Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Hiconics Eco-energy Drive Technology
  4. HEC2-S3.8Hr2

Hybrid inverter · Hiconics Eco-energy Drive Technology · CEC approved June 2024

Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2

CEC listing: HEC2-S3.8Hr2 (AS4777-2 2020)

A 3.8 kW single-phase hybrid inverter that is battery-ready.

Rated power
3.8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

HEC2-S3.8Hr2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.8kW
How much solar it can turn into usable power at once
Max efficiency
97.4%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Hiconics Eco-energy Drive Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.4%
DC input & MPPT
MPPT trackers2
Physical
Weight12 kg
IP ratingIP65
Operating temperature-20°C to 55°C
Installation requirements
AC breaker32 A
Cable gauge6 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
7 June 2024
Approval expiry
7 June 2027
Status
Active
Listed for STCs
Yes

About Hiconics Eco-energy Drive Technology

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
16.1 kWh
Annual yield
5,895 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2 against the closest-power inverters from other brands.

Specification
Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2Hiconics Eco-energy Drive Technology
Hiconics Eco-energy Drive Technology MD-HI3.8-SHOHiconics Eco-energy Drive Technology
Hiconics Eco-energy Drive Technology MEI2-HS3.8H-AIO1Hiconics Eco-energy Drive Technology
Rated power?3.8 kW3.8 kW3.8 kW
Max efficiency?97.4%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty terms and installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2

This warranty covers the inverter system against defects in materials and workmanship for 5 years. Key exclusions are related to improper installation or unauthorized modifications. To make a claim, contact the manufacturer with proof of purchase and installation.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, and self-servicing may void the warranty.
Environment limits
None specified.
Read the official warranty document (PDF)

Fault & error codes — Hiconics Eco-energy Drive Technology HEC2-S3.8Hr2

From the install manual

12 documented

Showing 12 of 12. The official install manual is the authoritative source — always confirm before acting.

  • BATT-04criticalCall your installer
    Manual (PDF)

    Battery overvoltage alarm

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BATT-05criticalCall your installer
    Manual (PDF)

    Battery undervoltage alarm

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BATT-06criticalCall your installer
    Manual (PDF)

    Battery overtemperature alarm

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BATT-07criticalCall your installer
    Manual (PDF)

    Battery under temperature alarm

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BATT-08criticalCall your installer
    Manual (PDF)

    Battery overcurrent alarm

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BATT-09criticalCall your installer
    Manual (PDF)

    Battery voltage difference too large

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • BMS-03criticalCall your installer
    Manual (PDF)

    BMS communication failure

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • DSP-02criticalCall your installer
    Manual (PDF)

    DSP communication failure

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • NVM-01criticalCall your installer
    Manual (PDF)

    NVM checksum failure

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect them. Contact the dealer if the issue persists.
  • SOC-11criticalCall your installer
    Manual (PDF)

    Battery SOC too high

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • SOC-12criticalCall your installer
    Manual (PDF)

    Battery SOC too low

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.
  • TEMP-10criticalCall your installer
    Manual (PDF)

    Temperature difference too large

    Likely cause
    AC output switch, DC input switch, or Battery switch may be disconnected
    What to do
    Disconnect the AC, DC, and battery switches, wait 5 minutes, and reconnect. Contact the dealer if the issue continues.

More Hiconics Eco-energy Drive Technology Co Ltd inverters

MD-HI3.8-SHO (AS4777-2 2020)

3.8 kW · 1φ

MEI2-HS3.8H-AIO1 (AS4777-2 2020)

3.8 kW · 1φ

MH-HYIV3.8-SHE-AU (AS4777-2 2020)

3.8 kW · 1φ

HEC-S 3K (AS4777-2 2020)

3.68 kW · 1φ

MEI2-HS3.68H-AIO1 (AS4777-2 2020)

3.68 kW · 1φ

MH-HYIV3.68-SHE-AU (AS4777-2 2020)

3.68 kW · 1φ

View all Hiconics Eco-energy Drive Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?