Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. FoxESS
  4. 1K5-1P-HI-9

Hybrid inverter · FoxESS · CEC approved May 2025

FoxESS 1K5-1P-HI-9

CEC listing: 1K5-1P-HI-9 (AS4777-2 2020)

A 9 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
9kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

1K5-1P-HI-9: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
9kW
How much solar it can turn into usable power at once
Max efficiency
97.8%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long FOXESS CO LTD stands behind it

Full datasheet

Every figure on file for the FoxESS 1K5-1P-HI-9, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.8%
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
AC breaker25 A
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
29 May 2025
Approval expiry
29 May 2028
Status
Active
Listed for STCs
Yes

About FoxESS

Years on the CEC list
7 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
148
CEC-approved batteries
172
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
38.3 kWh
Annual yield
13,961 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

au.fox-ess.com
7 years on the CEC list

How it compares

The FoxESS 1K5-1P-HI-9 against the closest-power inverters from other brands.

Specification
FoxESS 1K5-1P-HI-9FoxESS
Energizer Force 9.0HS+Energizer
Energizer Force 9.0SEnergizer
Rated power?9 kW9 kW9 kW
Max efficiency?97.8%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

FoxESS 1K5-1P-HI-9

Fox ESS offers a 10-year warranty covering defects in materials and workmanship for its inverters and charge controllers. It excludes coverage for non-accredited installations and modifications; claims must be made by authorized installers.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
non-accredited installation, modification, improper installation, improper use or misuse, force majeure events, unauthorized repairs
Environment limits
none stated
Read the official warranty document (PDF)

Fault & error codes — FoxESS 1K5-1P-HI-9

From the install manual

70 documented

Showing 70 of 70. The official install manual is the authoritative source — always confirm before acting.

  • ARM EEPROM FaultcriticalCall your installer
    Manual (PDF)

    The manager eeprom is fault.

    Likely cause
    Failure of EEPROM in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Bat Boost FaultcriticalCall your installer
    Manual (PDF)

    The battery boost circuit mosfet is fail.

    Likely cause
    Malfunction in boost circuit.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Bat Buck FaultcriticalCall your installer
    Manual (PDF)

    The battery buck circuit mosfet is fail.

    Likely cause
    Malfunction in charging circuit.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Bat Relay OpencriticalCall your installer
    Manual (PDF)

    The battery relay keeps open.

    Likely cause
    Malfunction in battery relay.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Bat Relay Short CircuitcriticalCall your installer
    Manual (PDF)

    The battery relay keeps close.

    Likely cause
    Malfunction in battery relay.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Bat Volt FaultcriticalCall your installer
    Manual (PDF)

    Battery voltage fault.

    Likely cause
    Battery malfunction or disconnection.
    What to do
    Check if the battery input voltage is within the normal range.
  • BatCon Dir FaultcriticalCall your installer
    Manual (PDF)

    The battery connection is reversed.

    Likely cause
    Incorrectly connected battery terminals.
    What to do
    Check if the positive pole and negative pole of battery are correctly connected, or seek help.
  • Bms ChgCur HighcriticalCall your installer
    Manual (PDF)

    Battery charge over current.

    Likely cause
    Malfunction in charging system.
    What to do
    Please contact service department.
  • Bms DchgCur HighcriticalCall your installer
    Manual (PDF)

    Battery discharge over current.

    Likely cause
    Malfunction in discharge system.
    What to do
    Please contact service department.
  • Bms HW ProtectcriticalCall your installer
    Manual (PDF)

    Battery hardware under protection.

    Likely cause
    Battery hardware malfunction.
    What to do
    Please contact service department.
  • Bms Insul FaultcriticalCall your installer
    Manual (PDF)

    Battery insulation fault.

    Likely cause
    Damaged insulation of battery cables.
    What to do
    Please contact service department.
  • Bms M&S UnmatchcriticalCall your installer
    Manual (PDF)

    The software between Master and Slave are not match.

    Likely cause
    Inconsistent configurations.
    What to do
    Please contact service department.
  • Bms Mfg UnmatchcriticalCall your installer
    Manual (PDF)

    The cell manufacture is different.

    Likely cause
    Battery cells from different manufacturers.
    What to do
    Please contact service department.
  • Bms Relay FaultcriticalCall your installer
    Manual (PDF)

    Battery relay fault.

    Likely cause
    Failure of relay.
    What to do
    Please contact service department.
  • Bms SwHw UnmatchcriticalCall your installer
    Manual (PDF)

    The slave software and hardware are not match.

    Likely cause
    Incompatible software and hardware configurations.
    What to do
    Please contact service department.
  • Bms Temp HighcriticalCall your installer
    Manual (PDF)

    Battery over temperature.

    Likely cause
    Overheating of battery.
    What to do
    Please contact service department.
  • Bms Type UnmatchcriticalCall your installer
    Manual (PDF)

    The capacity of battery packs is different.

    Likely cause
    Mismatch in battery specifications.
    What to do
    Please contact service department.
  • Bms Volt HighcriticalCall your installer
    Manual (PDF)

    Battery over voltage.

    Likely cause
    Battery malfunction or overcharging.
    What to do
    Please contact service department.
  • Bms Volt LowcriticalCall your installer
    Manual (PDF)

    Battery under voltage.

    Likely cause
    Battery discharging or failure.
    What to do
    Please contact service department.
  • BmsCircuit FaultcriticalCall your installer
    Manual (PDF)

    Bms hardware circuit fault.

    Likely cause
    Fault in battery management system.
    What to do
    Please contact service department.
  • BmsCurSen FaultcriticalCall your installer
    Manual (PDF)

    Battery current sensor fault.

    Likely cause
    Failure of sensor.
    What to do
    Please contact service department.
  • BmsTempSen FaultcriticalCall your installer
    Manual (PDF)

    Battery temperature sensor fault.

    Likely cause
    Failure of sensor.
    What to do
    Please contact service department.
  • BmsVoltsSen FaultcriticalCall your installer
    Manual (PDF)

    Battery voltage sensor fault.

    Likely cause
    Failure of sensor.
    What to do
    Please contact service department.
  • Dci Cons FaultcriticalCall your installer
    Manual (PDF)

    The dci sample value between master and slave is not consistent.

    Likely cause
    Data communication issue.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • DCI FaultcriticalCall your installer
    Manual (PDF)

    DC component is out of limit in output current.

    Likely cause
    Malfunction in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Eps Over LoadcriticalCall your installer
    Manual (PDF)

    Over load in off grid mode.

    Likely cause
    Excessive load on EPS.
    What to do
    Check if the EPS load power exceeds the limit, or seek help.
  • Eps Relay FaultcriticalCall your installer
    Manual (PDF)

    The eps relay is failed.

    Likely cause
    Malfunction in EPS relay.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Grid Lost FaultcriticalCall your installer
    Manual (PDF)

    Grid is lost.

    Likely cause
    Utility power outage.
    What to do
    System will reconnect if the utility returns. If not, seek help.
  • GridF Cons FaultcriticalCall your installer
    Manual (PDF)

    The grid frequency sample value between master and slave is not consistent.

    Likely cause
    Data communication issue.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • GridV Cons FaultcriticalCall your installer
    Manual (PDF)

    The grid voltage sample value between master and slave is not consistent.

    Likely cause
    Data communication issue.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Ground FaultcriticalCall your installer
    Manual (PDF)

    The ground connection is failed.

    Likely cause
    Poor grounding or wiring issues.
    What to do
    Check voltage of neutral and PE, check AC wiring, disconnect PV, grid, and battery, then reconnect, or seek help.
  • HW Bus Vol FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by hardware.

    Likely cause
    Malfunction in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Inv EEPROM FaultcriticalCall your installer
    Manual (PDF)

    The inverter eeprom is fault.

    Likely cause
    Failure of EEPROM storage in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Iso FaultcriticalCall your installer
    Manual (PDF)

    The isolation is failed.

    Likely cause
    Damaged insulation or wiring.
    What to do
    Check insulation of electric wires, wait to see if it returns to normal, or seek help.
  • M1 Close FaultcriticalCall your installer
    Manual (PDF)

    The grid relay M1 keep close.

    Likely cause
    Fault in the relay system.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • M2 Close FaultcriticalCall your installer
    Manual (PDF)

    The grid relay M2 keep close.

    Likely cause
    Fault in the relay system.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Main Relay OpencriticalCall your installer
    Manual (PDF)

    The grid relay keeps open.

    Likely cause
    Fault in the relay system.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • MDSP Smpl FaultcriticalCall your installer
    Manual (PDF)

    The master sample detection circuit is failed.

    Likely cause
    Malfunction in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Over Load FaultcriticalCall your installer
    Manual (PDF)

    Over load in on grid mode.

    Likely cause
    Connected load exceeds inverter capacity.
    What to do
    Check if the load power exceeds the limit, or seek help.
  • PvCon Dir FaultcriticalCall your installer
    Manual (PDF)

    The PV connection is reversed.

    Likely cause
    Incorrectly connected PV terminals.
    What to do
    Check if the positive pole and negative pole of PV are correctly connected, or seek help.
  • Rc Cons FaultcriticalCall your installer
    Manual (PDF)

    The residual current sample value between master and slave is not consistent.

    Likely cause
    Data communication issue.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • RDSP Smpl FaultcriticalCall your installer
    Manual (PDF)

    The slave sample detection circuit is failed.

    Likely cause
    Malfunction in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Res Cur FaultcriticalCall your installer
    Manual (PDF)

    The residual current is high.

    Likely cause
    Possible electrical leakage.
    What to do
    Check insulation of electric wires, wait to see if it returns to normal, or seek help.
  • Res Cur HW FaultcriticalCall your installer
    Manual (PDF)

    Residual current detection device is failed.

    Likely cause
    Malfunction in residual current device.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • S1 Close FaultcriticalCall your installer
    Manual (PDF)

    The grid relay S1 keep close.

    Likely cause
    Fault in the relay system.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • S2 Close FaultcriticalCall your installer
    Manual (PDF)

    The grid relay S2 keep close.

    Likely cause
    Fault in the relay system.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • SW Bus Vol FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by software.

    Likely cause
    Malfunction in the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • 10min Volt FaultwarningCall your installer
    Manual (PDF)

    The grid voltage is out of range for the last 10 minutes.

    Likely cause
    Prolonged voltage fluctuation.
    What to do
    System will reconnect if the utility returns to normal. Otherwise, seek help.
  • Bms ChgReq NoAckwarningCall your installer
    Manual (PDF)

    No action for charging request.

    Likely cause
    Communication failure with the charging request.
    What to do
    Please contact service department.
  • Bms Ext FaultwarningCall your installer
    Manual (PDF)

    The communication between BMS and Inverter is interrupted.

    Likely cause
    Disconnected or faulty communication cable.
    What to do
    Check if the communication cable between BMS and Inverter is correctly connected.
  • Bms Int FaultwarningCall your installer
    Manual (PDF)

    DIP switch at the wrong position; The communication between battery packs is interrupted.

    Likely cause
    Incorrect DIP switch configuration.
    What to do
    Move the DIP switch to the correct position; check communication cable between battery packs.
  • BMS LostwarningCall your installer
    Manual (PDF)

    The communication between BMS and Inverter is interrupted.

    Likely cause
    Disconnected or faulty communication cable.
    What to do
    Check if the communication cable between BMS and Inverter is correctly connected.
  • Bms Temp LowwarningCall your installer
    Manual (PDF)

    Battery under temperature.

    Likely cause
    Insufficient temperature for operation.
    What to do
    Please contact service department.
  • Bms Ver UnmatchwarningCall your installer
    Manual (PDF)

    The software between slaves are different.

    Likely cause
    Inconsistent software versions.
    What to do
    Please contact service department.
  • BmsCellImbalancewarningCall your installer
    Manual (PDF)

    The capacities of cells are different.

    Likely cause
    Battery cell mismatch.
    What to do
    Please contact service department.
  • Grid Freq FaultwarningCall your installer
    Manual (PDF)

    Grid frequency out of range.

    Likely cause
    Frequency fluctuations in the power supply.
    What to do
    System will reconnect if the utility returns to normal. Otherwise, seek help.
  • Grid Volt FaultwarningCall your installer
    Manual (PDF)

    Grid voltage out of range.

    Likely cause
    Voltage fluctuations in the power supply.
    What to do
    System will reconnect if the utility returns to normal. Otherwise, seek help.
  • HW Bat Cur FaultwarningCall your installer
    Manual (PDF)

    Battery current high detected by hardware.

    Likely cause
    Excessive discharge current.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • HW Inv Cur FaultwarningCall your installer
    Manual (PDF)

    Output current high detected by hardware.

    Likely cause
    Excessive load on the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • HW Pv Cur FaultwarningCall your installer
    Manual (PDF)

    PV input current high detected by hardware.

    Likely cause
    Excessive input from PV panels.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • MDSP SPI FaultwarningCall your installer
    Manual (PDF)

    The communication between master and slave is fail.

    Likely cause
    Malfunction in internal communication.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Meter Lost FaultwarningCall your installer
    Manual (PDF)

    The communication between meter and Inverter is interrupted.

    Likely cause
    Disconnected or faulty communication cable.
    What to do
    Check if the communication cable between meter and Inverter is correctly connected.
  • Pv Volt FaultwarningCall your installer
    Manual (PDF)

    PV voltage out of range.

    Likely cause
    Malfunction in the PV array.
    What to do
    Check the output voltage of PV panels, or seek help.
  • RDSP SPI FaultwarningCall your installer
    Manual (PDF)

    The communication between master and slave is fail.

    Likely cause
    Data communication issue.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • SCI FaultwarningCall your installer
    Manual (PDF)

    The communication between master and manager is fail.

    Likely cause
    Malfunction in internal communication.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • SW Bat Cur FaultwarningCall your installer
    Manual (PDF)

    Battery current high detected by software.

    Likely cause
    Excessive load on the battery.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • SW Inv Cur FaultwarningCall your installer
    Manual (PDF)

    Output current high detected by software.

    Likely cause
    Excessive load on the inverter.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • SW Pv Cur FaultwarningCall your installer
    Manual (PDF)

    PV input current high detected by software.

    Likely cause
    Excessive output from PV.
    What to do
    Disconnect PV, grid, and battery, then reconnect.
  • Temp FaultwarningCall your installer
    Manual (PDF)

    The inverter temperature is high.

    Likely cause
    Insufficient cooling or overheating.
    What to do
    Check the environment temperature, wait to see if it returns to normal or seek help.
  • Bat Power Lowinfo
    Manual (PDF)

    The battery power is low.

    Likely cause
    Battery discharging.
    What to do
    Wait until the battery is recharged.

More FOXESS CO LTD inverters

G9 (AS4777-2 2020)

9 kW · 1φ

G9 (AS4777-2 2020)

9 kW · 1φ

KH9 (AS4777-2 2020)

9 kW · 1φ

1K5-1P-HI-9.9 (AS4777-2 2020)

9.9 kW · 1φ

KA9.9 (AS4777-2 2020)

9.9 kW · 1φ

KH9.9 (AS4777-2 2020)

9.9 kW · 1φ

View all FOXESS CO LTD inverters

More from FoxESS

Other CEC-approved products from FoxESS available in Australia.

FoxESS Batteries

1K5-BAT-4660-L2

9.32 kWh · LFP

1K5-BAT-4660-L3

13.98 kWh · LFP

1K5-BAT-4660-L4

18.64 kWh · LFP

1K5-BAT-4660-L5

23.3 kWh · LFP

1K5-BAT-4660-L6

27.96 kWh · LFP

1K5-BAT-4660-L7

32.61 kWh · LFP

View all FoxESS batteries
View full FoxESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?