Battery inverter · Alpha ESS · CEC approved March 2026
CEC listing: SMILE-M5-B-INV (AS4777-2 2020)
A 5 kW single-phase battery inverter that is listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
Every figure on file for the Alpha ESS SMILE-M5-B-INV, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 5 kW |
| Physical | |
| Dimensions (H×W×D) | 390 × 620 × 240 mm |
| Weight | 19.5 kg |
| IP rating | IP65 |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| Top clearance | 200 mm |
| Side clearance | 150 mm |
| AC breaker | 40 A |
| Cable gauge | 6 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | Yes |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
alphaess.auThe Alpha ESS SMILE-M5-B-INV against the closest-power inverters from other brands.
| Specification | Alpha ESS SMILE-M5-B-INVAlpha ESS | Energizer FORCE 5.0HSEnergizer | Energizer Force 5.0HT+Energizer |
|---|---|---|---|
| Rated power? | 5 kW | 5 kW | 5 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Battery | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
The warranty covers the solar product for 10 years with a key exclusion for improper installation. Claims can be made through customer support.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 41 of 41. The official install manual is the authoritative source — always confirm before acting.
100007criticalCall your installerInsulation Fault
100008criticalCall your installerGFCI Fault
100025criticalCall your installerBattery Over Voltage
100026criticalCall your installerBattery Under Voltage
100027criticalCall your installerBattery Disconnection
100042criticalCall your installerOutput Short Circuit
100060criticalCall your installerDSP Self Check
100123criticalCall your installerDSP Communication Failure
110005criticalCall your installerBattery Stops Running Alarm
110027criticalCall your installerLN Reverse Alarm
110029criticalCall your installerGFCI Alarm
110030criticalCall your installerISO Alarm
110036criticalCall your installerFLASH ID Alarm
110039criticalCall your installerMachine Type Alarm
100005warningBus Over Voltage
100010warningGrid Relay Fault
100012warningPV Reverse Connection
100030warningBattery Over-Discharge
100038warningCall your installerOutput DC Over Current
100041warningCall your installerOutput DC Over Voltage
100043warningOutput Overload
100046warningCall your installerDC Input Disturbance
100052warningCall your installerBackup Over Voltage
100054warningCall your installerDC Bus Undervoltage
100058warningCall your installerAFCI Check Protect
100122warningEEPROM RW Failure
100145warning12V Auxiliary Power Fault
110004warningCall your installerDC Power Alarm
110006warningCall your installerOver Temperature Alarm
110014warningPV Over Voltage
110021warningCall your installerGrid Loss Alarm
110022warningCall your installerGrid Voltage Alarm
110023warningCall your installerGrid Frequency Alarm
110024warningCall your installer10 Min Grid Voltage Alarm
110034warningCall your installerFan Abnormal Alarm
110037warningCall your installerRead Flash Alarm
110040warningCall your installerInverter Voltage Low Alarm
110048warningCall your installerNo PV Input Alarm
110049warningInput Power Limit Alarm
110050warningCall your installerOutput Power Limit Alarm
110059warningCall your installerGrid Waveform Abnormal Alarm
SMILE-B5 (AS4777-2 2020)
5 kW · 1φ
SMILE-B5 II (AS4777-2 2020)
5 kW · 1φ
SMILE-B5 III (AS4777-2 2020)
5 kW · 1φ
SMILE-B5 IV (AS4777-2 2020)
5 kW · 1φ
SMILE-B5 V (AS4777-2 2020)
5 kW · 1φ
SMILE-B5 VI (AS4777-2 2020)
5 kW · 1φ
Other CEC-approved products from Alpha ESS available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.