Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Xiamen Well Energy Technology
  4. CGS S5.0 6H6

Hybrid inverter · Xiamen Well Energy Technology · CEC approved September 2026

Xiamen Well Energy Technology CGS S5.0 6H6

CEC listing: CGS S5.0 6H6 (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready.

Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

CGS S5.0 6H6: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
98.5%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Xiamen Well Energy Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Xiamen Well Energy Technology CGS S5.0 6H6, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.5%
Physical
Dimensions (H×W×D)629 × 647 × 252 mm
Weight45 kg
IP ratingIP65
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker20 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
29 Sept 2026
Approval expiry
31 Dec 2027
Status
Active
Listed for STCs
Yes

About Xiamen Well Energy Technology

Australian office
Not verified
Category
Budget
CEC-approved inverters
16
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

0 years on the CEC list

How it compares

The Xiamen Well Energy Technology CGS S5.0 6H6 against the closest-power inverters from other brands.

Specification
Xiamen Well Energy Technology CGS S5.0 6H6Xiamen Well Energy Technology
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?98.5%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Xiamen Well Energy Technology CGS S5.0 6H6

SUNGROW offers a 10-year warranty against defects for residential products, excluding damages from improper installations. To make a claim, contact your installer with proof of purchase.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Improper installation, neglect, unauthorized modifications, non-certified personnel.
Environment limits
Use of product near the sea or in a corrosive environment.
Read the official warranty document (PDF)

Fault & error codes — Xiamen Well Energy Technology CGS S5.0 6H6

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • DSP-B-FAULTcriticalCall your installer
    Manual (PDF)

    Communication failure between main and slave DSP

    Likely cause
    Fault in internal communication systems
    What to do
    Restart the inverter; if the fault remains, contact an installer.
  • ILeak-PRO 01/02/03/04criticalCall your installer
    Manual (PDF)

    Leakage current protection activated

    Likely cause
    Potential shorts in AC or DC connections
    What to do
    Inspect AC and DC connections for faults and ensure integrity; contact installer if necessary.
  • INI-FAULTcriticalCall your installer
    Manual (PDF)

    Initialization system fault

    Likely cause
    System unable to start up due to internal errors
    What to do
    Restart inverter. If the issue persists, contact the installer.
  • OV-DC01/02/03/04criticalCall your installer
    Manual (PDF)

    Over DC voltage

    Likely cause
    Exceeding voltage limits from the PV string
    What to do
    Reduce the number of panels in series or contact installer for assistance.
  • PVISO-PROcriticalCall your installer
    Manual (PDF)

    Earth fault detected on the PV side

    Likely cause
    Isolation fault in the PV strings or connections
    What to do
    Identify and resolve the earth fault. Do not attempt to generate power until the fault is fixed.
  • Screen OFF with DC appliedcriticalCall your installer
    Manual (PDF)

    Inverter internally damaged

    Likely cause
    A potential internal fault of the inverter due to incorrect operation
    What to do
    Wait for solar irradiance to decrease and follow the safe shutdown procedure, then contact installer.
  • OV-G-F01/02warning
    Manual (PDF)

    Over grid frequency

    Likely cause
    Grid frequency settings too high
    What to do
    Adjust the protection limit if allowed by the electrical company.
  • OV-G-V01/02/03/04warningCall your installer
    Manual (PDF)

    Over grid voltage

    Likely cause
    Resistance of AC cable is too high or incorrect voltage settings
    What to do
    Change to a larger size grid cable or adjust the protection limit if allowed.
  • OV-TEMwarning
    Manual (PDF)

    Over temperature

    Likely cause
    Inadequate ventilation or excessive heat exposure
    What to do
    Check inverter's surroundings for proper ventilation and shade from direct sunlight.
  • UN-G-F01/02warning
    Manual (PDF)

    Under grid frequency

    Likely cause
    Grid frequency settings too low
    What to do
    Adjust the protection limit if allowed by the electrical company.
  • UN-G-V01/02warning
    Manual (PDF)

    Under grid voltage

    Likely cause
    Low voltage conditions on the grid
    What to do
    Adjust the protection limit if allowed by the electrical company.

More Xiamen Well Energy Technology Co Ltd inverters

CGS S5.0 6H1 (AS4777-2 2020)

5 kW · 1φ

CGS S5.0 6H2 (AS4777-2 2020)

5 kW · 1φ

CGS S5.0 6H3 (AS4777-2 2020)

5 kW · 1φ

CGS S5.0 6H4 (AS4777-2 2020)

5 kW · 1φ

CGS S5.0 6H5 (AS4777-2 2020)

5 kW · 1φ

CGS S5.0 6H7 (AS4777-2 2020)

5 kW · 1φ

View all Xiamen Well Energy Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?