Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE-M3.6-S-INV

Hybrid inverter · Alpha ESS · CEC approved June 2025

Alpha ESS SMILE-M3.6-S-INV

CEC listing: SMILE-M3.6-S-INV (AS4777-2 2020)

A 3.6 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
3.6kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-M3.6-S-INV: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.6kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Alpha ESS Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Alpha ESS SMILE-M3.6-S-INV, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Physical
Weight19.5 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance200 mm
Side clearance150 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
5 June 2025
Approval expiry
5 June 2028
Status
Active
Listed for STCs
Yes

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
15.3 kWh
Annual yield
5,585 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-M3.6-S-INV against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-M3.6-S-INVAlpha ESS
Energizer Force 3.6SEnergizer
Afore AF3.6K-SL-1Afore
Rated power?3.6 kW3.6 kW3.6 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridSolarHybrid
Battery readyYesNoYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Alpha ESS SMILE-M3.6-S-INV

The warranty covers the solar product for 10 years with a key exclusion for improper installation. Claims can be made through customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation or modification.
Environment limits
Operating temperatures exceeding 50°C.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-M3.6-S-INV

From the install manual

41 documented

Showing 41 of 41. The official install manual is the authoritative source — always confirm before acting.

  • 100007criticalCall your installer
    Manual (PDF)

    Insulation Fault

    Likely cause
    Wet installation environment or rainy weather.
    What to do
    Check environment and improve if needed; inspect each solar string.
  • 100008criticalCall your installer
    Manual (PDF)

    GFCI Fault

    Likely cause
    Insulation fault detected or inverter failure.
    What to do
    Refer to abnormal insulation guidance.
  • 100025criticalCall your installer
    Manual (PDF)

    Battery Over Voltage

    Likely cause
    Fault during initial installation or operation.
    What to do
    Check battery wiring and BMS communication.
  • 100026criticalCall your installer
    Manual (PDF)

    Battery Under Voltage

    Likely cause
    Battery voltage not within range, or switch issues.
    What to do
    Inspect battery status and connections.
  • 100027criticalCall your installer
    Manual (PDF)

    Battery Disconnection

    Likely cause
    Wiring issues or DC switch not closed.
    What to do
    Inspect battery connections and communication.
  • 100042criticalCall your installer
    Manual (PDF)

    Output Short Circuit

    Likely cause
    Indicates backup load issues or fault.
    What to do
    Disconnect load and restart.
  • 100060criticalCall your installer
    Manual (PDF)

    DSP Self Check

    Likely cause
    Internal issues requiring service.
    What to do
    Contact customer service for assistance.
  • 100123criticalCall your installer
    Manual (PDF)

    DSP Communication Failure

    Likely cause
    Communication loss in components.
    What to do
    Contact customer service for support.
  • 110005criticalCall your installer
    Manual (PDF)

    Battery Stops Running Alarm

    Likely cause
    Critical issue needing investigation.
    What to do
    Check battery health and contact customer service.
  • 110027criticalCall your installer
    Manual (PDF)

    LN Reverse Alarm

    Likely cause
    Check wiring for live and neutral switch.
    What to do
    Ensure correct wiring.
  • 110029criticalCall your installer
    Manual (PDF)

    GFCI Alarm

    Likely cause
    Confirmation of electrical faults.
    What to do
    Check electrical systems; contact support if needed.
  • 110030criticalCall your installer
    Manual (PDF)

    ISO Alarm

    Likely cause
    System issues needing review.
    What to do
    Continuous monitor with potential service needed.
  • 110036criticalCall your installer
    Manual (PDF)

    FLASH ID Alarm

    Likely cause
    System setup error requiring check.
    What to do
    Contact customer service for remedial actions.
  • 110039criticalCall your installer
    Manual (PDF)

    Machine Type Alarm

    Likely cause
    Firmware mismatch with physical model.
    What to do
    Contact customer support for clarification.
  • 100005warning
    Manual (PDF)

    Bus Over Voltage

    Likely cause
    Occasional occurrence, can recover automatically.
    What to do
    No action needed, monitor situation.
  • 100010warning
    Manual (PDF)

    Grid Relay Fault

    Likely cause
    Short-term grid abnormality.
    What to do
    No action needed if occasional; monitor and check if frequent.
  • 100012warning
    Manual (PDF)

    PV Reverse Connection

    Likely cause
    Incorrectly connected PV cables.
    What to do
    Reconnect cables correctly.
  • 100030warning
    Manual (PDF)

    Battery Over-Discharge

    Likely cause
    Backup load too high.
    What to do
    Reduce load and restart.
  • 100038warningCall your installer
    Manual (PDF)

    Output DC Over Current

    Likely cause
    Short-term grid abnormality.
    What to do
    Monitor and contact support if persistent.
  • 100041warningCall your installer
    Manual (PDF)

    Output DC Over Voltage

    Likely cause
    Short-term abnormality.
    What to do
    Monitor and contact support if persists.
  • 100043warning
    Manual (PDF)

    Output Overload

    Likely cause
    Backup load exceeds limit.
    What to do
    Reduce load and check connections.
  • 100046warningCall your installer
    Manual (PDF)

    DC Input Disturbance

    Likely cause
    Occasional occurrence.
    What to do
    Monitor and contact support if persists.
  • 100052warningCall your installer
    Manual (PDF)

    Backup Over Voltage

    Likely cause
    Occasional issue, inverter may recover automatically.
    What to do
    Monitor and contact if persists.
  • 100054warningCall your installer
    Manual (PDF)

    DC Bus Undervoltage

    Likely cause
    Occasionally occurs and may recover automatically.
    What to do
    Monitor; contact support if continues.
  • 100058warningCall your installer
    Manual (PDF)

    AFCI Check Protect

    Likely cause
    Needs restart to check fault persistency.
    What to do
    Restart system and monitor.
  • 100122warning
    Manual (PDF)

    EEPROM RW Failure

    Likely cause
    Issues after remote upgrade.
    What to do
    Monitor, no action required unless persists.
  • 100145warning
    Manual (PDF)

    12V Auxiliary Power Fault

    Likely cause
    Occasional fault that may recover automatically.
    What to do
    Monitor; check if issue persists.
  • 110004warningCall your installer
    Manual (PDF)

    DC Power Alarm

    Likely cause
    Grid over voltage condition.
    What to do
    Check grid voltage settings; contact service if needed.
  • 110006warningCall your installer
    Manual (PDF)

    Over Temperature Alarm

    Likely cause
    Humidity or exposure to high temperature.
    What to do
    Ensure ventilation; check ambient conditions.
  • 110014warning
    Manual (PDF)

    PV Over Voltage

    Likely cause
    Incorrect wiring or high temp conditions.
    What to do
    Check PV module setup.
  • 110021warningCall your installer
    Manual (PDF)

    Grid Loss Alarm

    Likely cause
    Short-term grid loss; may recover automatically.
    What to do
    Monitor; contact local power operator.
  • 110022warningCall your installer
    Manual (PDF)

    Grid Voltage Alarm

    Likely cause
    Check grid connection status.
    What to do
    Monitor voltage status; consult service.
  • 110023warningCall your installer
    Manual (PDF)

    Grid Frequency Alarm

    Likely cause
    Short-term grid anomaly; typically recovers.
    What to do
    Monitor; contact support if persists.
  • 110024warningCall your installer
    Manual (PDF)

    10 Min Grid Voltage Alarm

    Likely cause
    Sliding average voltage exceeds standard.
    What to do
    Check voltage settings and adjustments.
  • 110034warningCall your installer
    Manual (PDF)

    Fan Abnormal Alarm

    Likely cause
    Fan failures or slow operation; check functionality.
    What to do
    Inspect and replace if necessary.
  • 110037warningCall your installer
    Manual (PDF)

    Read Flash Alarm

    Likely cause
    Persistent issue requiring investigation.
    What to do
    Monitor conditions; contact service if continues.
  • 110040warningCall your installer
    Manual (PDF)

    Inverter Voltage Low Alarm

    Likely cause
    Low light conditions or short circuits.
    What to do
    Monitor and check PV connections.
  • 110048warningCall your installer
    Manual (PDF)

    No PV Input Alarm

    Likely cause
    Occasional occurrence; check circuits.
    What to do
    Inspect conditions of PV setup.
  • 110049warning
    Manual (PDF)

    Input Power Limit Alarm

    Likely cause
    Low light or operational limitations.
    What to do
    Typically no action required; monitor.
  • 110050warningCall your installer
    Manual (PDF)

    Output Power Limit Alarm

    Likely cause
    Reset system to check fault clarity.
    What to do
    Restart system to clear issues.
  • 110059warningCall your installer
    Manual (PDF)

    Grid Waveform Abnormal Alarm

    Likely cause
    Short-term grid anomalies.
    What to do
    Monitor and contact service if frequently recorded.

More Alpha ESS Co Ltd inverters

SMILE-G3-S3.6-INV (AS4777-2 2020)

3.68 kW · 1φ

SMILE-B3-PLUS (AS4777-2 2020)

3 kW · 1φ

SMILE-B3-PLUS II (AS4777-2 2020)

3 kW · 1φ

SMILE-B3-PLUS III (AS4777-2 2020)

3 kW · 1φ

SMILE-B3-PLUS IV (AS4777-2 2020)

3 kW · 1φ

SMILE-B3-PLUS V (AS4777-2 2020)

3 kW · 1φ

View all Alpha ESS Co Ltd inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?