years on the CEC list

How it compares

The Deye SUN-20K-SG05LP3-AU-SM2 against the closest-power inverters from other brands.

Specification
Deye SUN-20K-SG05LP3-AU-SM2Deye
Afore AF20K-THAfore
Solplanet ASW020K-THSolplanet
Rated power?20 kW20 kW20 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Deye SUN-20K-SG05LP3-AU-SM2

This solar inverter has a warranty of up to 10 years, covering defects in materials and workmanship. It excludes issues from non-accredited installations, and claims can be made by contacting support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modification, or tampering voids warranty.
Environment limits
-40 to +60°C; temperatures above 45°C may cause derating.
Read the official warranty document (PDF)

Fault & error codes — Deye SUN-20K-SG05LP3-AU-SM2

From the install manual

25 documented

Showing 25 of 25. The official install manual is the authoritative source — always confirm before acting.

  • F01criticalCall your installer
    Manual (PDF)

    DC input polarity reverse fault

    Likely cause
    Check the PV input polarity.
    What to do
    Seek help from us if cannot go back to normal state.
  • F07criticalCall your installer
    Manual (PDF)

    DC_START_Failure

    Likely cause
    The BUS voltage cannot be built from PV or battery.
    What to do
    Restart the inverter. If the fault still exists, please contact us for help.
  • F15criticalCall your installer
    Manual (PDF)

    AC over current fault of software

    Likely cause
    AC side over current fault.
    What to do
    Check whether the backup load power and common load power are within the range; restart and check whether it is normal.
  • F16criticalCall your installer
    Manual (PDF)

    AC leakage current fault

    Likely cause
    Leakage current fault.
    What to do
    Check the PV side cable ground connection; restart the system 2-3 times.
  • F18criticalCall your installer
    Manual (PDF)

    AC over current fault of hardware

    Likely cause
    AC side over current fault.
    What to do
    Check whether the backup load power and common load power are within the range; restart and check whether it is normal.
  • F20criticalCall your installer
    Manual (PDF)

    DC over current fault of the hardware

    Likely cause
    DC side over current fault.
    What to do
    Check PV module connection and battery connection; reduce the load power connected if necessary.
  • F21criticalCall your installer
    Manual (PDF)

    BUS over current

    Likely cause
    Check the PV input current and battery current setting.
    What to do
    Restart the system 2-3 times.
  • F23criticalCall your installer
    Manual (PDF)

    Transient over current fault

    Likely cause
    Leakage current fault.
    What to do
    Check PV side cable ground connection; restart the system.
  • F24criticalCall your installer
    Manual (PDF)

    DC insulation failure

    Likely cause
    PV isolation resistance is too low.
    What to do
    Check PV panel connections and PE cable connections.
  • F34criticalCall your installer
    Manual (PDF)

    AC Overcurrent fault

    Likely cause
    Check the backup load connected.
    What to do
    If the fault still exists, please contact us for help.
  • F46criticalCall your installer
    Manual (PDF)

    Backup battery fault

    Likely cause
    Check each battery status.
    What to do
    If the fault still exists, please contact us for help.
  • F55criticalCall your installer
    Manual (PDF)

    DC busbar voltage is too high

    Likely cause
    Check whether battery voltage is too high.
    What to do
    Seek help from us if cannot go back to normal state.
  • F56criticalCall your installer
    Manual (PDF)

    DC busbar voltage is too low

    Likely cause
    Check whether battery voltage is too low.
    What to do
    Charge the battery using PV or grid, if low.
  • F58criticalCall your installer
    Manual (PDF)

    BMS communication fault

    Likely cause
    Communication between hybrid inverter and battery BMS disconnected.
    What to do
    If the fault still exists, please contact us for help.
  • F64criticalCall your installer
    Manual (PDF)

    Heat sink high temperature failure

    Likely cause
    Work environment temperature is too high.
    What to do
    Turn off the inverter for 10 minutes and restart.
  • F22warning
    Manual (PDF)

    Remotely shutdown

    Likely cause
    Inverter is remotely controlled.
    What to do
    Check communication setup.
  • F26warning
    Manual (PDF)

    DC busbar is unbalanced

    Likely cause
    Load power of 3 phases differs significantly.
    What to do
    Wait for a while and check whether it is normal.
  • F29warningCall your installer
    Manual (PDF)

    Parallel CAN Bus fault

    Likely cause
    Check the parallel communication cable connection.
    What to do
    If the fault still exists, please contact us for help.
  • F41warningCall your installer
    Manual (PDF)

    Parallel system stop

    Likely cause
    Check the hybrid inverter work status.
    What to do
    If the fault still exists, please contact us for help.
  • F42warningCall your installer
    Manual (PDF)

    AC line low voltage

    Likely cause
    Grid voltage fault.
    What to do
    Check the AC voltage and connections.
  • F47warningCall your installer
    Manual (PDF)

    AC over frequency

    Likely cause
    Grid frequency out of range.
    What to do
    Check grid frequency specifications.
  • F48warningCall your installer
    Manual (PDF)

    AC lower frequency

    Likely cause
    Grid frequency out of range.
    What to do
    Check grid frequency specifications.
  • F62warningCall your installer
    Manual (PDF)

    DRM function issue

    Likely cause
    Check the DRM function is active.
    What to do
    If the fault still exists, please contact us for help.
  • F63warningCall your installer
    Manual (PDF)

    ARC fault detection

    Likely cause
    Check PV module cable connection.
    What to do
    Clear the fault.
  • F13info
    Manual (PDF)

    Working mode change

    Likely cause
    Grid type or frequency changed; battery mode changed to 'No battery'.
    What to do
    Generally, it will disappear automatically. If still the same, turn off the DC and AC switch and wait one minute, then turn on the DC/AC switch.

More NingBo Deye Inverter Technology Co Ltd inverters

SUN-20K-G05-AU (AS4777-2 2020)

20 kW · 3φ

SUN-20K-SG01HP3-AU-AM2 (AS4777-2 2020)

20 kW · 3φ

SUN-18K-G05-AU (AS4777-2 2020)

18 kW · 3φ

SUN-18K-SG05LP3-AU-SM2 (AS4777-2 2020)

18 kW · 3φ

SUN-16K-SG05LP3-AU-AM2 (AS4777-2 2020)

16 kW · 3φ

SUN-15K-G05-AU (AS4777-2 2020)

15 kW · 3φ

View all NingBo Deye Inverter Technology Co Ltd inverters

More from Deye

Other CEC-approved products from Deye available in Australia.

Deye Batteries

AI-W10.2-B

10.24 kWh · LFP

AI-W15.3-B

15.36 kWh · LFP

AI-W20.4-B

20.48 kWh · LFP

AI-W25.6-B

25.6 kWh · LFP

AI-W30.7-B

30.72 kWh · LFP

AI-W5.1-B

5.12 kWh · LFP

View all Deye batteries
View full Deye manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?