Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. FoxESS
  4. G9

Solar inverter · FoxESS · Not listed as CEC approved

FoxESS G9

CEC listing: G9 (AS4777-2 2020)

A 9 kW single-phase solar inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
9kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

G9: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • The register doesn't currently list it as CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
9kW
How much solar it can turn into usable power at once
Max efficiency
97.4%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
10yr
How long FOXESS CO LTD stands behind it

Full datasheet

Every figure on file for the FoxESS G9, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.4%
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker50 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time14 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
27 Oct 2025
Approval expiry
28 May 2027
Status
Not listed
Listed for STCs
No (not listed)

About FoxESS

Years on the CEC list
7 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
148
CEC-approved batteries
172
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
38.3 kWh
Annual yield
13,961 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

au.fox-ess.com
7 years on the CEC list

How it compares

The FoxESS G9 against the closest-power inverters from other brands.

Specification
FoxESS G9FoxESS
Energizer Force 9.0HS+Energizer
Energizer Force 9.0SEnergizer
Rated power?9 kW9 kW9 kW
Max efficiency?97.4%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab

10-year inverter warranty

FoxESS G9

This warranty covers EQ series products for 10 years, excluding improper installations and environmental conditions. Claims must be made within 3 months of the last online connection.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Improper installation by non-accredited installers; unauthorized modifications or repairs; non-compliance with operating instructions.
Environment limits
Ambient temperature must not fall below -10°C (14°F) or exceed 50°C (122°F).
Read the official warranty document (PDF)

Fault & error codes — FoxESS G9

From the install manual

22 documented

Showing 22 of 22. The official install manual is the authoritative source — always confirm before acting.

  • Bus OVPcriticalCall your installer
    Manual (PDF)

    Bus over voltage

    Likely cause
    PV voltage too high
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • Comm LostcriticalCall your installer
    Manual (PDF)

    Communication lost

    Likely cause
    Issues with communication connections
    What to do
    Disconnect PV (+) and PV (-), reconnect them.
  • Consistent FaultcriticalCall your installer
    Manual (PDF)

    Consistent fault detected

    Likely cause
    Persistent issue with inverter operation
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • DCI FaultcriticalCall your installer
    Manual (PDF)

    DC interface fault

    Likely cause
    Problem with DC connection
    What to do
    Wait for one minute after the inverter reconnects to grid, disconnect PV (+) and PV (-) with DC.
  • EEPROM FaultcriticalCall your installer
    Manual (PDF)

    EEPROM fault detected

    Likely cause
    EEPROM error or communication issue
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • GFC FaultcriticalCall your installer
    Manual (PDF)

    Ground fault detected

    Likely cause
    Fault in AC circuit or grounding issue
    What to do
    Disconnect DC and AC connector, check surrounding equipment on the AC side, reconnect input connector and check inverter state after troubleshooting.
  • GFCD FaultcriticalCall your installer
    Manual (PDF)

    Ground fault circuit detection fault

    Likely cause
    Fault in grounding circuit
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • Grid 10Min OVPcriticalCall your installer
    Manual (PDF)

    Grid over voltage

    Likely cause
    Grid voltage exceeded limits
    What to do
    System will reconnect if the grid is back to normal, otherwise seek help.
  • Ground FaultcriticalCall your installer
    Manual (PDF)

    Ground fault detected

    Likely cause
    Devices not correctly grounded
    What to do
    Check voltage of neutral and PE, AC wiring. Restart inverter; seek help if error message persists.
  • Isolation FaultcriticalCall your installer
    Manual (PDF)

    Isolation fault detected (Australia market only)

    Likely cause
    Impedance issue between PV lines and ground
    What to do
    Check impedance; it should be >1Mohm. Seek help if undetectable or <1Mohm.
  • MS Comm LostcriticalCall your installer
    Manual (PDF)

    Master communication lost

    Likely cause
    Fault in master connection
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • OCPcriticalCall your installer
    Manual (PDF)

    Over current protection activated

    Likely cause
    PV and grid connections too high
    What to do
    Turn off the PV and grid, reconnect them.
  • Over TempcriticalCall your installer
    Manual (PDF)

    Over temperature fault

    Likely cause
    Operating environment too hot
    What to do
    Check if the environment temperature is over the limit; seek help if persists.
  • PLL FaultcriticalCall your installer
    Manual (PDF)

    Phase locked loop fault

    Likely cause
    Utility grid instability
    What to do
    System will reconnect if the utility is back to normal; seek help otherwise.
  • Relay FailcriticalCall your installer
    Manual (PDF)

    Relay failure detected

    Likely cause
    Internal relay issue
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • Sample FaultcriticalCall your installer
    Manual (PDF)

    Sampling fault detected

    Likely cause
    Internal sampling error
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.
  • Grid Freq FaultwarningCall your installer
    Manual (PDF)

    Grid frequency fault

    Likely cause
    Grid frequency outside acceptable range
    What to do
    Wait for one minute, grid may go back to normal working state, or seek help if issue persists.
  • Grid Lost FaultwarningCall your installer
    Manual (PDF)

    Lost connection to the grid

    Likely cause
    Grid connection issue
    What to do
    Check grid connection, e.g., wires, interfaces, and ensure grid usability.
  • Grid Voltage FaultwarningCall your installer
    Manual (PDF)

    Grid voltage fault

    Likely cause
    Grid voltage outside standards
    What to do
    Wait for one minute, grid may go back to normal working state, or seek help if issue persists.
  • PV OVPwarningCall your installer
    Manual (PDF)

    PV open voltage over limit

    Likely cause
    Panel voltage too high
    What to do
    Check panel's open-circuit voltage and seek help if ≤550Vdc.
  • SPS FaultwarningCall your installer
    Manual (PDF)

    SPS fault detected

    Likely cause
    Possible connection issue with PV and grid
    What to do
    Turn off the PV and grid, reconnect them.
  • VGridTransient FaultwarningCall your installer
    Manual (PDF)

    Transient grid voltage fault

    Likely cause
    Temporary fluctuations in grid voltage
    What to do
    Disconnect PV (+) and PV (-) with DC. After the LCD switches off, reconnect and check again.

More FOXESS CO LTD inverters

1K5-1P-HI-9 (AS4777-2 2020)

9 kW · 1φ

G9 (AS4777-2 2020)

9 kW · 1φ

KH9 (AS4777-2 2020)

9 kW · 1φ

1K5-1P-HI-9.9 (AS4777-2 2020)

9.9 kW · 1φ

KA9.9 (AS4777-2 2020)

9.9 kW · 1φ

KH9.9 (AS4777-2 2020)

9.9 kW · 1φ

View all FOXESS CO LTD inverters

More from FoxESS

Other CEC-approved products from FoxESS available in Australia.

FoxESS Batteries

1K5-BAT-4660-L2

9.32 kWh · LFP

1K5-BAT-4660-L3

13.98 kWh · LFP

1K5-BAT-4660-L4

18.64 kWh · LFP

1K5-BAT-4660-L5

23.3 kWh · LFP

1K5-BAT-4660-L6

27.96 kWh · LFP

1K5-BAT-4660-L7

32.61 kWh · LFP

View all FoxESS batteries
View full FoxESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?