Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. FoxESS
  4. H3-5.0-Smart

Hybrid inverter · FoxESS · CEC approved July 2025

FoxESS H3-5.0-Smart

CEC listing: H3-5.0-Smart (AS4777-2 2020)

A 5 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

H3-5.0-Smart: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
MPPT trackers
3
3 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long FOXESS CO LTD stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the FoxESS H3-5.0-Smart, by section.

Full datasheet, by section
SpecificationValue
DC input & MPPT
MPPT trackers3
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance500 mm
Side clearance100 mm
AC breaker50 A
Cable gauge12 mm²
Earthing methodMen
DNSP pre-approvalYes
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
3 July 2025
Approval expiry
3 July 2028
Status
Active
Listed for STCs
Yes

About FoxESS

Years on the CEC list
7 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
148
CEC-approved batteries
172
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

au.fox-ess.com
7 years on the CEC list

How it compares

The FoxESS H3-5.0-Smart against the closest-power inverters from other brands.

Specification
FoxESS H3-5.0-SmartFoxESS
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?3Not on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

FoxESS H3-5.0-Smart

This warranty covers the inverter for 10 years, ensuring it operates effectively under normal conditions. It excludes damage from improper installation and misuse. Claims can be made via phone or by visiting our website.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications made by unauthorized personnel, or tampering.
Environment limits
High humidity environments, extreme temperatures exceeding -25°C to +60°C, and exposure to corrosive conditions.
Read the official warranty document (PDF)

Fault & error codes — FoxESS H3-5.0-Smart

From the install manual

49 documented

Showing 49 of 49. The official install manual is the authoritative source — always confirm before acting.

  • Bms ChgReq NoAckcriticalCall your installer
    Manual (PDF)

    No action for charging request.

    Likely cause
    Interruptions in charging communication.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Ext FaultcriticalCall your installer
    Manual (PDF)

    The communication between BMS and inverter is interrupted.

    Likely cause
    Communication failure with external BMS.
    What to do
    Check if the communication cable between BMS and inverter is correctly and well connected. Seek help if not resolved.
  • Bms Insul FaultcriticalCall your installer
    Manual (PDF)

    Battery insulation fault.

    Likely cause
    Compromised insulation affecting battery safety.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BMS LostcriticalCall your installer
    Manual (PDF)

    The communication between BMS and inverter is interrupted.

    Likely cause
    Disrupted connection to battery management system.
    What to do
    Check if the communication cable between BMS and inverter is correctly and well connected. Seek help if not resolved.
  • Bms M&S UnmatchcriticalCall your installer
    Manual (PDF)

    The software between Master and Slave are not matched.

    Likely cause
    Inconsistent software across components.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Mfg UnmatchcriticalCall your installer
    Manual (PDF)

    The cell manufacture is different.

    Likely cause
    Mixed components from different manufacturers.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Relay FaultcriticalCall your installer
    Manual (PDF)

    Battery relay fault.

    Likely cause
    Failure in battery relay operation.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms SwHw UnmatchcriticalCall your installer
    Manual (PDF)

    The slave software and hardware are not matched.

    Likely cause
    Incompatible configurations in battery packs.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Type UnmatchcriticalCall your installer
    Manual (PDF)

    The capacity of battery packs is different.

    Likely cause
    Incompatible battery components.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Ver UnmatchcriticalCall your installer
    Manual (PDF)

    The software between slaves are not matched.

    Likely cause
    Divergent software versions in battery packs.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BmsCircuit FaultcriticalCall your installer
    Manual (PDF)

    BMS hardware circuit fault.

    Likely cause
    Component failure in battery management system.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BmsCurSen FaultcriticalCall your installer
    Manual (PDF)

    Battery current sensor fault.

    Likely cause
    Malfunction in current sensing components.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BmsTempSen FaultcriticalCall your installer
    Manual (PDF)

    Battery temperature sensor fault.

    Likely cause
    Malfunction in temperature sensing components.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BmsVoltsSen FaultcriticalCall your installer
    Manual (PDF)

    Battery voltage sensor fault.

    Likely cause
    Malfunction in voltage sensing components.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • DCI FaultcriticalCall your installer
    Manual (PDF)

    DC component is out of limit in output current.

    Likely cause
    Inappropriate output current readings.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • Ground FaultcriticalCall your installer
    Manual (PDF)

    The ground connection is failed.

    Likely cause
    Improper ground connections.
    What to do
    Check the voltage of neutral and PE. Check AC wiring. Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • HW Bat Cur FaultcriticalCall your installer
    Manual (PDF)

    Battery current high detected by hardware.

    Likely cause
    Potential hardware issue with the battery.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • HW Bus Volt FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by hardware.

    Likely cause
    Inadequate bus voltage levels.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • HW Inv Cur FaultcriticalCall your installer
    Manual (PDF)

    Output current high detected by hardware.

    Likely cause
    Potential hardware fault causing high current readings.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • HW Pv Cur FaultcriticalCall your installer
    Manual (PDF)

    PV input current high detected by hardware.

    Likely cause
    Potential mismatch in PV connections.
    What to do
    Check whether PV positive and negative are connected. Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • Iso FaultcriticalCall your installer
    Manual (PDF)

    The isolation is failed.

    Likely cause
    Damaged insulation in electric wires.
    What to do
    Check if the insulation of electric wires is damaged. Wait for a while to check if back to normal. Seek help if not resolved.
  • MDSP SPI FaultcriticalCall your installer
    Manual (PDF)

    The communication between master and slave is fail.

    Likely cause
    Communication interruption.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • Meter Lost FaultcriticalCall your installer
    Manual (PDF)

    The communication between meter and inverter is interrupted.

    Likely cause
    Disruption in meter connection.
    What to do
    Check if the communication cable between meter and inverter is correctly and well connected. Seek help if not resolved.
  • RDSP Smpl FaultcriticalCall your installer
    Manual (PDF)

    The slave sample detection circuit is failed.

    Likely cause
    Improper component functioning.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • Res Cur FaultcriticalCall your installer
    Manual (PDF)

    The residual current is high.

    Likely cause
    Damaged insulation or leakage in wiring.
    What to do
    Check if the insulation of electric wires is damaged. Wait for a while to check if back to normal. Seek help if not resolved.
  • SCI FaultcriticalCall your installer
    Manual (PDF)

    The communication between master and manager is fail.

    Likely cause
    Communication failure between components.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • SW Bat Cur FaultcriticalCall your installer
    Manual (PDF)

    Battery current high detected by software.

    Likely cause
    Overcurrent scenario detected in the battery.
    What to do
    Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • SW Bus Vol FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by software.

    Likely cause
    Inadequate connection of N line to the grid port.
    What to do
    Check the N line connection to the GRID port of the inverter. Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • SW Inv Cur FaultcriticalCall your installer
    Manual (PDF)

    Output current high detected by software.

    Likely cause
    Overcurrent situation detected.
    What to do
    To upgrade to the latest software, ensure the master is upgraded to 1.69 or above. Disconnect PV, grid, and battery, then reconnect. Seek help if not resolved.
  • 10min Volt Faultwarning
    Manual (PDF)

    The grid voltage is out of range for the last 10 Minutes.

    Likely cause
    Consistent out-of-range voltage conditions.
    What to do
    System will reconnect if the utility voltage is back to normal. Seek help if not resolved.
  • Bat Power Lowwarning
    Manual (PDF)

    The battery power is low.

    Likely cause
    Insufficient battery charge.
    What to do
    Wait for the battery to be recharged. Seek help if not resolved.
  • Bat Volt Faultwarning
    Manual (PDF)

    Battery voltage fault.

    Likely cause
    Inappropriate battery input voltage levels.
    What to do
    Check if the battery input voltage is within the normal range. Seek help if not resolved.
  • Bms ChgCur HighwarningCall your installer
    Manual (PDF)

    Battery charge over current.

    Likely cause
    Excessive current flowing into the battery.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms DchgCur HighwarningCall your installer
    Manual (PDF)

    Battery discharge over current.

    Likely cause
    Excessive current draining from the battery.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms HW ProtectwarningCall your installer
    Manual (PDF)

    Battery hardware under protection.

    Likely cause
    Protection measures triggered by abnormal conditions.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Int Faultwarning
    Manual (PDF)

    DIP switch at the wrong position; The communication between battery packs is interrupted.

    Likely cause
    Improper configuration of DIP switch affecting communication.
    What to do
    Move the DIP switch to the correct position. Check if the communication cable between battery packs is correctly and well connected. Seek help if not resolved.
  • Bms Temp HighwarningCall your installer
    Manual (PDF)

    Battery over temperature.

    Likely cause
    High ambient temperature or malfunctioning cooling systems.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Temp LowwarningCall your installer
    Manual (PDF)

    Battery under temperature.

    Likely cause
    Low temperature affecting battery performance.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Volt HighwarningCall your installer
    Manual (PDF)

    Battery over voltage.

    Likely cause
    Voltage levels exceeding battery specifications.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Bms Volt LowwarningCall your installer
    Manual (PDF)

    Battery under voltage.

    Likely cause
    Inadequate battery charge levels.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • BmsCellImbalancewarningCall your installer
    Manual (PDF)

    The capacities of cells are different.

    Likely cause
    Variations in battery cell performance.
    What to do
    Please contact battery supplier. Seek help if not resolved.
  • Eps Over Loadwarning
    Manual (PDF)

    Over load in off grid mode.

    Likely cause
    The EPS load power exceeds the limit.
    What to do
    Check if the EPS load power exceeds the limit. Seek help if not resolved.
  • Grid Freq Faultwarning
    Manual (PDF)

    Grid frequency out of range.

    Likely cause
    Frequency levels exceeding permitted limits.
    What to do
    System will reconnect if utility frequency is back to normal. Seek help if not resolved.
  • Grid Lost Faultwarning
    Manual (PDF)

    Grid is lost.

    Likely cause
    Utility power has been interrupted.
    What to do
    System will reconnect if the utility is back to normal. Seek help if not resolved.
  • Grid Volt Faultwarning
    Manual (PDF)

    Grid voltage out of range.

    Likely cause
    Voltage levels exceeding permitted limits.
    What to do
    System will reconnect if utility voltage is back to normal. Seek help if not resolved.
  • Over Load Faultwarning
    Manual (PDF)

    Over load in on grid mode.

    Likely cause
    The load power exceeds the limit.
    What to do
    Check if the load power exceeds the limit. Seek help if not resolved.
  • PLL_OverTimewarning
    Manual (PDF)

    Three-phase system access single-phase AC.

    Likely cause
    Improper grid connection.
    What to do
    System will reconnect if the utility is back to normal. Seek help if not resolved.
  • Pv Volt Faultwarning
    Manual (PDF)

    PV voltage out of range.

    Likely cause
    Voltage levels of PV panels exceeding limits.
    What to do
    Check the output voltage of PV panels. Seek help if not resolved.
  • Temp Faultwarning
    Manual (PDF)

    The inverter temperature is high.

    Likely cause
    Inadequate cooling or high ambient temperature.
    What to do
    Check if the environment temperature is appropriate. Wait for a while to check if back to normal. Seek help if not resolved.

More FOXESS CO LTD inverters

1K5-HI-5-V1 (AS4777-2 2020)

5 kW · 3φ

PQ3-5.0-M_EQ5500-S_2S (AS4777-2 2020)

5 kW · 3φ

PQ3-5.0-M_EQ5500-S_3S (AS4777-2 2020)

5 kW · 3φ

PQ3-5.0-M_EQ5500-S_4S (AS4777-2 2020)

5 kW · 3φ

PQ3-5.0-M_EQ5500-S_5S (AS4777-2 2020)

5 kW · 3φ

PQ3-5.0-M_EQ5500-S_6S (AS4777-2 2020)

5 kW · 3φ

View all FOXESS CO LTD inverters

More from FoxESS

Other CEC-approved products from FoxESS available in Australia.

FoxESS Batteries

1K5-BAT-4660-L2

9.32 kWh · LFP

1K5-BAT-4660-L3

13.98 kWh · LFP

1K5-BAT-4660-L4

18.64 kWh · LFP

1K5-BAT-4660-L5

23.3 kWh · LFP

1K5-BAT-4660-L6

27.96 kWh · LFP

1K5-BAT-4660-L7

32.61 kWh · LFP

View all FoxESS batteries
View full FoxESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?