Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Hinen
  4. H10000H-EU

Hybrid inverter · Hinen · CEC approved December 2024

Hinen H10000H-EU

CEC listing: H10000H-EU (AS4777-2 2020)

A 10 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
10kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

H10000H-EU: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
10kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Dongguan Hinen New Energy Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Hinen H10000H-EU, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5.12 kW
DC input & MPPT
MPPT trackers2
Physical
Weight45 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
AC breaker30 A

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
11 Dec 2024
Approval expiry
11 Dec 2027
Status
Active
Listed for STCs
Yes

About Hinen

Years on the CEC list
2 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
33
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
42.5 kWh
Annual yield
15,513 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.hinen.com
2 years on the CEC list

How it compares

The Hinen H10000H-EU against the closest-power inverters from other brands.

Specification
Hinen H10000H-EUHinen
Energizer Force 10.0HS+Energizer
Energizer Force 10.0HT+Energizer
Rated power?10 kW10 kW10 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetOpens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guideOpens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Hinen H10000H-EU

Hinen offers a 10-year warranty covering defects in materials and workmanship for specified battery systems. Exclusions include improper installation and failure to meet environmental conditions.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, damage due to force majeure, improper use, and any installation that does not comply with applicable safety regulations.
Environment limits
The ambient temperature during operation must not fall below -10 °C or exceed 50 °C.
Read the official warranty document (PDF)

Fault & error codes — Hinen H10000H-EU

From the install manual

26 documented

Showing 26 of 26. The official install manual is the authoritative source — always confirm before acting.

  • Error 108criticalCall your installer
    Manual (PDF)

    NTC Temperature too high

    Likely cause
    Inverter internal temperature is too high.
    What to do
    Check the temperature, normal restart the inverter. If the error persists, contact manufacturer.
  • Error 109criticalCall your installer
    Manual (PDF)

    Bus voltage abnormal

    Likely cause
    Bus voltage exceeds normal range.
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 110criticalCall your installer
    Manual (PDF)

    Communication fault

    Likely cause
    Faulty communication board wiring.
    What to do
    Check communication board wiring and restart inverter. If error persists, contact manufacturer.
  • Error 113criticalCall your installer
    Manual (PDF)

    Over current protected by software

    Likely cause
    Current exceeds software limits
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 114criticalCall your installer
    Manual (PDF)

    Over current protected by software

    Likely cause
    Current exceeds software limits
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 116criticalCall your installer
    Manual (PDF)

    GFCI Module damage

    Likely cause
    Ground fault circuit interrupter module defect
    What to do
    Check the leakage current module and restart inverter. If error persists, contact manufacturer.
  • Error 121criticalCall your installer
    Manual (PDF)

    Buck boost current abnormal

    Likely cause
    Current balance issue
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 123criticalCall your installer
    Manual (PDF)

    BUS balance current abnormal

    Likely cause
    Current not balanced
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 124criticalCall your installer
    Manual (PDF)

    DCAC soft abnormal

    Likely cause
    Soft component issue
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 206criticalCall your installer
    Manual (PDF)

    Leakage current too high

    Likely cause
    Unacceptable ground fault current detected
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 207criticalCall your installer
    Manual (PDF)

    DCI too high

    Likely cause
    Input current exceeds tolerance
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 208criticalCall your installer
    Manual (PDF)

    AC active Power too high

    Likely cause
    Output power exceeds limits
    What to do
    Reduce EPS load and restart inverter. If error persists, contact manufacturer.
  • Error 210criticalCall your installer
    Manual (PDF)

    Phase difference too big

    Likely cause
    Imbalance in phase load
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 300criticalCall your installer
    Manual (PDF)

    EPS OP Short Fault

    Likely cause
    Short circuit detected in EPS port
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 304criticalCall your installer
    Manual (PDF)

    EPS port voltage abnormality

    Likely cause
    Electrical fault at EPS.
    What to do
    Check wiring of EPS port and restart inverter. If error persists, contact manufacturer.
  • Error 401criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value

    Likely cause
    Voltage exceeds rated values
    What to do
    Disconnect DC switch and check voltage. If error persists after restoring normal voltage, contact manufacturer.
  • Error 402criticalCall your installer
    Manual (PDF)

    PV Isolation Low

    Likely cause
    Poor grounding or connection of PV panels.
    What to do
    Check PV grounding and restart inverter. If error persists, contact manufacturer.
  • Error 403criticalCall your installer
    Manual (PDF)

    The DC input current is exceeding the maximum tolerable value

    Likely cause
    Input current too high.
    What to do
    Check panel connections and restart inverter. If error persists, contact manufacturer.
  • Error 500criticalCall your installer
    Manual (PDF)

    BMS Communication fault

    Likely cause
    Issues with battery management system communication.
    What to do
    Check 485 cable between SP and battery. If error persists, contact manufacturer.
  • Error 502criticalCall your installer
    Manual (PDF)

    Battery voltage low

    Likely cause
    Battery not holding charge or faulty.
    What to do
    Check battery voltage and connections. If error persists, contact manufacturer.
  • Error 503criticalCall your installer
    Manual (PDF)

    Battery Voltage High

    Likely cause
    Battery is overcharged.
    What to do
    Check battery conditions and restart inverter. If error persists, contact manufacturer.
  • Error 504criticalCall your installer
    Manual (PDF)

    Battery temperature out of specified range for charge or discharge

    Likely cause
    Temperature settings exceeded for battery.
    What to do
    Check battery temperature and conditions. If error persists, contact manufacturer.
  • Error 505criticalCall your installer
    Manual (PDF)

    Battery terminals reversed

    Likely cause
    Incorrect battery connections.
    What to do
    Check battery connections.
  • Error 506criticalCall your installer
    Manual (PDF)

    Battery terminal open (only for lithium battery)

    Likely cause
    Loose connections detected.
    What to do
    Inspect battery connections. If error persists, contact manufacturer.
  • Error 508criticalCall your installer
    Manual (PDF)

    Bat Relay Fault

    Likely cause
    Relay issues preventing proper operation.
    What to do
    Restart inverter. If error persists, contact manufacturer.
  • Error 125info
    Manual (PDF)

    The inverter is not turned on

    Likely cause
    Inverter is powered off
    What to do
    Ensure inverter is turned on via app and check emergency stop switch.

More Dongguan Hinen New Energy Technology Co Ltd inverters

A10000T (AS4777-2 2020)

9.999 kW · 3φ

A10000T-E (AS4777-2 2020)

9.999 kW · 3φ

H8000H-EU (AS4777-2 2020)

8 kW · 3φ

H12000H-EU (AS4777-2 2020)

12 kW · 3φ

A15000T (AS4777-2 2020)

15 kW · 3φ

A15000T-E (AS4777-2 2020)

15 kW · 3φ

View all Dongguan Hinen New Energy Technology Co Ltd inverters

More from Hinen

Other CEC-approved products from Hinen available in Australia.

Hinen Batteries

B14400-H

13.68 kWh · LFP

B14400-H x2

27.36 kWh · LFP

B14400-H x3

41.04 kWh · LFP

B14400-H x4

54.72 kWh · LFP

B14400-H x5

68.4 kWh · LFP

B14400-HW

13.68 kWh · LFP

View all Hinen batteries
View full Hinen manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?