Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Eaton Power Quality
  4. 93PCS 375

Battery inverter · Eaton Power Quality · CEC approved June 2025

Eaton Power Quality 93PCS 375

CEC listing: 93PCS 375 (AS4777-2 2020)

A 375 kW three-phase battery inverter.

Rated power
375kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter

Commercial-scale inverter

At 375 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
375kW
How much solar it can turn into usable power at once
Max efficiency
98.6%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
2yr
How long Eaton Power Quality (Shanghai) Co Ltd stands behind it

Full datasheet

Every figure on file for the Eaton Power Quality 93PCS 375, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power125 kW
Efficiency
Max efficiency98.6%
Physical
IP ratingIP20
Operating temperature-25°C to 40°C

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
18 June 2025
Approval expiry
18 June 2028
Status
Active
Listed for STCs
Yes

About Eaton Power Quality

Years on the CEC list
1 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
5
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

1 years on the CEC list

How it compares

The Eaton Power Quality 93PCS 375 against the closest-power inverters from other brands.

Specification
Eaton Power Quality 93PCS 375Eaton Power Quality
Shenzhen Sinexcel Electric PWS1-500KTL-EX-6M1Shenzhen Sinexcel Electric
Shenzhen Sinexcel Electric PWS1-500KTL-EX-6M4Shenzhen Sinexcel Electric
Rated power?375 kW375 kW375 kW
Max efficiency?98.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseSingle-phase
TypeBatterySolarSolar
Battery readyYesNoNo
Warranty2 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty terms and installation guide and user manual and compliance certificatePDF, opens in a new tab

2-year inverter warranty

Eaton Power Quality 93PCS 375

Eaton offers a 24-month warranty from the boot date, provided booting is done by Eaton or authorized engineers. The warranty covers defects but excludes damage from unauthorized modifications and environmental factors.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-Eaton products and components, damage caused by unauthorized installation or maintenance, natural disasters (e.g., earthquakes, fires, floods), and failure to comply with installation and operation instructions void the warranty.
Environment limits
The system is not suitable for outdoor use and should not be operated near water or in humid places (maximum humidity allowed: 95%).
Read the official warranty document (PDF)

Fault & error codes — Eaton Power Quality 93PCS 375

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • Bus voltage anomaliescriticalCall your installer
    Manual (PDF)

    DC bus voltage is too high or too low

    Likely cause
    Fluctuations in DC input voltage
    What to do
    Check the DC voltage sources; restart device after adjustments
  • DC input overvoltagecriticalCall your installer
    Manual (PDF)

    DC input voltage exceeds upper limit

    Likely cause
    External power surge
    What to do
    Disconnect from power source; restart device after stabilization
  • Emergency stopcritical
    Manual (PDF)

    Emergency stop activated

    Likely cause
    Manual emergency stop action or fault detection
    What to do
    Ensure safety protocols; reset device to resume operation
  • Grid frequency anomaliescriticalCall your installer
    Manual (PDF)

    Grid frequency is out of set range

    Likely cause
    Fluctuations in grid frequency
    What to do
    Monitor grid frequency; restart energy storage device after recovery
  • Grid overvoltagecriticalCall your installer
    Manual (PDF)

    Grid voltage exceeds the upper limit

    Likely cause
    External voltage spike or surge
    What to do
    Monitor grid voltage; restart energy storage device after recovery
  • Grid undervoltagecriticalCall your installer
    Manual (PDF)

    Grid voltage falls below the lower limit

    Likely cause
    Drop in grid voltage or power outage
    What to do
    Monitor grid voltage; restart energy storage device after recovery
  • Low DC voltagecriticalCall your installer
    Manual (PDF)

    DC input voltage falls below the lower limit

    Likely cause
    Insufficient input voltage or battery issue
    What to do
    Check DC input sources; replace or recharge batteries if needed
  • Fan failurewarningCall your installer
    Manual (PDF)

    At least one cooling fan has failed

    Likely cause
    Fan malfunction or obstruction
    What to do
    Check and replace faulty fan; ensure no obstructions are present
  • Grid reverse sequencewarningCall your installer
    Manual (PDF)

    AC grid reverse sequence detected

    Likely cause
    Incorrect wiring of AC grid connections
    What to do
    Check wiring connections; correct if necessary
  • Soft start failurewarningCall your installer
    Manual (PDF)

    Soft start of the device failed

    Likely cause
    Internal component fault
    What to do
    Contact installer for diagnosis
  • The inverter is over-temperaturewarningCall your installer
    Manual (PDF)

    Inverter temperature is too high

    Likely cause
    Inadequate cooling or high operational load
    What to do
    Check cooling systems; reduce load or allow cooling period

More Eaton Power Quality (Shanghai) Co Ltd inverters

93PCS 250 (AS4777-2 2020)

250 kW · 3φ

93PCS 500 (AS4777-2 2020)

500 kW · 3φ

93PCS 125 (AS4777-2 2020)

125 kW · 3φ

93PCS 630 (AS4777-2 2020)

630 kW · 3φ

View all Eaton Power Quality (Shanghai) Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?