Battery inverter · FoxESS · AC1-G2 series · CEC approved January 2024
CEC listing: AC1-3.0-E-G2 (AS4777-2 2020)
A 3 kW single-phase battery inverter.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Rated power
How much solar it can turn into usable power at once
Phases
Runs on a standard single-phase supply
MPPT trackers
2 roof faces can be tuned independently
Type
Runs a battery; pairs with a separate solar inverter
Warranty
How long FOXESS CO LTD stands behind it
Every figure on file for the FoxESS AC1-3.0-E-G2, by section.
| Specification | Value |
|---|---|
| DC input & MPPT | |
| MPPT trackers | 2 |
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| AC breaker | 50 A |
| Cable gauge | 4 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Battery compatible
Yes
Backup capable
Yes
CEC approved
3 Jan 2024
Approval expiry
3 Jan 2027
Status
Active
Eligible for rebates
Yes
Years in AU Market
7 years
Australian Office
Yes
CEC-Approved Batteries
116
CEC-Approved Panels
0
Category
Mid-Tier
Typical installed, inverter only
$900–$1,650
Prices vary by installer, configuration and site complexity. Get exact quotes from installers you choose.
Compare quotes from installers you choose
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead — ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
au.fox-ess.comThe FoxESS AC1-3.0-E-G2 against the closest-power inverters from other brands.
| Specification | FoxESS AC1-3.0-E-G2FoxESS | Energizer FORCE 3.0HSEnergizer | Energizer Force 3SEnergizer |
|---|---|---|---|
| Rated power? | 3 kW | 3 kW | 3 kW |
| Max efficiency? | 0.0% | 0.0% | 0.0% |
| MPPT trackers? | 2 | Not verified | Not verified |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Battery | Hybrid | Solar |
| Battery ready | Yes | Yes | No |
| Warranty | 12 years | Not verified | Not verified |
Specs from the CEC register and datasheet enrichment. Indicative — confirm exact figures with your installer.
The warranty covers defects in materials and workmanship in the solar inverters and chargers for up to 120 months. It does not cover damage from improper installation, modifications, or environmental factors such as storms.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 19 of 19. The official install manual is the authoritative source — always confirm before acting.
DCI FaultcriticalCall your installerDC component is out of limit in output current.
Eps Over LoadcriticalCall your installerOver load in off grid mode.
Ground FaultcriticalCall your installerThe ground connection is failed.
HW Inv Cur FaultcriticalCall your installerOutput current high detected by hardware.
Iso FaultcriticalCall your installerThe isolation is failed.
Over Load FaultcriticalCall your installerOver load in on grid mode.
Res Cur FaultcriticalCall your installerThe residual current is high.
SW Bat Cur FaultcriticalCall your installerBattery current high detected by software.
SW Bus Volt FaultcriticalCall your installerBus voltage out of range detected by software.
SW Inv Cur FaultcriticalCall your installerOutput current high detected by software.
SW Pv Cur FaultcriticalCall your installerPV input current high detected by software.
10min Volt FaultwarningThe grid voltage is out of range for the last 10 Minutes.
Bat Power LowwarningThe battery power is low.
Bat Volt FaultwarningCall your installerBattery voltage fault.
Grid Freq FaultwarningGrid frequency out of range.
Grid Lost FaultwarningGrid is lost.
Grid Volt FaultwarningGrid voltage out of range.
Pv Volt FaultwarningCall your installerPV voltage out of range.
Temp FaultwarningCall your installerThe inverter temperature is high.
Part of the FoxESS AC1-G2 series
Compare every FoxESS AC1-G2 variant side by side →
1K5-1P-HI-10.5 (AS4777-2 2020)
10.5 kW · 1φ
1K5-1P-HI-10 (AS4777-2 2020)
10 kW · 1φ
1K5-1P-HI-3.7 (AS4777-2 2020)
3.68 kW · 1φ
1K5-1P-HI-4.6 (AS4777-2 2020)
4.6 kW · 1φ
1K5-1P-HI-5 (AS4777-2 2020)
5 kW · 1φ
1K5-1P-HI-6 (AS4777-2 2020)
6 kW · 1φ
Other CEC-approved products from FOXESS CO LTD available in Australia.
Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.