Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Xian Golden Stone Electric Technology
  4. MA1000K060

Battery inverter · Xian Golden Stone Electric Technology · CEC approved March 2026

Xian Golden Stone Electric Technology MA1000K060

CEC listing: MA1000K060 (AS4777-2 2020)

A 60 kW three-phase battery inverter.

Rated power
60kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter

Commercial-scale inverter

At 60 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
60kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
5yr
How long Xian Golden Stone Electric Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Xian Golden Stone Electric Technology MA1000K060, by section.

Full datasheet, by section
SpecificationValue
Physical
Operating temperature-30°C to 50°C
Installation requirements
Top clearance800 mm
Side clearance800 mm
Cable gauge70 mm²
Earthing methodPE terminal
DNSP pre-approvalNo
Estimated install time10 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
27 Mar 2026
Approval expiry
17 Nov 2028
Status
Active
Listed for STCs
Yes

About Xian Golden Stone Electric Technology

Australian office
Not verified
Category
Unknown
CEC-approved inverters
2
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

0 years on the CEC list

How it compares

The Xian Golden Stone Electric Technology MA1000K060 against the closest-power inverters from other brands.

Specification
Xian Golden Stone Electric Technology MA1000K060Xian Golden Stone Electric Technology
Solplanet ASW60K-LT-G3Solplanet
FoxESS H3-60-PlusFoxESS
Rated power?60 kW60 kW60 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeBatterySolarHybrid
Battery readyYesNoYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Xian Golden Stone Electric Technology MA1000K060

This warranty covers defects for 5 years. It excludes issues from non-accredited installations. Claims can be made by contacting support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modification, tampering.
Environment limits
Derating above 45°C
Read the official warranty document (PDF)

Fault & error codes — Xian Golden Stone Electric Technology MA1000K060

From the install manual

23 documented

Showing 23 of 23. The official install manual is the authoritative source — always confirm before acting.

  • AC_GridPhaseSeque_FaultcriticalCall your installer
    Manual (PDF)

    Grid phase sequence fault

    Likely cause
    Incorrect phase sequence detected
    What to do
    Check phase connections and correct as necessary.
  • AC_MainContactor_FailurecriticalCall your installer
    Manual (PDF)

    Main contactor permanent failure

    Likely cause
    Failure of the main contactor in the inverter
    What to do
    Contact a technician for inspection and repair.
  • AC_NoUtility_FaultcriticalCall your installer
    Manual (PDF)

    No AC utility fault

    Likely cause
    Loss of AC input voltage
    What to do
    Check the power supply; if the issue persists, contact support.
  • AC_OverFreq_FaultcriticalCall your installer
    Manual (PDF)

    AC over frequency fault

    Likely cause
    Frequency exceeding upper limit
    What to do
    Wait for frequency to reduce; if persistent, contact support.
  • AC_SlaveContactor_FailurecriticalCall your installer
    Manual (PDF)

    Auxiliary contactor permanent failure

    Likely cause
    Failure of the auxiliary contactor
    What to do
    Contact a technician for inspection and repair.
  • AC_UnderFreq_FaultcriticalCall your installer
    Manual (PDF)

    AC under frequency fault

    Likely cause
    Frequency falling below lower limit
    What to do
    Wait for frequency to increase; if persistent, contact support.
  • AC_UV_OverVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC UV over voltage fault

    Likely cause
    Voltage exceeding upper limit on UV phase
    What to do
    Check and rectify the voltage condition.
  • AC_UV_UnderVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC UV under voltage fault

    Likely cause
    Voltage dropping below lower limit on UV phase
    What to do
    Check and rectify the voltage condition.
  • AC_Volt_UNbalance_FaultcriticalCall your installer
    Manual (PDF)

    AC voltage unbalance fault

    Likely cause
    Uneven voltage across phases
    What to do
    Investigate and balance system voltage.
  • AC_VW_OverVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC VW over voltage fault

    Likely cause
    Voltage exceeding upper limit on VW phase
    What to do
    Check and rectify the voltage condition.
  • AC_VW_UnderVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC VW under voltage fault

    Likely cause
    Voltage dropping below lower limit on VW phase
    What to do
    Check and rectify the voltage condition.
  • AC_WU_OverVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC WU over voltage fault

    Likely cause
    Voltage exceeding upper limit on WU phase
    What to do
    Check and rectify the voltage condition.
  • AC_WU_UnderVolt_FaultcriticalCall your installer
    Manual (PDF)

    AC WU under voltage fault

    Likely cause
    Voltage dropping below lower limit on WU phase
    What to do
    Check and rectify the voltage condition.
  • BMS_Communication_FaultcriticalCall your installer
    Manual (PDF)

    BMS communication fault

    Likely cause
    Failure in communication with the battery management system
    What to do
    Check connections or contact support.
  • BMS_FaultcriticalCall your installer
    Manual (PDF)

    Battery management system fault

    Likely cause
    Fault detected in the battery management system
    What to do
    Contact the battery supplier for support.
  • Bypass_Communication_FaultcriticalCall your installer
    Manual (PDF)

    Bypass cabinet communication fault

    Likely cause
    Loss of communication with the bypass cabinet
    What to do
    Check connections or contact support.
  • Converter_L_OCP_FaultcriticalCall your installer
    Manual (PDF)

    Converter inductor over current fault

    Likely cause
    Current exceeding limits in the converter inductor
    What to do
    Contact a technician for inspection and repair.
  • EEPROM_Read_FailurecriticalCall your installer
    Manual (PDF)

    EEPROM read permanent failure

    Likely cause
    Failure in reading data from EEPROM
    What to do
    Contact support for assistance with EEPROM issues.
  • EEPROM_Write_FailurecriticalCall your installer
    Manual (PDF)

    EEPROM write permanent failure

    Likely cause
    Failure in writing data to EEPROM
    What to do
    Contact support for assistance with EEPROM issues.
  • IGBT_Converter_FaultcriticalCall your installer
    Manual (PDF)

    IGBT converter fault

    Likely cause
    Fault in the IGBT module used for conversion
    What to do
    Contact a technician for inspection and repair.
  • IGBT_FailurecriticalCall your installer
    Manual (PDF)

    IGBT permanent failure

    Likely cause
    Fault in the IGBT module
    What to do
    Contact a qualified technician for repair or replacement.
  • PBD250_Communication_FaultcriticalCall your installer
    Manual (PDF)

    PBD250 communication fault

    Likely cause
    Loss of communication with the PBD250
    What to do
    Check connections or contact support.
  • Smoke_alarm_FaultcriticalCall your installer
    Manual (PDF)

    Smoke alarm fault

    Likely cause
    Smoke detected within the inverter
    What to do
    Shut down the system and investigate the cause immediately.

More Xian Golden Stone Electric Technology Co Ltd inverters

MA1000K030 (AS4777-2 2020)

30 kW · 3φ

View all Xian Golden Stone Electric Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?