Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE-S5 II

Hybrid inverter · Alpha ESS · CEC approved March 2026

Alpha ESS SMILE-S5 II

CEC listing: SMILE-S5 II (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-S5 II: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Alpha ESS Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Alpha ESS SMILE-S5 II, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Physical
Dimensions (H×W×D)250 × 640 × 745 mm
Weight75 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance200 mm
Side clearance150 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
5 Mar 2026
Approval expiry
12 Oct 2027
Status
Active
Listed for STCs
Yes

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-S5 II against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-S5 IIAlpha ESS
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manual and compliance certificatePDF, opens in a new tab

5-year inverter warranty

Alpha ESS SMILE-S5 II

This warranty covers the AlphaESS residential products for 5 years and ensures at least 80% capacity at year 10. Warranty claims can be made through the specified process.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, improper operation, and incorrect maintenance void the warranty.
Environment limits
Ambient temperature must not fall below -10°C or exceed 50°C and products must not be exposed to direct sunlight.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-S5 II

From the install manual

17 documented

Showing 17 of 17. The official install manual is the authoritative source — always confirm before acting.

  • 100007criticalCall your installer
    Manual (PDF)

    Insulation fault

    Likely cause
    Check installation environment; may require improved conditions.
    What to do
    Inspect and possibly disconnect solar panel strings to locate problems.
  • 100008criticalCall your installer
    Manual (PDF)

    GFCI fault

    Likely cause
    May indicate problems with insulation resistance; monitor closely.
    What to do
    Contact customer service for troubleshooting if it persists.
  • 100027criticalCall your installer
    Manual (PDF)

    Battery lose

    Likely cause
    Wiring issues or breaker is open; check connections.
    What to do
    Check battery wiring and BMS communication.
  • 100042criticalCall your installer
    Manual (PDF)

    Output short

    Likely cause
    Backup load is shorted; disconnect load and restart.
    What to do
    Disconnect the load and check the system.
  • 100043criticalCall your installer
    Manual (PDF)

    Output overload

    Likely cause
    Load connected exceeds maximum output; reduce load immediately.
    What to do
    Reduce load and restart the inverter.
  • 110029criticalCall your installer
    Manual (PDF)

    GFCI Alarm

    Likely cause
    Signals potential faults in the system; monitor closely.
    What to do
    Contact customer service if it persists.
  • 100005warning
    Manual (PDF)

    BUS OVP1

    Likely cause
    If it happens occasionally, the inverter can recover automatically, no processing is required.
    What to do
    Monitor the situation; if it persists, contact customer service.
  • 100010warningCall your installer
    Manual (PDF)

    Grid relay fault

    Likely cause
    Typically caused by short-term grid issues.
    What to do
    Monitor; if frequent, follow guidance for grid voltage issues.
  • 100012warning
    Manual (PDF)

    PV Reverse

    Likely cause
    PV string connections may be reversed.
    What to do
    Check the connections of PV strings.
  • 100025warningCall your installer
    Manual (PDF)

    Battery OVP

    Likely cause
    May indicate over-voltage during charging; check wiring and BMS communication.
    What to do
    Inspect wiring and potential loose connections.
  • 100026warningCall your installer
    Manual (PDF)

    Battery UVP

    Likely cause
    Check battery voltage and ensure all breakers are closed.
    What to do
    Verify the battery status and connections.
  • 100030warning
    Manual (PDF)

    Battery discharge OCP

    Likely cause
    Over-discharge situation; reduce backup load immediately.
    What to do
    Reduce load and restart the inverter.
  • 100038warningCall your installer
    Manual (PDF)

    Output DC over current

    Likely cause
    Short-term abnormality of the power grid can cause this fault.
    What to do
    Monitor; if persistent, contact customer service.
  • 100041warningCall your installer
    Manual (PDF)

    Output DC over voltage

    Likely cause
    Caused by a grid voltage issue, can often recover automatically.
    What to do
    Contact customer service for further check if it persists.
  • 100046warningCall your installer
    Manual (PDF)

    DC Input Disturbance

    Likely cause
    Usually recovers automatically if it happens occasionally.
    What to do
    Monitor for recurrences; if persistent, contact service.
  • 100052warningCall your installer
    Manual (PDF)

    Backup OVP

    Likely cause
    Generally recovers automatically, monitor closely.
    What to do
    If it continues, contact customer service.
  • 110030warning
    Manual (PDF)

    ISO Alarm

    Likely cause
    Restart the system to see if the fault persists.
    What to do
    Restart and monitor the system.

More Alpha ESS Co Ltd inverters

SMILE-B5 (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 II (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 III (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 IV (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 V (AS4777-2 2020)

5 kW · 1φ

SMILE-B5 VI (AS4777-2 2020)

5 kW · 1φ

View all Alpha ESS Co Ltd inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?