Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. I Hot
  4. SWHC-4K

Solar inverter · I Hot · CEC approved December 2025

I Hot SWHC-4K

A 3.8 kW single-phase solar inverter.

Rated power
3.8kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SWHC-4K: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.8kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
25yr
How long I HOT PTY LTD stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the I Hot SWHC-4K, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP68
Installation requirements
Top clearance50 mm
Side clearance150 mm
AC breaker63 A
Cable gauge16 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time6 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
17 Dec 2025
Approval expiry
17 Dec 2028
Status
Active
Listed for STCs
Yes

About I Hot

Years on the CEC list
1 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
1
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
15.9 kWh
Annual yield
5,817 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

1 years on the CEC list

How it compares

The I Hot SWHC-4K against the closest-power inverters from other brands.

Specification
I Hot SWHC-4KI Hot
Fronius Symo 3.7-3-MFronius
Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2Hiconics Eco-energy Drive Technology
Rated power?3.75 kW3.7 kW3.8 kW✓highest
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseThree-phaseSingle-phase
TypeSolarSolarHybrid
Battery readyNoNoYes
Warranty25 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

25-year inverter warranty

I Hot SWHC-4K

Enphase offers a 25-year warranty on microinverters, covering product defects but excluding damages from improper installations. To claim, contact customer support for a replacement.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Improper installation, unauthorized modifications, and damage from tampering voids the warranty.
Environment limits
Damage due to flooding, lightning strikes, and salt spray are excluded.
Read the official warranty document (PDF)

Fault & error codes — I Hot SWHC-4K

From the install manual

10 documented

Showing 10 of 10. The official install manual is the authoritative source — always confirm before acting.

  • F15criticalCall your installer
    Manual (PDF)

    AC Over Current Failure

    Likely cause
    It is usually caused by loads too large for the inverter. If Off-Grid, the battery discharge Amps are programmed too low. Overloads can result in multiple fault codes.
    What to do
    Reduce the loads or adjust battery discharge settings.
  • F16criticalCall your installer
    Manual (PDF)

    GFCI Failure

    Likely cause
    Ground fault. Check PV+ or PV-wiring (which must be ungrounded). Exposed PV conductors + rain can also cause issues. Check that the neutral line and Ground are not double-bonded.
    What to do
    Check wiring and grounding to prevent ground faults.
  • F20criticalCall your installer
    Manual (PDF)

    DC Over Current Fault

    Likely cause
    It is typically caused by DC current from the inverter, especially if off-Grid with too many parallel strings. Overloads can result in multiple fault codes.
    What to do
    Check and reduce the number of parallel strings or adjust settings.
  • F63criticalCall your installer
    Manual (PDF)

    Arc Fault

    Likely cause
    Can be a poor PV connector/connection or sometimes a false alarm due to powerful lighting storms.
    What to do
    Inspect the PV connections and evaluate for any damage.
  • F82criticalCall your installer
    Manual (PDF)

    Battery Over Voltage Fault

    Likely cause
    Check battery voltage levels; voltage should not be above the specified limits.
    What to do
    Inspect battery charging methods and settings.
  • F65warning
    Manual (PDF)

    Heatsink High Temp Fault

    Likely cause
    Check that the built-in fans are running; the ambient temperature may be too high. Ensure proper clearance.
    What to do
    Ensure adequate ventilation and fan operation.
  • F8warningCall your installer
    Manual (PDF)

    GFDI Relay Failure

    Likely cause
    Check for continuity on the inverter's neutral and ground. Ensure there is only ONE neutral-to-ground bond in the Inverter. Current leakage from inverter AC output to Ground, check Ground and neutral are connected at the main panel.
    What to do
    Inspect grounding and neutral connections
  • F81warningCall your installer
    Manual (PDF)

    DC Low Voltage Fault

    Likely cause
    The battery could be overly discharged or the inverter is off-grid and exceeded programmed battery discharge current.
    What to do
    Charge the batteries to recommended voltage levels.
  • F1info
    Manual (PDF)

    DC Inversed Failure

    Likely cause
    If you have parallel systems and turn one system off, you will get this notification. NOT a fault.
    What to do
    No action needed; this is a notification only.
  • F70info
    Manual (PDF)

    Button Manual OFF

    Likely cause
    The parallel Slave system turned off without turning off the Master.
    What to do
    No action needed; check system operation.

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?