Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. iStore
  4. IS-HYB-8000-1PH

Hybrid inverter · iStore · CEC approved May 2026

iStore IS-HYB-8000-1PH

CEC listing: IS-HYB-8000-1PH (AS4777-2 2020)

An 8 kW single-phase hybrid inverter that is battery-ready.

Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

IS-HYB-8000-1PH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long iStore (QLD) Pty Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the iStore IS-HYB-8000-1PH, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP65
Installation requirements
Top clearance500 mm
Side clearance500 mm
AC breaker50 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
1 May 2026
Approval expiry
1 May 2029
Status
Active
Listed for STCs
Yes

About iStore

Years on the CEC list
3 years
Australian office
Yes
Category
Budget
CEC-approved inverters
12
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.istore.net.au
3 years on the CEC list

How it compares

The iStore IS-HYB-8000-1PH against the closest-power inverters from other brands.

Specification
iStore IS-HYB-8000-1PHiStore
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

iStore IS-HYB-8000-1PH

This warranty covers parts and labor for 10 years, with a 2-year free extension. Warranty voids if improperly installed or modified. Claims can be made through support channels.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, tampering.
Environment limits
Derating above 45°C, operating temperature range -25 to +60°C.
Read the official warranty document (PDF)

Fault & error codes — iStore IS-HYB-8000-1PH

From the install manual

13 documented

Showing 13 of 13. The official install manual is the authoritative source — always confirm before acting.

  • 2001criticalCall your installer
    Manual (PDF)

    High string input voltage

    Likely cause
    The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the PV string open-circuit voltage exceeds the maximum inverter operating voltage.
    What to do
    Reduce the number of PV modules connected in series to the PV string until the PV string open-circuit voltage is less than or equal to the maximum inverter operating voltage.
  • 2002criticalCall your installer
    Manual (PDF)

    DC Arc Fault

    Likely cause
    The PV string power cables are or are in poor contact.
    What to do
    Check whether the string power cables are in poor contact.
  • 2003criticalCall your installer
    Manual (PDF)

    DC arc fault

    Likely cause
    The PV string power cables arc or are in poor contact.
    What to do
    Check whether the PV string cables arc or are in poor contact.
  • 2011criticalCall your installer
    Manual (PDF)

    String reverse connection

    Likely cause
    The PV string polarity is reversed.
    What to do
    Check whether the PV string is reversely connected to the inverter. If yes, wait until the solar irradiance declines at night and the PV string current drops to below 0.5 A. Then, turn off the DC switch and correct the PV string connection.
  • 2021criticalCall your installer
    Manual (PDF)

    AFCI self-check failure

    Likely cause
    The AFCI self-check fails.
    What to do
    Turn off the AC output switch and DC input switch, and then turn them on after 5 minutes. If the alarm persists, contact your dealer or technical support.
  • 2031criticalCall your installer
    Manual (PDF)

    Phase wire short-circuited to PE

    Likely cause
    The impedance of the output phase wire to PE is low or the output phase wire is short-circuited to PE.
    What to do
    Check the impedance of the output phase wire to PE, locate and rectify the fault.
  • 2032critical
    Manual (PDF)

    Grid loss

    Likely cause
    Power grid outage occurs, or the AC circuit is disconnected or the AC switch is off.
    What to do
    Check whether the AC circuit is disconnected or the AC switch is off; alarm will clear automatically after power grid recovers.
  • 2033criticalCall your installer
    Manual (PDF)

    Grid undervoltage

    Likely cause
    The power grid voltage is below the lower threshold or the low-voltage duration has lasted too long.
    What to do
    Check whether the power grid voltage is within the acceptable range; if not, contact the local power operator.
  • 2034criticalCall your installer
    Manual (PDF)

    Grid overvoltage

    Likely cause
    The power grid voltage exceeds the upper threshold or the high voltage duration has lasted too long.
    What to do
    Check whether the power grid frequency is within the acceptable range; if not, contact the local power operator.
  • 2036criticalCall your installer
    Manual (PDF)

    Grid Overfrequency

    Likely cause
    The actual power grid frequency is higher than the standard requirement for the local power grid.
    What to do
    If the alarm occurs occasionally, the power grid may be abnormal temporarily. The device automatically recovers after detecting that the power grid becomes normal. If the alarm occurs frequently, check whether the power grid frequency is within the allowed range. If no, contact the local power operator. If yes, modify the grid overfrequency protection threshold through the mobile app with the consent of the local power operator.
  • 2037criticalCall your installer
    Manual (PDF)

    Grid Underfrequency

    Likely cause
    The actual power grid frequency is lower than the standard requirement for the local power grid.
    What to do
    If the alarm occurs occasionally, the power grid may be abnormal temporarily. The device automatically recovers after detecting that the power grid becomes normal. If the alarm occurs frequently, check whether the power grid frequency is within the allowed range. If no, contact the local power operator. If yes, modify the grid underfrequency protection threshold through the mobile app with the consent of the local power operator.
  • 2064criticalCall your installer
    Manual (PDF)

    Device Fault

    Likely cause
    A major fault has occurred on the internal circuit of the device.
    What to do
    Contact your vendor or technical support, wait until the PV string current decreases to below 0.5A, and then turn off all DC switches.
  • 2012warning
    Manual (PDF)

    String current backfeed

    Likely cause
    The number of PV modules connected in series to the PV string is insufficient, resulting in the terminal voltage being lower than that of other strings.
    What to do
    Check whether the number of PV modules connected in series to the PV string is less than that of other PV strings and adjust accordingly.

More iStore (QLD) Pty Ltd inverters

IS-HYB-10000-1PH (AS4777-2 2020)

9.999 kW · 1φ

IS-HYB-6000-1PH (AS4777-2 2020)

6 kW · 1φ

IS-HYB-5000-1PH (AS4777-2 2020)

5 kW · 1φ

IS-HYB-5000HC-1PH (AS4777-2 2020)

4.999 kW · 1φ

IS-HYB-10000-3PH (AS4777-2 2020)

9.999 kW · 3φ

IS-HYB-6000-3PH (AS4777-2 2020)

6 kW · 3φ

View all iStore (QLD) Pty Ltd inverters

More from iStore

Other CEC-approved products from iStore available in Australia.

iStore Batteries

IS-BATT-10000-S0

10 kWh · LFP

IS-BATT-14000-S1

13.8 kWh · LFP

IS-BATT-15000-S0

15 kWh · LFP

IS-BATT-21000-S1

20.7 kWh · LFP

IS-BATT-5000-S0

5 kWh · LFP

IS-BATT-7000-S1

6.9 kWh · LFP

View all iStore batteries
View full iStore manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?